Home GUDID 04547410111392 FUJIFILM
Primary DI 04547410111392
Brand FUJIFILM
Company FUJIFILM CORPORATION
Model FOV-BU1
Device description This product is used for keeping the air tightness of the forceps channel valve of the endoscope.Do not use this product for any other purpose.
Published 2016-10-18
Public version status Update
Distribution status In Commercial Distribution
MRI safety Labeling does not contain MRI Safety Information
Rx true
Single use true
Product Codes# Code, Name table Code Name EOQ BRONCHOSCOPE (FLEXIBLE OR RIGID) ITX Transducer, Ultrasonic, Diagnostic
Product Code Classifications# Code, Device, Specialty table Code Device Specialty Class EOQ Bronchoscope (Flexible Or Rigid) Ear, Nose, Throat 2 ITX Transducer, Ultrasonic, Diagnostic Radiology 2
Identifiers And Packaging# Identifier, Type, Agency table Identifier Type Agency Package quantity Status 24547410111396 Package GS1 1 In Commercial Distribution 04547410111392 Primary GS1 0 84547410111398 Unit of Use GS1 0
Alternate GTIN / UPC / EAN Codes Source identifier, GTIN-14 normalized, EAN-13 table Source identifier GTIN-14 normalized EAN-13 24547410111396 24547410111396 04547410111392 04547410111392 4547410111392 84547410111398 84547410111398
GMDN Terms# Term, Definition table Term Definition Flexible ultrasound bronchoscope An endoscope with a flexible inserted portion intended for the visual examination and treatment of the trachea, bronchi, and lungs. It is inserted through the mouth or nose during bronchoscopy. Anatomical images are transmitted to the user by the device typically through a fibreoptic bundle or a video system, and an ultrasound probe. The probe may be built-in or inserted through a dedicated lumen so that its distal tip is positioned adjacent to that of the endoscope. It is commonly used to diagnose lung infections, pneumonia, or lung cancer, and allows physicians to view the insides of the lungs and take biopsies and samples of secretions. This is a reusable device.
Storage And Handling# Type, Low, High table Type Low High Condition Handling Environment Atmospheric Pressure 70 KiloPascal 106 KiloPascal Handling Environment Humidity 30 Percent (%) Relative Humidity 85 Percent (%) Relative Humidity Handling Environment Temperature 10 Degrees Celsius 40 Degrees Celsius Special Storage Condition, Specify 0 0 There must be no condensation. Storage Environment Atmospheric Pressure 70 KiloPascal 106 KiloPascal Storage Environment Humidity 10 Percent (%) Relative Humidity 85 Percent (%) Relative Humidity Storage Environment Humidity 30 Percent (%) Relative Humidity 85 Percent (%) Relative Humidity Storage Environment Temperature -20 Degrees Celsius 60 Degrees Celsius Storage Environment Temperature 10 Degrees Celsius 40 Degrees Celsius
Sterilization Methods# Method table Method "[""High-level Disinfectant"", ""Moist Heat or Steam Sterilization"", ""Ethylene Oxide""]" High-level Disinfectant;Moist Heat or Steam Sterilization High-level Disinfectant;Moist Heat or Steam Sterilization;Ethylene Oxide
Regulatory Flags# DUNS number 713565195 Device count 10 Lot or batch true Manufacturing date on label true Sterilization required before use true Other Devices From This Company# Primary DI, Brand, Model table Primary DI Brand Model Catalog Published 04573596212318 S3ESCLS S3ESCLS 2024-01-25 04573596212325 S3ESEL S3ESEL 2021-07-18 04573596201367 OASIS MR-NVC-120 OASIS RAPID NV Coil MR-NVC-120 2026-05-29 04573596201398 OASIS MR-QFC-120 OASIS QD Flexible Body Coil(L) MR-QFC-120 2026-05-29 04573596201404 OASIS MR-QFC-120XL OASIS QD Flexible Body Coil(XL) MR-QFC-120XL 2026-05-29 