Hermann Medizintechnik GmbH

Primary DI
04059453007407
Brand
Hermann Medizintechnik GmbH
Company
Hermann Medizintechnik GmbH
Model
H43-533-731
Device description
Grasping forceps serrated, Ø5mm, WL 330mm, double action jaw, shaft insulated, plastic handle /ratchet deactivatable, HF-connection, detachable
Published
2021-07-21
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
GCJLaparoscope, general & plastic surgery

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K051610000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K051610000HANS HERMANN LAPAROSCOPES AND ACCESSORIESHans Hermann GmbH2005-07-29GCJ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04059453007407PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04059453007407040594530074074059453007407

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic electrosurgical handpiece/electrode, monopolar, reusableAn electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and requires a patient contact return electrode to complete the circuit. This is a reusable device.

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+49746299670info@hermann-medizintechnik.de

Regulatory Flags#

DUNS number
324868165
Device count
1
Lot or batch
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04059453116635Hermann Medizintechnik GmbHH142-810102026-08-25
04059453095022Hermann Medizintechnik GmbHH132-635092026-07-27
04059453084217Hermann Medizintechnik GmbHH124-144132026-07-16
04059453127471Hermann Medizintechnik GmbHH146-455062026-07-16
04059453127891Hermann Medizintechnik GmbHH146-471072026-07-16
04059453133809Hermann Medizintechnik GmbHH152-272222026-07-16
04059453072832Hermann Medizintechnik GmbHH112-447212026-07-13
04059453162618Hermann Medizintechnik GmbHH-585.2026-07-13
04059453161574Hermann Medizintechnik GmbHH-5062026-06-03
04059453162762Hermann Medizintechnik GmbHH-594HM2026-05-29
04059453163318Hermann Medizintechnik GmbHH65-05402026-05-29
04059453140418Hermann Medizintechnik GmbHH168-430002026-05-21
04059453078087Hermann Medizintechnik GmbHH118-280082026-05-12
04059453078810Hermann Medizintechnik GmbHH118-348222026-05-12
04059453122254Hermann Medizintechnik GmbHH144-280082026-05-12
04059453062581Hermann Medizintechnik GmbHH108-218182026-04-27
04059453076052Hermann Medizintechnik GmbHH118-127112026-04-27
04059453158444Hermann Medizintechnik GmbHH-329HM2026-04-07
04059453158611Hermann Medizintechnik GmbHH-333HM2026-04-07
04059453163783Hermann Medizintechnik GmbHH-661HM 2026-03-31

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00724995268312Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268329Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268336Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268343Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268350Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268374Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268381Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268398Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268404Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268411Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268428Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268435Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268442Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268459Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268466Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268473Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268480Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268497Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268503Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269517Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269531Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269548Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269555Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269562Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269579Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269593Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
04995047072416CuratOREIZO CORPORATIONGCJ2026-09-25
00190776432348MillenniumAvalign Technologies, Inc.GCJ2026-09-24
00190776432386MillenniumAvalign Technologies, Inc.GCJ2026-09-24
00190776432416MillenniumAvalign Technologies, Inc.GCJ2026-09-24