Home GUDID 04547410104349 FUJIFILM
Primary DI 04547410104349
Brand FUJIFILM
Company FUJIFILM CORPORATION
Model CA-500BU
Device description This product is the cleaning adapter used in combination with our endoscopes in medical facilities.Do not use this product for any other purpose.
Published 2016-10-18
Public version status Update
Distribution status In Commercial Distribution
MRI safety Labeling does not contain MRI Safety Information
Rx true
Product Codes# Code, Name table Code Name EOQ BRONCHOSCOPE (FLEXIBLE OR RIGID) FCL Forceps, Biopsy, Non-Electric
Product Code Classifications# Code, Device, Specialty table Code Device Specialty Class EOQ Bronchoscope (Flexible Or Rigid) Ear, Nose, Throat 2 FCL Forceps, Biopsy, Non-Electric Gastroenterology, Urology 1
Identifiers And Packaging# Identifier, Type, Agency table Identifier Type Agency Package quantity Status 14547410104346 Package GS1 1 In Commercial Distribution 04547410104349 Primary GS1 0
Alternate GTIN / UPC / EAN Codes Source identifier, GTIN-14 normalized, EAN-13 table Source identifier GTIN-14 normalized EAN-13 14547410104346 14547410104346 04547410104349 04547410104349 4547410104349
GMDN Terms# Term, Definition table Term Definition Flexible ultrasound bronchoscope An endoscope with a flexible inserted portion intended for the visual examination and treatment of the trachea, bronchi, and lungs. It is inserted through the mouth or nose during bronchoscopy. Anatomical images are transmitted to the user by the device typically through a fibreoptic bundle or a video system, and an ultrasound probe. The probe may be built-in or inserted through a dedicated lumen so that its distal tip is positioned adjacent to that of the endoscope. It is commonly used to diagnose lung infections, pneumonia, or lung cancer, and allows physicians to view the insides of the lungs and take biopsies and samples of secretions. This is a reusable device.
Storage And Handling# Type, Low, High table Type Low High Condition Handling Environment Atmospheric Pressure 70 KiloPascal 106 KiloPascal Handling Environment Humidity 30 Percent (%) Relative Humidity 85 Percent (%) Relative Humidity Handling Environment Temperature 10 Degrees Celsius 40 Degrees Celsius Special Storage Condition, Specify 0 0 There must be no condensation. Storage Environment Atmospheric Pressure 70 KiloPascal 106 KiloPascal Storage Environment Humidity 10 Percent (%) Relative Humidity 85 Percent (%) Relative Humidity Storage Environment Humidity 30 Percent (%) Relative Humidity 85 Percent (%) Relative Humidity Storage Environment Temperature -20 Degrees Celsius 60 Degrees Celsius Storage Environment Temperature 10 Degrees Celsius 40 Degrees Celsius
Sterilization Methods# Method table Method "[""High-level Disinfectant"", ""Ethylene Oxide"", ""Moist Heat or Steam Sterilization""]" High-level Disinfectant;Ethylene Oxide;Moist Heat or Steam Sterilization
Regulatory Flags# DUNS number 713565195 Device count 1 Premarket exempt true Lot or batch true Manufacturing date on label true Sterilization required before use true Other Devices From This Company# Primary DI, Brand, Model table Primary DI Brand Model Catalog Published 04573596212318 S3ESCLS S3ESCLS 2024-01-25 04573596212325 S3ESEL S3ESEL 2021-07-18 04573596201367 OASIS MR-NVC-120 OASIS RAPID NV Coil MR-NVC-120 2026-05-29 04573596201398 OASIS MR-QFC-120 OASIS QD Flexible Body Coil(L) MR-QFC-120 2026-05-29 04573596201404 OASIS MR-QFC-120XL OASIS QD Flexible Body Coil(XL) MR-QFC-120XL 2026-05-29 04573596201411 OASIS MR-RFC-120 OASIS RAPID Foot Coil MR-RFC-120 2026-05-29 04573596201435 OASIS MR-CTL-120 OASIS CTL Coil MR-CTL-120 2026-05-29 04573596202159 OASIS MR-IBC-120 OASIS RAPID Breast Coil MR-IBC-120 2026-05-29 04547410480269 FUJIFILM VS-1000 2026-05-22 04547410529128 FUJIFILM EG-S100XT 2026-05-22 04573596200865 APERTO Lucent MR-JCR-82 Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22 04573596200889 APERTO Lucent MR-JC-81 Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et 2026-05-22 04573596200896 APERTO Lucent MR-JCR-83 Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22 04573596200902 APERTO Lucent MR-CSC-81 C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et 2026-05-22 04573596200940 APERTO Lucent MR-QWC-81 Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter 2026-05-22 04573596200964 APERTO Lucent MR-MSC-81 Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E 2026-05-22 04573596200971 APERTO Lucent MR-QRC-81 Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E 2026-05-22 04573596201480 APERTO Lucent MR-QHC-81R QD Head coil R MR-QHC-81R for APERTO Lucent 2026-05-22 04573596201497 APERTO Lucent MR-QKC-83R QD Knee coil R MR-QKC-83R for APERTO Lucent 2026-05-22 04573596201503 APERTO Lucent MR-IBC-83 Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
Other Devices Sharing Product Codes# Primary DI, Brand, Company table Primary DI Brand Company Product code Published B382SD13024290 Surgical Direct Surgical Direct, Inc. FCL 2026-07-14 06959664900000 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664900215 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664900222 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664910788 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664910801 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664910832 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664910863 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664911365 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664911372 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664911389 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664911396 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944035 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944042 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944059 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944066 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944073 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944080 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944097 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944103 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944110 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944127 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944134 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944141 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944165 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06959664944172 NA Hangzhou AGS MedTech Co., Ltd. FCL 2026-07-03 06975339628512 Single-Use Biopsy Forceps MacroLux Medical Technology Co., Ltd. FCL 2026-07-03 06975339628529 Single-Use Biopsy Forceps MacroLux Medical Technology Co., Ltd. FCL 2026-07-03 06975339628536 Single-Use Biopsy Forceps MacroLux Medical Technology Co., Ltd. FCL 2026-07-03 06975339628550 Single-Use Grasping Forceps MacroLux Medical Technology Co., Ltd. FCL 2026-07-03