04573596201411 OASIS MR-RFC-120 OASIS RAPID Foot Coil MR-RFC-120 2026-05-29 04573596201435 OASIS MR-CTL-120 OASIS CTL Coil MR-CTL-120 2026-05-29 04573596202159 OASIS MR-IBC-120 OASIS RAPID Breast Coil MR-IBC-120 2026-05-29 04547410480269 FUJIFILM VS-1000 2026-05-22 04547410529128 FUJIFILM EG-S100XT 2026-05-22 04573596200865 APERTO Lucent MR-JCR-82 Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22 04573596200889 APERTO Lucent MR-JC-81 Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et 2026-05-22 04573596200896 APERTO Lucent MR-JCR-83 Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22 04573596200902 APERTO Lucent MR-CSC-81 C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et 2026-05-22 04573596200940 APERTO Lucent MR-QWC-81 Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter 2026-05-22 04573596200964 APERTO Lucent MR-MSC-81 Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E 2026-05-22 04573596200971 APERTO Lucent MR-QRC-81 Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E 2026-05-22 04573596201480 APERTO Lucent MR-QHC-81R QD Head coil R MR-QHC-81R for APERTO Lucent 2026-05-22 04573596201497 APERTO Lucent MR-QKC-83R QD Knee coil R MR-QKC-83R for APERTO Lucent 2026-05-22 04573596201503 APERTO Lucent MR-IBC-83 Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
Other Devices Sharing Product Codes# Primary DI, Brand, Company table Primary DI Brand Company Product code Published 00841436122061 Verza Guidance System CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436125444 Cradle CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436125451 Classic Stepper CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436125833 Needle Guide Bracket CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436125857 Needle Guide Bracket CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436126045 Verza Guidance System CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436126656 Multi-Purpose Workstation ™ Stepper CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841436126663 Cradle CIVCO MEDICAL INSTRUMENTS CO., INC. ITX 2026-07-23 00841517112011 iLOOK FUJIFILM SONOSITE, INC. ITX 2026-07-16 00841517112028 iLOOK FUJIFILM SONOSITE, INC. ITX 2026-07-16 00841517112035 iLOOK FUJIFILM SONOSITE, INC. ITX 2026-07-16 00841517112462 iLOOK FUJIFILM SONOSITE, INC. ITX 2026-07-16 00841517139018 iLOOK FUJIFILM SONOSITE, INC. ITX 2026-07-16 00860013043605 EdgeLife Technologies Edge Life Technologies, LLC ITX 2026-07-10 00860013043612 EdgeLife Technologies Edge Life Technologies, LLC ITX 2026-07-10 00841517112653 rP19x/5-1 MHz Armored FUJIFILM SONOSITE, INC. ITX 2026-06-24 00841517112660 L12-3 FUJIFILM SONOSITE, INC. ITX 2026-06-24 00841517112677 L15-4 FUJIFILM SONOSITE, INC. ITX 2026-06-24 00852619008041 QT Scanner 2000 Qt Imaging, Inc. ITX 2026-06-24 00841517112646 L15-4 FUJIFILM SONOSITE, INC. ITX 2026-06-23 00841517112639 L12-3 FUJIFILM SONOSITE, INC. ITX 2026-06-22 00198953078716 LOGIQ GE Medical Systems (China) Co.,Ltd. ITX 2026-06-10 00198953078754 LOGIQ GE Medical Systems (China) Co.,Ltd. ITX 2026-06-10 00198953147009 LOGIQ GE Medical Systems (China) Co.,Ltd. ITX 2026-06-10 00198953147016 LOGIQ GE Medical Systems (China) Co.,Ltd. ITX 2026-06-10 00198953147351 LOGIQ GE Medical Systems (China) Co.,Ltd. ITX 2026-06-10 10810068810940 MONARCH™ Advanced Imaging Accessory Kit Auris Health, Inc. EOQ 2026-06-02 00850050934233 EndoSound® EVS Probe Endosound, Inc. ITX 2026-06-01 04987670105937 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. ITX 2026-06-01 04987670106194 DIAGNOSTIC ULTRASOUND SYSTEM CANON INC. ITX 2026-06-01