FUJIFILM

Primary DI
04547410337419
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
VP-7000
Device description
The VP-7000 unit is used for endoscopic observation, diagnosis, treatment, and image recording. It is intended to process electronic signals transmitted from a video endoscope (a video camera in an endoscope). This product may be used on all patients requiring endoscopic examination and when using a Fujinon/FUJIFILM medical endoscope and light source together with monitor, recorder and various peripheral devices. BLI (Blue Light Imaging), LCI (Linked Color Imaging) and FICE (Flexible spectral-Imaging Color Enhancement) are adjunctive tools for gastrointestinal endoscopic examination which can be used to supplement Fujifilm white light endoscopy. BLI, LCI and FICE are not intended to replace histopathological sampling as a means of diagnosis.
Published
2017-05-23
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FETEndoscopic video imaging system/component, gastroenterology-urology
GCJLaparoscope, General & Plastic Surgery
MUDOximeter, Tissue Saturation
NTNLed Light Source
NWBEndoscope, accessories, narrow band spectrum
PEAEndoscope, accessories, image post-processing for color enhancement

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FETEndoscopic Video Imaging System/Component, Gastroenterology-UrologyGastroenterology, Urology2
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2
MUDOximeter, Tissue SaturationCardiovascular2
NTNLed Light SourceGastroenterology, Urology2
NWBEndoscope, Accessories, Narrow Band SpectrumGastroenterology, Urology2
PEAEndoscope, Accessories, Image Post-Processing For Color EnhancementGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K203717000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K203717000Processor VP-7000, Light Source BL-7000X, Image Processing Unit EX-0Fujifilm Corporaton2021-06-30GCJ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04547410337419PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04547410337419045474103374194547410337419

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic video image processing unitA mains electricity (AC-powered) device designed to receive and process the electronic signals sent from a video endoscope or endoscopic video camera; it does not include the endoscope nor light source and is not designed to control the endoscope. It may have additional features which compensate for/enhance the colour and light qualities provided. The resulting picture images are sent to and shown on a visual display unit (VDU), typically to assist the endoscope operator with an ongoing intervention and often to allow the patient visualization of the process; the images can be recorded on a video recorder or stored on computerized media.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
04573596202210APERTO LucentMR-QFC-82NFlexible Body coil N(M) MR-QFC-82N for APERTO Luce2026-05-22
04573596202227APERTO LucentMR-QFC-83NFlexible Body coil N(L) MR-QFC-83N for APERTO Luce2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00198506091247ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-03
00198506091254ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-03
00192896123427TrocarSONTEC INSTRUMENTS, INC.GCJ2026-06-02
00192896123434Flexible Trocar SleeveSONTEC INSTRUMENTS, INC.GCJ2026-06-02
E496C35BTU200C35-Bipolar Tube L 20cm D 3,5mmAB MEDICAGCJ2026-05-28
E496C35IBDM200C35- Bipolar Maryland Insert L20cm D 3,5mmAB MEDICAGCJ2026-05-28
E496C35IBFS200C35-Bipolar Insert L 20cm D 3,5mmAB MEDICAGCJ2026-05-28
08800112400352cCeLLVPIX Medical, Inc.GCJ2026-05-14
08800112400482cCeLLVPIX Medical, Inc.GCJ2026-05-14
08800112400499cCeLLVPIX Medical, Inc.GCJ2026-05-14
08800042701833ARTISENTIAL TROCARLIVSMEDGCJ2026-04-17
G4532420530BC0PEAK MEDICALPeak Medical Distribution Inc.GCJ2026-02-24
10884521845985INVOSCovidien LPMUD2025-07-03
10192253052398DevonCardinal Health 200, LLCGCJ2025-05-29
08904332600766MediflexENDOSYS HEALTHCARE INDIA PRIVATE LIMITEDGCJ2025-05-19
10192253052442DevonCardinal Health 200, LLCGCJ2025-03-27
10080196800612MedlineMEDLINE INDUSTRIES, INC.GCJ2024-03-05
07613327616682SPYSTRYKER CORPORATIONNWB2024-02-27
07613327616699SPYSTRYKER CORPORATIONNWB2024-02-27
07613327616705SPYSTRYKER CORPORATIONNWB2024-02-27
07613327616712SPYSTRYKER CORPORATIONNWB2024-02-27
07613327616729SPYSTRYKER CORPORATIONNWB2024-02-27
07613327616743SPYSTRYKER CORPORATIONNWB2024-02-27
076133276089151788STRYKER CORPORATIONNWB2023-12-11
08033638801048Pen LEDSAPI MED SPANTN2023-08-02
07613327413281Connected OR HubSTRYKER CORPORATIONGCJ2023-07-26
07613327562545NASTRYKER CORPORATIONGCJ2021-12-23
07613327562552NASTRYKER CORPORATIONGCJ2021-12-23
08051414960468Cyber BladeSIDAM SRLGCJ2021-02-04
07613327502800PinpointSTRYKER CORPORATIONGCJ2019-07-30