FUJIFILM

Primary DI
04547410520583
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
EB-710US
Device description
This product is an ultrasonic endoscope intended for the observation, diagnosis and endoscopic treatment of the esophagus, trachea, bronchus and lesions adjacent to these structures using ultrasonic images, at medical facilities under the management of physicians.This product is not intended for use on children and infants.
Published
2026-01-23
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
EOQBronchoscope (Flexible Or Rigid)
ITXTransducer, Ultrasonic, Diagnostic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
EOQBronchoscope (Flexible Or Rigid)Ear, Nose, Throat2
ITXTransducer, Ultrasonic, DiagnosticRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K250863000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K250863000FUJIFILM Ultrasonic Endoscope EB-710USFujifilm Corporation2025-12-12EOQ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
14547410520580PackageGS11In Commercial Distribution
04547410520583PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
1454741052058014547410520580
04547410520583045474105205834547410520583

GMDN Terms#

Term, Definition table
TermDefinition
Flexible ultrasound bronchoscopeAn endoscope with a flexible inserted portion intended for the visual examination and treatment of the trachea, bronchi, and lungs. It is inserted through the mouth or nose during bronchoscopy. Anatomical images are transmitted to the user by the device typically through a fibreoptic bundle or a video system, and an ultrasound probe. The probe may be built-in or inserted through a dedicated lumen so that its distal tip is positioned adjacent to that of the endoscope. It is commonly used to diagnose lung infections, pneumonia, or lung cancer, and allows physicians to view the insides of the lungs and take biopsies and samples of secretions. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00no dew condensation
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method
"[""High-level Disinfectant"", ""Ethylene Oxide"", ""Hydrogen Peroxide""]"

Regulatory Flags#

DUNS number
713565195
Device count
1
Serial number
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04547410524642FUJIFILMEB-840T2026-07-30
04547410524680FUJIFILMEB-840S2026-07-30
04573596212318S3ESCLSS3ESCLS2024-01-25
04573596212325S3ESELS3ESEL2021-07-18
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
04547410524642FUJIFILMFUJIFILM CORPORATIONEOQ2026-07-30
04547410524680FUJIFILMFUJIFILM CORPORATIONEOQ2026-07-30
06972084140634WiScope®Ningbo Wise Optomech Technology CorporationEOQ2026-07-28
06972084140641WiScope®Ningbo Wise Optomech Technology CorporationEOQ2026-07-28
06972084140658WiScope®Ningbo Wise Optomech Technology CorporationEOQ2026-07-28
00841436122078Biopsy BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436122900Biopsy BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436124294Biopsy BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436125895Needle Guide Starter KitCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436126052Biopsy BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436126403Needle Guide Starter KitCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436126410Needle Guide BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436127028Verza Guidance SystemCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00841436127035Biopsy BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
10841436125311CIV-Clear™ Transducer CoverCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
10841436125915Needle GuideCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
10841436125939Needle GuideCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
10841436125953Needle GuideCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
10841436127056Cable SleeveCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
10841436127186Needle GuideCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-27
00195278713322RIC12-DGE Healthcare Austria GmbH & Co OGITX2026-07-24
04987670106088CONVEX ARRAY TRANSDUCERCANON INC.ITX2026-07-24
00841436122061Verza Guidance SystemCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436125444CradleCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436125451Classic StepperCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436125833Needle Guide BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436125857Needle Guide BracketCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436126045Verza Guidance SystemCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436126656Multi-Purpose Workstation ™ StepperCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23
00841436126663CradleCIVCO MEDICAL INSTRUMENTS CO., INC.ITX2026-07-23