NPS2 Nihon Kohden BSM 8800

Primary DI
04057834024739
Brand
NPS2 Nihon Kohden BSM 8800
Company
RAUMEDIC AG
Model
091676-001
Published
2016-08-18
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GWMDevice, Monitoring, Intracranial Pressure

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GWMDevice, Monitoring, Intracranial PressureNeurology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04057834024739PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04057834024739040578340247394057834024739

GMDN Terms#

Term, Definition table
TermDefinition
Intracranial pressure monitor calibrator/cableA device intended to generate a reference baseline for the standardization of intracranial pressure (ICP) readings and to transfer the readings from an intracranial catheter (e.g., intracerebral sensor catheter) to an intracranial pressure monitor. It consists of a small unit with input and output cables to make electrical connections between a catheter connection cable and the patient monitor. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity15 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+4992523590hospitalcare@raumedic.com
+18886470070hospitalcare@raumedic.com

Regulatory Flags#

DUNS number
332785323
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04057834023541Tunneling KIT CH8090516-0012025-12-08
04057834090468Tunneling KIT CH12090727-0012025-12-08
04057834026115NEUROVENT-P092946-0032025-12-05
04057834082845NEUROVENT092956-0032025-12-05
04057834082876NEUROVENT-IFD-S091678-0032025-12-05
04057834082883NEUROVENT-IFD-R095317-0032025-12-05
04057834082906NEUROVENT-TEMP-IFD-S094288-0032025-12-05
04057834082913NEUROVENT-TEMP-IFD-R095327-0032025-12-05
04057834082920NEUROVENT-P-TEMP094268-0032025-12-05
04057834082937NEUROVENT-TEMP094278-0032025-12-05
04057834082968NEUROVENT-PTO095008-0032025-12-05
04057834083026NEUROVENT-PTO 2L095108-0032025-12-05
04057834088410NEUROVENT-PX091580-0032025-12-05
04057834097559BOLT-DRILL KIT CH5091888-0032025-12-05
04057834097566BOLT-DRILL KIT CH9091898-0032025-12-05
04057834097610BOLT-DRILL KIT PTO092380-0032025-12-05
04057834023534Spliceable Tunneling Sleeve CH8090506-0022016-08-18
04057834023831Spliceable Tunneling Sleeve CH12090717-0012016-08-18
04057834024074NPS2 Datex Ohmeda090924-0012016-08-18
04057834024722DRILL KIT CH9091668-0022016-08-18

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07908398200008BraincareBRAINCARE DESENVOLVIMENTO E INOVACAO TECNOLOGICA SAGWM2026-05-08
00850013266272IRRAflow Cranial Access BoltClearpoint Neuro, Inc.GWM2025-07-24
00763000281243Exacta Pole Clamp with laser levelMEDTRONIC PS MEDICAL, INC.GWM2025-02-17
00763000281229Exacta Pole Clamp with laser levelMEDTRONIC PS MEDICAL, INC.GWM2025-02-16
00763000467401NAMEDTRONIC PS MEDICAL, INC.GWM2024-06-01
00763000406073BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-03-31
20763000467344NAMEDTRONIC PS MEDICAL, INC.GWM2024-03-01
20763000467351NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
20763000467382NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
20763000467399NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000406080NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000431259BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000529307BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000529369BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000572877BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-25
00850013266203IRRAflow Tube SetClearpoint Neuro, Inc.GWM2023-11-02
00763000624774Duet®MEDTRONIC PS MEDICAL, INC.GWM2022-03-10
00763000624781Duet®MEDTRONIC PS MEDICAL, INC.GWM2022-03-10
00763000624798Duet®MEDTRONIC PS MEDICAL, INC.GWM2022-03-10
00763000428723Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428747Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428754Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428761Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428778Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000431273Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-13
20763000431307N/AMEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000395971Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000395988N/AMEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000406004Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000406011Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-07