FUJIFILM

Primary DI
04547410349078
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
EG-580UR
Device description
FUJIFILM Endoscope Model EG-580UR is intended for the visualization of the upper digestive tract, specifically for the observation, diagnosis, and endoscopic treatment of submucosal and peripheral organs of the esophagus, stomach, and duodenum.
Published
2019-09-30
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FDSGastroscope And Accessories, Flexible/Rigid
ITXTransducer, Ultrasonic, Diagnostic
ODGEndoscopic Ultrasound System, Gastroenterology-Urology

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FDSGastroscope And Accessories, Flexible/RigidGastroenterology, Urology2
ITXTransducer, Ultrasonic, DiagnosticRadiology2
ODGEndoscopic Ultrasound System, Gastroenterology-UrologyGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K221952000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K221952000Endoscope Model EG-580UT and Endoscope Model EG-580URFujifilm Corporation2022-08-04ODG

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
14547410349075PackageGS11In Commercial Distribution
04547410349078PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
1454741034907514547410349075
04547410349078045474103490784547410349078

GMDN Terms#

Term, Definition table
TermDefinition
Flexible ultrasound gastroduodenoscopeAn endoscope with a flexible inserted portion, combined with an ultrasound probe, intended for the visual examination and treatment of the upper gastrointestinal (GI) tract [oesophagus, stomach, and duodenum (the first part of the small intestine), including the pancreas and the bile duct]. It is inserted into the body through the mouth during gastroduodenoscopy. Anatomical images are transmitted to the user through a fibreoptic bundle or a video system and the ultrasound probe. The probe may be built-in, or inserted through a dedicated lumen. This device is commonly used to examine structures of the stomach, duodenum, pancreas, and bile duct. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
"[""Ethylene Oxide"", ""High-level Disinfectant""]"

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
Serial number
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
04573596202210APERTO LucentMR-QFC-82NFlexible Body coil N(M) MR-QFC-82N for APERTO Luce2026-05-22
04573596202227APERTO LucentMR-QFC-83NFlexible Body coil N(L) MR-QFC-83N for APERTO Luce2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00850050934233EndoSound® EVS ProbeEndosound, Inc.ITX2026-06-01
00850050934240EndoSound® EVS SideBeam 5103Endosound, Inc.ODG2026-06-01
00850050934257EndoSound® Coax Transducer Extension Connector (TEC)Endosound, Inc.ODG2026-06-01
00850050934264EndoSound® EVS SideBeam 5105 (4 pouches)Endosound, Inc.ODG2026-06-01
04987670105937DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
04987670106194DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.ITX2026-06-01
08800013510112L8-17HAlpinion Medical Systems Co., Ltd.ITX2026-05-29
00198953121382VolusonGE Ultrasound Korea Ltd.ITX2026-05-28
08800289975974R30 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2026-01-20
08056304455826MyLabC25ESAOTE SPAITX2025-12-10
08056304455833MyLabC30ESAOTE SPAITX2025-12-10
08056304455017MyLabA50ESAOTE SPAITX2025-07-07
08056304455215MyLabE85ESAOTE SPAITX2025-07-07
08056304455307MyLabA70ESAOTE SPAITX2025-07-07
08056304455437MyLabA50ESAOTE SPAITX2025-07-07
08056304455451MyLabA70ESAOTE SPAITX2025-07-07
08056304455635MyLabE80ESAOTE SPAITX2025-07-07
08056304455642MyLabE85ESAOTE SPAITX2025-07-07
08800289970351cV8 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.ITX2025-02-27
00850055427075HYDROS TRUS ProbePROCEPT BioRobotics CorporationITX2024-09-06
08056304455628MyLabE80ESAOTE SPAITX2024-03-29
08056304454980MyLabX90ESAOTE SPAITX2023-12-14
08056304454676MyLabX9ESAOTE SPAITX2023-06-13
08800013544001X-CUBE 50Alpinion Medical Systems Co., Ltd.ITX2022-11-01
08800013545008X-CUBE 60Alpinion Medical Systems Co., Ltd.ITX2022-11-01
08800013511171C1-6CAlpinion Medical Systems Co., Ltd.ITX2022-07-15
08800013511164C1-7GTAlpinion Medical Systems Co., Ltd.ITX2022-02-05
08714729982852MDU5 PLUSBOSTON SCIENTIFIC CORPORATIONITX2021-11-29
08714729982869MDU5 PLUSBOSTON SCIENTIFIC CORPORATIONITX2021-11-29
08714729982876MDU5 PLUSBOSTON SCIENTIFIC CORPORATIONITX2021-11-29