Hermann Medizintechnik GmbH

Primary DI
04059453056535
Brand
Hermann Medizintechnik GmbH
Company
Hermann Medizintechnik GmbH
Model
H50-050-000
Device description
Telescope bridge
Published
2026-03-30
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
GCJLaparoscope, General & Plastic Surgery

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K051610000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K051610000HANS HERMANN LAPAROSCOPES AND ACCESSORIESHans Hermann GmbH2005-07-29GCJ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04059453056535PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04059453056535040594530565354059453056535

GMDN Terms#

Term, Definition table
TermDefinition
Laparoscopic access cannula, reusableA single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is often provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. It is available in a variety of dimensions and/or designs. This is a reusable device.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
324868165
Device count
1
Lot or batch
true
Expiration date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04059453158284Hermann Medizintechnik GmbHH-322HM2026-09-30
04059453158307Hermann Medizintechnik GmbHH-323HM2026-09-30
04059453161765Hermann Medizintechnik GmbHH-513HMST2026-09-30
04059453052568Hermann Medizintechnik GmbHH108-161232026-09-28
04059453116635Hermann Medizintechnik GmbHH142-810102026-08-25
04059453095022Hermann Medizintechnik GmbHH132-635092026-07-27
04059453084217Hermann Medizintechnik GmbHH124-144132026-07-16
04059453127471Hermann Medizintechnik GmbHH146-455062026-07-16
04059453127891Hermann Medizintechnik GmbHH146-471072026-07-16
04059453133809Hermann Medizintechnik GmbHH152-272222026-07-16
04059453072832Hermann Medizintechnik GmbHH112-447212026-07-13
04059453162618Hermann Medizintechnik GmbHH-585.2026-07-13
04059453161574Hermann Medizintechnik GmbHH-5062026-06-03
04059453162762Hermann Medizintechnik GmbHH-594HM2026-05-29
04059453163318Hermann Medizintechnik GmbHH65-05402026-05-29
04059453140418Hermann Medizintechnik GmbHH168-430002026-05-21
04059453078087Hermann Medizintechnik GmbHH118-280082026-05-12
04059453078810Hermann Medizintechnik GmbHH118-348222026-05-12
04059453122254Hermann Medizintechnik GmbHH144-280082026-05-12
04059453062581Hermann Medizintechnik GmbHH108-218182026-04-27

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776433031MillenniumAvalign Technologies, Inc.GCJ2026-10-01
00190776433079MillenniumAvalign Technologies, Inc.GCJ2026-10-01
00190776432911MillenniumAvalign Technologies, Inc.GCJ2026-09-30
00190776432928MillenniumAvalign Technologies, Inc.GCJ2026-09-30
B382SD13768330Surgical DirectSurgical Direct, Inc.GCJ2026-09-30
B382SD9156321100Surgical DirectSurgical Direct, Inc.GCJ2026-09-30
B382SD49195170Surgical DirectSurgical Direct, Inc.GCJ2026-09-29
B382SD9039841050Surgical DirectSurgical Direct, Inc.GCJ2026-09-29
00724995268312Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268329Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268336Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268343Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268350Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268374Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268381Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268398Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268404Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268411Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268428Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268435Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268442Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268459Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268466Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268473Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268480Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268497Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995268503Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269517Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269531Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25
00724995269548Snowden-PencerSTERIS Deutschland GmbHGCJ2026-09-25