FUJIFILM

Primary DI
04547410332360
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
SU-1 PLATINUM FV666A
Device description
The Fujifilm ultrasonic processors SU-1 PLATINUM is intended to be used in combination with Fujifilm ultrasonic endoscope, video processor, light source, monitor, recorder, and various peripheral devices. The product is intended to provide ultrasonic images of the trachea, bronchial tree and surrounding organs, or submucosal and peripheral organs of the upper gastrointestinal tract for observation, recording and to aid in diagnosis during endoscopic evaluation.
Published
2016-09-16
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FDSGastroscope and accessories, flexible/rigid
ITXTransducer, Ultrasonic, Diagnostic
IYNSystem, Imaging, Pulsed Doppler, Ultrasonic
IYOSystem, Imaging, Pulsed Echo, Ultrasonic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FDSGastroscope And Accessories, Flexible/RigidGastroenterology, Urology2
ITXTransducer, Ultrasonic, DiagnosticRadiology2
IYNSystem, Imaging, Pulsed Doppler, UltrasonicRadiology2
IYOSystem, Imaging, Pulsed Echo, UltrasonicRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K153206000
K200850000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K153206000Fujifilm Ultrasonic Processors SU-1 PLATINUM and SU-1Fujifilm Medical System U.S.A., Inc.2016-03-03FDS
K200850000Fujifilm Ultrasonic ProcessorFujifilm Corporation2020-07-06FDS

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04547410332360PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04547410332360045474103323604547410332360

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04547410580211RAS15-3L-ARRAS15-3L-AR2026-11-06
04547410580235RAS12-2C-ARRAS12-2C-AR2026-11-06
04547410575392Synapse 3DSYNAPSE 3D SOFT V7.2 US UDI2026-10-30
04547410582901FDR CROSS SlimDR-XD 3000 SLIM MBL E2026-08-14
04547410524642FUJIFILMEB-840T2026-07-30
04547410524680FUJIFILMEB-840S2026-07-30
04573596212318S3ESCLSS3ESCLS2024-01-25
04573596212325S3ESELS3ESEL2021-07-18
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00850086617001GINOVOGINOVO, CORP.FDS2026-11-10
00850086617056GINOVOGINOVO, CORP.FDS2026-11-10
00841517112783L19-5FUJIFILM SONOSITE, INC.IYO2026-11-09
00841517112783L19-5FUJIFILM SONOSITE, INC.IYN2026-11-09
00841517112783L19-5FUJIFILM SONOSITE, INC.ITX2026-11-09
00850091793004HyperVue Imaging SystemSpectrawave, Inc.IYO2026-11-09
00850091793011HyperVue Imaging SystemSpectrawave, Inc.IYO2026-11-09
00860008045546HyperVue Imaging System - IntegratedSpectrawave, Inc.IYO2026-11-09
00860008045591Starlight Imaging CatheterSpectrawave, Inc.IYO2026-11-09
09353278000816Kosmos OTS iOSECHONOUS, INC.IYN2026-11-09
04547410580211RAS15-3L-ARFUJIFILM CORPORATIONITX2026-11-06
04547410580211RAS15-3L-ARFUJIFILM CORPORATIONIYO2026-11-06
04547410580211RAS15-3L-ARFUJIFILM CORPORATIONIYN2026-11-06
04547410580235RAS12-2C-ARFUJIFILM CORPORATIONIYO2026-11-06
04547410580235RAS12-2C-ARFUJIFILM CORPORATIONITX2026-11-06
04547410580235RAS12-2C-ARFUJIFILM CORPORATIONIYN2026-11-06
04719873001101Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONIYO2026-11-04
04719873001101Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONITX2026-11-04
04719873001101Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONIYN2026-11-04
04719873001132Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONITX2026-11-04
04719873001132Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONIYO2026-11-04
04719873001132Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONIYN2026-11-04
04719873001156Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONITX2026-11-04
04719873001156Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONIYO2026-11-04
04719873001156Esaote MyLabX1 Diagnostic Ultrasound SystemQISDA CORPORATIONIYN2026-11-04
06903053063852Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.IYN2026-10-31
06903053063869Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.IYN2026-10-31
06903053063876Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.IYN2026-10-31
06903053063883Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.IYN2026-10-31
06903053063890Diagnostic Ultrasound SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.ITX2026-10-31