FUJIFILM
- Primary DI
- 04547410079197
- Brand
- FUJIFILM
- Company
- FUJIFILM CORPORATION
- Model
- CA-500B
- Device description
- This product is intended to inject the reprocessing fluids during manual cleaning and manual disinfection of a FUJIFILM endoscope.
- Published
- 2016-10-18
- Public version status
- Update
- Distribution status
- In Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
- Rx
- false
- OTC
- false
- Sterile
- false
- Single use
- false
Related Records
Contact Domains
Product Codes
Product Code Classifications
Identifiers And Packaging
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| 04547410331387 | Package | GS1 | 1 | In Commercial Distribution |
| 04547410079197 | Primary | GS1 | 0 |
Alternate GTIN / UPC / EAN Codes
| Source identifier | GTIN-14 normalized | EAN-13 |
|---|---|---|
| 04547410331387 | 04547410331387 | 4547410331387 |
| 04547410079197 | 04547410079197 | 4547410079197 |
GMDN Terms
| Term | Definition |
|---|---|
| Flexible video bronchoscope, reusable | An endoscope with a flexible inserted portion for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It is inserted through the mouth or nose during bronchoscopy. Anatomical images are transmitted to the user by a video system with a charge-coupled device (CCD) chip at the distal end and the images showing on a monitor. It is commonly used to diagnose lung infections, pneumonia, or lung cancer, and allows physicians to view the insides of the lungs and take biopsies and samples of secretions. This is a reusable device. |
Storage And Handling
| Type | Low | High | Condition |
|---|---|---|---|
| Handling Environment Atmospheric Pressure | 70 KiloPascal | 106 KiloPascal | |
| Handling Environment Humidity | 30 Percent (%) Relative Humidity | 85 Percent (%) Relative Humidity | |
| Handling Environment Temperature | 10 Degrees Celsius | 40 Degrees Celsius | |
| Special Storage Condition, Specify | 0 | 0 | There must be no condensation. |
| Storage Environment Atmospheric Pressure | 70 KiloPascal | 106 KiloPascal | |
| Storage Environment Humidity | 10 Percent (%) Relative Humidity | 85 Percent (%) Relative Humidity | |
| Storage Environment Humidity | 30 Percent (%) Relative Humidity | 85 Percent (%) Relative Humidity | |
| Storage Environment Temperature | -20 Degrees Celsius | 60 Degrees Celsius | |
| Storage Environment Temperature | 10 Degrees Celsius | 40 Degrees Celsius |
Sterilization Methods
| Method |
|---|
| Ethylene Oxide;High-level Disinfectant |
Contacts
| Phone | |
|---|---|
| +018002728465 | xxx@xxx.xxx |
Regulatory Flags
- DUNS number
- 713565195
- Device count
- 1
- DM exempt
- false
- Premarket exempt
- false
- HCT/P
- false
- Kit
- false
- Combination product
- false
- Lot or batch
- true
- Serial number
- false
- Manufacturing date on label
- false
- Expiration date on label
- false
- Donation ID number
- false
- Contains natural rubber latex
- false
- No natural rubber latex
- false
- Sterilization required before use
- true
Other Devices From This Company
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 04547410571134 | FDR AQRO | DR-XD 1000 MBL ES US E | 2026-03-20 | |
| 14547410566250 | FUJIFILM | DH-084STR | 2026-02-27 | |
| 14547410566298 | FUJIFILM | DH-094STR | 2026-02-27 | |
| 14547410566335 | FUJIFILM | DH-104STR | 2026-02-27 | |
| 14547410566373 | FUJIFILM | DH-114STR | 2026-02-27 | |
