FUJIFILM

Primary DI
04547410520910
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
CT-2LT
Device description
This product is intended to check whether the FUJIFILM Leak Tester LT-100 can properly test the airtightness of a FUJIFILM endoscope. Do not use this product for any other purposes.
Published
2023-12-15
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
FCYBulb, Inflation, For Endoscope

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FCYBulb, Inflation, For EndoscopeGastroenterology, Urology1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
14547410520917PackageGS11In Commercial Distribution
04547410520910PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
1454741052091714547410520917
04547410520910045474105209104547410520910

GMDN Terms#

Term, Definition table
TermDefinition
Endoscope leak tester tubingA length of flexible tube with connectors intended to deliver a medium (typically air) from a leak tester to the interior of an endoscope during a leak test; it may in addition be intended for other endoscope pre- or post-procedural processing (e.g., allow connection of a fluid seal). This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius

Regulatory Flags#

DUNS number
713565195
Device count
1
Premarket exempt
true
Lot or batch
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04573596201367OASISMR-NVC-120OASIS RAPID NV Coil MR-NVC-1202026-05-29
04573596201398OASISMR-QFC-120OASIS QD Flexible Body Coil(L) MR-QFC-1202026-05-29
04573596201404OASISMR-QFC-120XLOASIS QD Flexible Body Coil(XL) MR-QFC-120XL2026-05-29
04573596201411OASISMR-RFC-120OASIS RAPID Foot Coil MR-RFC-1202026-05-29
04573596201435OASISMR-CTL-120OASIS CTL Coil MR-CTL-1202026-05-29
04573596202159OASISMR-IBC-120OASIS RAPID Breast Coil MR-IBC-1202026-05-29
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
04573596202210APERTO LucentMR-QFC-82NFlexible Body coil N(M) MR-QFC-82N for APERTO Luce2026-05-22
04573596202227APERTO LucentMR-QFC-83NFlexible Body coil N(L) MR-QFC-83N for APERTO Luce2026-05-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00724995360191NAMEDIVATORS INC.FCY2026-02-04
00724995360207NAMEDIVATORS INC.FCY2026-02-04
00724995360214NAMEDIVATORS INC.FCY2026-02-04
00724995360221NAMEDIVATORS INC.FCY2026-02-04
00724995360238NAMEDIVATORS INC.FCY2026-02-04
00724995360245NAMEDIVATORS INC.FCY2026-02-04
00816185001127Dovideq LeakControl DeviceTorvan Medical IncFCY2025-09-18
00724995244415NAMEDIVATORS INC.FCY2025-06-10
00724995244422NAMEDIVATORS INC.FCY2025-06-10
00724995244439NAMEDIVATORS INC.FCY2025-06-10
00724995244446NAMEDIVATORS INC.FCY2025-06-10
00724995244453NAMEDIVATORS INC.FCY2025-06-10
00724995244460NAMEDIVATORS INC.FCY2025-06-10
00724995244477NAMEDIVATORS INC.FCY2025-06-10
00724995244484NAMEDIVATORS INC.FCY2025-06-10
00724995244491NAMEDIVATORS INC.FCY2025-06-10
50724995244410NAMEDIVATORS INC.FCY2025-06-10
50724995244427NAMEDIVATORS INC.FCY2025-06-10
50724995244434NAMEDIVATORS INC.FCY2025-06-10
50724995244441NAMEDIVATORS INC.FCY2025-06-10
50724995244458NAMEDIVATORS INC.FCY2025-06-10
50724995244465NAMEDIVATORS INC.FCY2025-06-10
50724995244472NAMEDIVATORS INC.FCY2025-06-10
50724995244489NAMEDIVATORS INC.FCY2025-06-10
50724995244496NAMEDIVATORS INC.FCY2025-06-10
00816185001141AutoSink with Endoscope Leak TesterTorvan Medical IncFCY2025-04-28
00816185001158LT Connector 1OTorvan Medical IncFCY2025-04-28
06971919462156noneNingbo Albert Novosino Co.,Ltd.FCY2025-03-14
04048551054901n.a.Karl Storz GmbH & Co. KGFCY2024-11-29
04055207070055NARichard Wolf GmbHFCY2024-06-03