FUJIFILM

Primary DI
04547410324037
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
CA-510/A
Device description
This product is the cleaning adapter used in combination with our endoscopes in medical facilities.Do not use this product for any other purpose.
Published
2022-10-07
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FFYAdaptor, bulbs, miscellaneous, for endoscope

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FFYAdaptor, Bulbs, Miscellaneous, For EndoscopeGastroenterology, Urology1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
24547410324031PackageGS11In Commercial Distribution
04547410324037PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
2454741032403124547410324031
04547410324037045474103240374547410324037

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
"[""Moist Heat or Steam Sterilization"", ""High-level Disinfectant"", ""Ethylene Oxide""]"

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
Premarket exempt
true
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04547410580211RAS15-3L-ARRAS15-3L-AR2026-11-06
04547410580235RAS12-2C-ARRAS12-2C-AR2026-11-06
04547410575392Synapse 3DSYNAPSE 3D SOFT V7.2 US UDI2026-10-30
04547410582901FDR CROSS SlimDR-XD 3000 SLIM MBL E2026-08-14
04547410524642FUJIFILMEB-840T2026-07-30
04547410524680FUJIFILMEB-840S2026-07-30
04573596212318S3ESCLSS3ESCLS2024-01-25
04573596212325S3ESELS3ESEL2021-07-18
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00724995368333CLEANASCOPE AdvantageSTERIS ITALY SRLFFY2026-11-12
00724995368340CLEANASCOPE AdvantageSTERIS ITALY SRLFFY2026-11-12
00724995368357CLEANASCOPE AdvantageSTERIS ITALY SRLFFY2026-11-12
00724995368470CLEANASCOPESTERIS ITALY SRLFFY2026-11-12
00724995368487CLEANASCOPESTERIS ITALY SRLFFY2026-11-12
00724995368494CLEANASCOPESTERIS ITALY SRLFFY2026-11-12
06936603218259CO2 AdapterYangzhou Fartley Medical Instrument Technology Co., LtdFFY2026-10-25
06936603235508CO2 AdapterYangzhou Fartley Medical Instrument Technology Co., LtdFFY2026-10-25
04897129991755CeroFrictSML Med-Tech Solutions LimitedFFY2026-10-13
00724995356699CLEANASCOPESTERIS ITALY SRLFFY2026-05-26
00724995356705CLEANASCOPESTERIS ITALY SRLFFY2026-05-26
00724995356712CLEANASCOPE ADVANTAGESTERIS ITALY SRLFFY2026-05-26
00724995356729CLEANASCOPE ADVANTAGESTERIS ITALY SRLFFY2026-05-26
04897106957880andorate® 2-piece Cleaning Adapter + 3-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957897andorate® 2-piece Cleaning Adapter + 4-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957941andorate® 2-piece Cleaning Adapter + 3-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957958andorate® 2-piece Cleaning Adapter + 4-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106958016andorate® 2-piece Cleaning Adapter + 3-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106958023andorate® 2-piece Cleaning Adapter + 4-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957743andorate® Air Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-11-21
04547410564112FUJIFILMFUJIFILM CORPORATIONFFY2025-10-24
14547410564119FUJIFILMFUJIFILM CORPORATIONFFY2025-10-24
04897106957804Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957811Biopsy Port Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957828Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957798Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
14897106957801Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
14897106957818Biopsy Port Cleaning AdapterGA Health Company LimitedFFY2025-08-04
14897106957825Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957071Air Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-07-31