| 14547410566410 | FUJIFILM | DH-124STR | 2026-02-27 | |
| 14547410566458 | FUJIFILM | DH-134STR | 2026-02-27 | |
| 14547410520580 | FUJIFILM | EB-710US | 2026-01-23 | |
| 14547410564119 | FUJIFILM | KE-007D | 2025-10-24 | |
| 04547410565195 | ECHELON Synergy | MR-TSP-156B | ECHELON Synergy Spine Coil B | 2025-11-30 |
| 04547410484786 | FDR D-EVO III G35i | DR-ID 1831 SE MDR E | 2025-08-29 | |
| 04547410484793 | FDR D-EVO III G43i | DR-ID 1832 SE MDR E | 2025-08-29 | |
| 04547410484809 | FDR D-EVO III C35i | DR-ID 1811 SE MDR E | 2025-08-29 | |
| 04547410484816 | FDR D-EVO III C43i | DR-ID 1812 SE MDR E | 2025-08-29 | |
| 04547410484823 | FDR D-EVO III C25i | DR-ID 1814 SE MDR E | 2025-08-29 | |
| 04547410511673 | FDR D-EVO III G80i | DR-ID 1836 SE MDR E | 2025-08-29 | |
| 04547410515176 | DR-ID 1200MC | DR-ID 1200 MC SOFT KIT MDR E | 2025-08-29 | |
| 14547410477242 | FUJIFILM | EC-860S/L | 2025-06-30 | |
| 14547410477273 | FUJIFILM | EC-860P/M | 2025-06-30 | |
| 14547410477303 | FUJIFILM | EC-860P/L | 2025-06-30 |
Other Devices Sharing Product Codes
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 00810116024049 | Dornier MedTech | DORNIER MEDTECH AMERICA, INC. | EOQ | 2026-03-24 |
| 00190776418021 | Millennium | Avalign Technologies, Inc. | FCL | 2026-03-23 |
| 06970671381569 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2026-03-23 |
| G3731433010 | Zinnanti Surgical | Zinnanti Surgical Design Group Inc | FCL | 2026-03-04 |
| 06937048207884 | UE Display | Zhejiang UE Medical Corp | EOQ | 2026-02-26 |
| 16937048207898 | UE BRONCHO Single-Use Bronchoscopes | Zhejiang UE Medical Corp | EOQ | 2026-02-26 |
| 16937048207904 | UE BRONCHO Single-Use Bronchoscopes | Zhejiang UE Medical Corp | EOQ | 2026-02-26 |
| 16937048207911 | UE BRONCHO Single-Use Bronchoscopes | Zhejiang UE Medical Corp | EOQ | 2026-02-26 |
| 00190776415617 | Millennium | Avalign Technologies, Inc. | FCL | 2026-01-28 |
| 14547410520580 | FUJIFILM | FUJIFILM CORPORATION | EOQ | 2026-01-23 |
| 18051887049841 | THD BIOPSY | THD SPA | FCL | 2026-01-07 |
| 18051887049865 | THD BIOPSY | THD SPA | FCL | 2026-01-07 |
| 18051887049889 | THD BIOPSY | THD SPA | FCL | 2026-01-07 |
| 06970671381026 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381040 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381187 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381200 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381248 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381323 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381347 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381477 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381491 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970671381545 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 06970800684059 | Alton | Alton (Shanghai) Medical Instruments Co., Ltd. | FCL | 2025-12-29 |
| 00860009430204 | Recon Steerable Sheath | SERPEX MEDICAL INC. | EOQ | 2025-12-08 |
| 06975202770287 | Endoso | Hunan Endoso Life Technology Co., Ltd | EOQ | 2025-11-28 |
| 06975202770294 | Endoso | Hunan Endoso Life Technology Co., Ltd | EOQ | 2025-11-28 |
| 06975202770300 | Endoso | Hunan Endoso Life Technology Co., Ltd | EOQ | 2025-11-28 |
| 06975202770317 | Endoso | Hunan Endoso Life Technology Co., Ltd | EOQ | 2025-11-28 |
| 06975202770478 | Endoso | Hunan Endoso Life Technology Co., Ltd | EOQ | 2025-11-28 |