NA

Primary DI
04055207063392
Brand
NA
Company
Richard Wolf GmbH
Model
2260003
Catalog number
2260003
Device description
HF SURGERY GENERATOR 400KHZ for Urology, Gynecology, Surgery, for the connection of monopolar and bipolar accessories, international version for USA, monopolar connection Bovie, 3-pin, 4mm plug, bipolar connection, Erbe, Valleylab, touch screen, color display, compatible with core nova, connection socket for neutral electrode cable international, U: 100-240VAC, 50/60Hz, Dim. (wxhxd) 300x159x416
Published
2023-07-07
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, cutting & coagulation & accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K230194000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K230194000HF Surgery Generator 400KHZRichard Wolf Medical Instruments Corporation2023-03-22GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04055207063392PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04055207063392040552070633924055207063392

GMDN Terms#

Term, Definition table
TermDefinition
Electrosurgical system generatorAn electrically-powered component of a electrosurgical system intended to generate radio-frequency (RF) electrical current for subsequent cutting and coagulation of soft tissues during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system generator). It includes controls, may include an integrated surgical plume (smoke) suction unit, and is intended to be connected via a cable to an electrosurgical handpiece and electrode (neither of these are included); it is not intended for inert gas-enhanced electrosurgery.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+497043350info@richard-wolf.com

Regulatory Flags#

DUNS number
315304071
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04055207056585HIGHFLOW223560122356012017-07-21
04055207056592HIGHFLOW223561122356112017-07-21
04055207026526ERAGON BIPOLAR83930031839300312016-09-27
04055207026533ERAGON BIPOLAR83930032839300322016-09-27
04055207026540ERAGON BIPOLAR83930033839300332016-09-27
04055207026557ERAGON BIPOLAR83930034839300342016-09-27
04055207026564ERAGON BIPOLAR83930035839300352016-09-23
04055207026588ERAGON BIPOLAR83930041839300412016-09-27
04055207026724ERAGON BIPOLAR83930921839309212016-09-27
04055207033876ERAGON BIPOLAR8393001028393001022016-09-27
04055207055540ERAGON BIPOLAR83930037839300372016-09-27
04055207066805NA880888.082026-06-02
04055207007709NA180118.012026-05-29
04055207007723RIWO880388.032026-05-29
04055207007747NA890089.002026-05-29
04055207007792NA890589.052026-05-29
04055207007815NA890989.092026-05-29
04055207007839NA892089.202026-05-29
04055207008409NA8917189.1712026-05-29
04055207038505RIWO880088.002026-05-29

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776408718MillenniumAvalign Technologies, Inc.GEI2026-08-03
00190776422677MillenniumAvalign Technologies, Inc.GEI2026-08-03
00190776422820MillenniumAvalign Technologies, Inc.GEI2026-08-03
B382SD5657815600Surgical DirectSurgical Direct, Inc.GEI2026-08-03
00190776407445MillenniumAvalign Technologies, Inc.GEI2026-07-31
00190776422332MillenniumAvalign Technologies, Inc.GEI2026-07-31
00190776422516MillenniumAvalign Technologies, Inc.GEI2026-07-31
00198506092640ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-29
00198506093562ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-29
07613327688849MalisSTRYKER CORPORATIONGEI2026-07-29
07613327688856MalisSTRYKER CORPORATIONGEI2026-07-29
07613327688979MalisSTRYKER CORPORATIONGEI2026-07-29
07613327688986MalisSTRYKER CORPORATIONGEI2026-07-29
08800020110688INTRAGen HandpieceJeisys Medical Inc.GEI2026-07-29
B354OSRP80Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
B354OSRP81Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
B354OSRP82Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
B354OSRP83Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
B354OSRP84Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
B354OSRP85Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
B354OSRP89Retrieval Pouch (Multi Deploy) 8 mmORANGE SURGICAL INSTRUMENTS, LLCGEI2026-07-29
00190776407285MillenniumAvalign Technologies, Inc.GEI2026-07-28
00190776407292MillenniumAvalign Technologies, Inc.GEI2026-07-28
00198506092770ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28
00198506092886ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28
00198506092893ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28
00198506092909ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28
00198506092916ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28
00198506092954ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28
00198506092961ELMED INCORPORATEDELMED INCORPORATEDGEI2026-07-28