FUJIFILM

Primary DI
04547410330915
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
ED-530XT
Device description
The Fujifilm Duodenoscope Model ED-530XT is intended for the visualization of the duodenum and upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of the esophagus, stomach, and duodenum.
Published
2016-12-14
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
FDTduodenoscope and accessories, flexible/rigid

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FDTDuodenoscope And Accessories, Flexible/RigidGastroenterology, Urology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
14547410330912PackageGS11In Commercial Distribution
04547410330915PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
1454741033091214547410330912
04547410330915045474103309154547410330915

GMDN Terms#

Term, Definition table
TermDefinition
Flexible video duodenoscope, reusableAn endoscope with a flexible inserted portion intended for the visual examination and treatment of the duodenum (the first part of the small intestine). It is inserted into the body through the mouth during duodenoscopy. Anatomical images are transmitted to the user by a video system with a charge-coupled device (CCD) chip at the distal end of the endoscope and the images showing on a monitor. This device is commonly used to examine structures and mucous membranes of the duodenum for conditions like ulcers, polyps, and cancer. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Temperature10 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method
"[""High-level Disinfectant"", ""Ethylene Oxide""]"
High-level Disinfectant;Ethylene Oxide

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
Serial number
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04573596212318S3ESCLSS3ESCLS2024-01-25
04573596212325S3ESELS3ESEL2021-07-18
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
04953170467370SINGLE USE DISTAL COVEROLYMPUS MEDICAL SYSTEMS CORP.FDT2026-03-06
14953170467377SINGLE USE DISTAL COVEROLYMPUS MEDICAL SYSTEMS CORP.FDT2026-03-06
04961333255801INSPIRAHOYA CORPORATIONFDT2025-06-20
04961333255825INSPIRAHOYA CORPORATIONFDT2025-06-20
05707480157167Ambu® aScope™ Duodeno 2Ambu A/SFDT2025-03-29
04961333356355PENTAX MedicalHOYA CORPORATIONFDT2024-09-03
04961333356331PENTAX MedicalHOYA CORPORATIONFDT2024-09-03
05707480157143Ambu® aScope™ Duodeno 2Ambu A/SFDT2024-07-19
05707480157136Ambu® aScope™ Duodeno 2Ambu A/SFDT2024-07-19
04961333254910INSPIRAHOYA CORPORATIONFDT2023-12-01
04961333247974INSPIRAHOYA CORPORATIONFDT2023-09-16
14961333232960PENTAX MedicalHOYA CORPORATIONFDT2023-07-31
14961333232991PENTAX MedicalHOYA CORPORATIONFDT2023-07-31
14961333246233PENTAX MedicalHOYA CORPORATIONFDT2023-07-31
04961333084456PENTAXHOYA CORPORATIONFDT2023-07-31
04961333084470PENTAXHOYA CORPORATIONFDT2023-07-31
04961333232963PENTAX MedicalHOYA CORPORATIONFDT2023-07-31
04961333232994PENTAX MedicalHOYA CORPORATIONFDT2023-07-31
04961333246236PENTAX MedicalHOYA CORPORATIONFDT2023-07-31
04953170438066Air/water valveOLYMPUS MEDICAL SYSTEMS CORP.FDT2023-04-22
04953170438349CONNECTING TUBEOLYMPUS MEDICAL SYSTEMS CORP.FDT2023-04-19
04953170441271SINGLE USE DISTAL COVEROLYMPUS MEDICAL SYSTEMS CORP.FDT2022-06-01
14953170441278SINGLE USE DISTAL COVER MAJ-2315OLYMPUS MEDICAL SYSTEMS CORP.FDT2022-06-01
04953170452024EVIS EXERA III DUODENOVIDEOSCOPE OLYMPUS TJF-Q190VOLYMPUS MEDICAL SYSTEMS CORP.FDT2022-06-01
05707480157402aScope™ DuodenoAmbu A/SFDT2022-04-19
05707480157426aScope™ DuodenoAmbu A/SFDT2022-04-19
04961333246632PENTAX MedicalHOYA CORPORATIONFDT2022-02-02
04961333246168N/AHOYA CORPORATIONFDT2022-02-02
04953170063749EYEPIECE CAPOLYMPUS MEDICAL SYSTEMS CORP.FDT2021-12-20
04953170064012LIGHTGUIDE CAPOLYMPUS MEDICAL SYSTEMS CORP.FDT2021-12-20