FUJIFILM

Primary DI
04547410513790
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
EP-8000
Device description
- The EP-8000 is an endoscopic processor with an integrated light source that is intended to provide illumination, process electronic signals transmitted from a video endoscope and enable image recording.- This product can be used in combination with compatible medical endoscope, a monitor, a recorder and various peripherals.- It supplies air through the endoscope, for obtaining clear visualization and is used for endoscopic observation, diagnosis and treatment.- BLI (Blue Light Imaging), LCI (Linked Color Imaging), ACI (Amber-red Color Imaging) and FICE (Flexible spectral-Imaging Color Enhancement) are adjunctive tools for gastrointestinal endoscopic examinations which can be used to supplement Fujifilm white light endoscopy.BLI, LCI, ACI and FICE are not intended to replace histopathological sampling as a means of diagnosis.- BLI, LCI, ACI and FICE are not intended for bronchoscopic examination.
Published
2025-05-31
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
EOQBronchoscope (Flexible Or Rigid)
FDSGastroscope And Accessories, Flexible/Rigid
FETEndoscopic Video Imaging System/Component, Gastroenterology-Urology
NTNLed Light Source
NWBEndoscope, Accessories, Narrow Band Spectrum
PEAEndoscope, Accessories, Image Post-Processing For Color Enhancement

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
EOQBronchoscope (Flexible Or Rigid)Ear, Nose, Throat2
FDSGastroscope And Accessories, Flexible/RigidGastroenterology, Urology2
FETEndoscopic Video Imaging System/Component, Gastroenterology-UrologyGastroenterology, Urology2
NTNLed Light SourceGastroenterology, Urology2
NWBEndoscope, Accessories, Narrow Band SpectrumGastroenterology, Urology2
PEAEndoscope, Accessories, Image Post-Processing For Color EnhancementGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K243260000
K244017000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K243260000FUJIFILM Processor EP-8000; FUJIFILM Endoscope Model EG-860RFujifilm Corporation2025-04-11FET
K244017000FUJIFILM Endoscope Model EB-710P; FUJIFILM Processor EP-8000Fujifilm Corporation2025-06-13EOQ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04547410513790PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04547410513790045474105137904547410513790

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic video image processing/light source systemA mains electricity (AC-powered) unit/assembly that, when used with an appropriate endoscope (not included), is designed to both: 1) produce a source of cold light for endoscopic imaging; and 2) receive and process electronic video image signals sent from the endoscope/endoscopic video camera. It may additionally include image recording features and an image display monitor, however it does not include features to steer, propel or otherwise control the movement of the endoscope.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00no dew condensation
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
Hydrogen Peroxide

Regulatory Flags#

DUNS number
713565195
Device count
1
Serial number
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
04573596202210APERTO LucentMR-QFC-82NFlexible Body coil N(M) MR-QFC-82N for APERTO Luce2026-05-22
04573596202227APERTO LucentMR-QFC-83NFlexible Body coil N(L) MR-QFC-83N for APERTO Luce2026-05-22
04573596200704APERTO LucentAPERTO LucentAPERTO Lucent2024-09-19
04547410334494Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B15-2016-09-16
04547410334500Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B20-2016-09-16
04547410334517Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B25-2016-09-16
04547410334524Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B30-2016-09-16
04547410334531Fujifilm Diathermic Slitter (FlushKnife)DK2618J -N10-2016-09-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
10810068810841MONARCH™ Navigation SensorsAuris Health, Inc.EOQ2026-05-27
10810068810858MONARCH™ ControllerAuris Health, Inc.EOQ2026-05-27
00840432200063CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200117CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200308CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200315CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00840432200322CystoView™Verathon Medical (Canada) ULCFET2026-05-15
00817325025003iVisionMEDIMAX TECH INC.NTN2026-04-30
00856571007265EasyPath RF Introducer SheathBRONCUS MEDICAL INC.EOQ2026-04-23
00850048825086Galaxy System (Cart) - RefurbishedNoah Medical CorporationEOQ2025-10-25
04048551418123n.a.Karl Storz GmbH & Co. KGFET2025-08-11
10810068810896Monarch Bronchscope 2.0/Monarch Platform (P2), RefurbishedAuris Health, Inc.EOQ2025-08-04
10810068811169Monarch Platform, Bronchoscopy 4.1, RefurbishedAuris Health, Inc.EOQ2025-08-04
04250480104262N/ASCHÖLLY FIBEROPTIC GmbHFET2025-06-11
10810068811510Monarch™ Laptop P17 Software v4.1.1Auris Health, Inc.EOQ2025-06-04
10810068811527Monarch™ Laptop P16 Software v4.1.1Auris Health, Inc.EOQ2025-06-04
10810068810988Monarch Platform, Bronchoscopy 4.1Auris Health, Inc.EOQ2025-03-03
10810068810605Monarch™ Laptop P17 Software v4.1.0Auris Health, Inc.EOQ2025-03-03
10810068810612Monarch™ Laptop P16 Software v4.1.0Auris Health, Inc.EOQ2025-03-03
04048551425695n.a.Karl Storz GmbH & Co. KGFET2024-12-20
04250480101704NASCHÖLLY FIBEROPTIC GmbHFET2024-12-03
04048551436271n.a.Karl Storz GmbH & Co. KGFET2024-11-28
04048551436240n.a.Karl Storz GmbH & Co. KGFET2024-10-18
00810024670260Dragonfly Pancreaticobiliary Scope and Instrument Channel CapsCENTERPOINT SYSTEMS LLCNTN2024-07-22
00850006222322Pathfinder® CR SystemNEPTUNE MEDICAL INC.FDS2024-07-09
10810068810834Bronchoscope Fluidics TubingAuris Health, Inc.EOQ2024-05-05
10810068810865Monarch BronchoscopeAuris Health, Inc.EOQ2024-05-05
10810068810872Bronchoscope Sheath ValveAuris Health, Inc.EOQ2024-05-05
07613327616682SPYSTRYKER CORPORATIONNWB2024-02-27
07613327616699SPYSTRYKER CORPORATIONNWB2024-02-27