KOWA KT-800

Primary DI
04987646804109
Brand
KOWA KT-800
Company
KOWA COMPANY,LTD.
Model
TO8K
Device description
The Kowa KT-800 is indicated for measuring intraocular pressure without contacting the eye to aid in the screening and diagnosis of glaucoma.
Published
2016-09-16
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
HKXTonometer, Ac-Powered

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HKXTonometer, Ac-PoweredOphthalmic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K053444000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K053444000KOWA KT-800Kowa Co. , Ltd.2006-06-09HKX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04987646804109PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04987646804109049876468041094987646804109

GMDN Terms#

Term, Definition table
TermDefinition
Ophthalmic tonometer, battery-operatedAn ophthalmic, battery-powered, measuring instrument designed for determining the intraocular pressure (IOP) by exerting an external force against the eye which provides a reading of the resistance of the tunica of the eye to deformation (the extent of corneal indentation) which is expressed in millimetre(s) of mercury (mmHg). This hand-held device (known as a contact type, e.g., a Perkins tonometer) is often used for, e.g., the examination of postoperative, bedridden and paediatric patients.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Depth457Millimeter
Height458Millimeter
Weight18Kilogram
Width274Millimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Storage Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-15 Degrees Celsius60 Degrees Celsius

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
692281073
Device count
1
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04987646807575KOWA nonmyd 8K9L61K2016-09-16
04987646810476KOWA SL-19SL192BK/W2024-10-08
04987646810223KOWA SL-19SL191BK/W2023-01-10
04987646810032KOWA SL-19SL191K/W2022-12-07
04987646810049KOWA SL-19SL191K/A2022-12-07
04987646810056KOWA SL-19SL191K/G2022-12-07
04987646810063KOWA SL-19SL191K/P2022-12-07
04987646810070KOWA SL-19SL191K/B2022-12-07
04987646804031KOWA SL-15SL150K2016-09-16
04987646806905KOWA SL-17SL170K/W2016-09-16
04987646806912KOWA SL-17SL170K/A2016-09-16
04987646806929KOWA SL-17SL170K/G2016-09-16
04987646806936KOWA SL-17SL170K/P2016-09-16
04987646809128KOWA nonmyd AFK9L64K2020-01-15
04987646807728KOWA DR-1αDE2K2019-06-10
04987646808923KOWA VK-2sVK28K2019-06-10
04987646808930KOWA VK-2sVK28UE2019-06-10
04987646808947KOWA VK-2sVK28U2E2019-06-10
04987646805113KOWA AP-7000FT10K2019-01-08
04987646800583KOWA GENESIS-DfK9L51BK2016-09-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
04719872711230MiiSMEDIMAGING INTEGRATED SOLUTION INC.HKX2026-04-29
04719876420046TonoVueCRYSTALVUE MEDICAL CORPORATIONHKX2026-04-15
06430033851920iCare ST500ICARE FINLAND OYHKX2025-12-05
04571130283343AUTO KERATO-REFRACTO TONOMETER TRK-3 OMNIATOPCON CORPORATIONHKX2025-11-17
07350023774307CalcibonBiomet Biologics, LLCHKX2025-10-09
03664188000589ZEISSLUNEAU TECHNOLOGY OPERATIONSHKX2025-03-11
03664188000558ESSILORLUNEAU TECHNOLOGY OPERATIONSHKX2025-01-02
03664188000565ESSILORLUNEAU TECHNOLOGY OPERATIONSHKX2025-01-02
06430033851784ST500 SmartCradleICARE FINLAND OYHKX2024-11-07
06430033851791ST500 AdapterICARE FINLAND OYHKX2024-11-07
06430033851807ST500 RemoteICARE FINLAND OYHKX2024-11-07
06430033851883iCare ST500ICARE FINLAND OYHKX2024-11-07
00851158007683Eli EzerU.S. OPHTHALMIC, L.L.C.HKX2024-01-25
04547451026686INAMI INAMI & CO., LTD.HKX2023-07-27
04547451026709INAMIINAMI & CO., LTD.HKX2023-07-27
03615020000458WAVE ANALYZER MEDICA 800ESSILOR INTERNATIONALHKX2023-07-25
08800019600411Applanation Tonometer HT-5000Huvitz Co., Ltd.HKX2023-06-12
08800019600435Non-contact Tonometer HNT-1PHuvitz Co., Ltd.HKX2023-06-12
08800019600558Auto Tono/Refracto/Kerato/Pachymeter HTR-1AHuvitz Co., Ltd.HKX2023-06-12
03664188000145Visionix VX650LUNEAU TECHNOLOGY OPERATIONSHKX2023-06-08
03664188000404RODENSTOCKLUNEAU TECHNOLOGY OPERATIONSHKX2023-06-08
03664188000923RODENSTOCKLUNEAU TECHNOLOGY OPERATIONSHKX2023-06-08
03664188000930RODENSTOCKLUNEAU TECHNOLOGY OPERATIONSHKX2023-06-08
04047844051269DIPLOMAT Def.SIGNUS Medizintechnik GmbHHKX2022-06-20
04047844051276DIPLOMAT Def.SIGNUS Medizintechnik GmbHHKX2022-06-20
04582273600263NON-CONTACT TONOMETERTOMEY CORPORATION.HKX2022-04-01
00851158007706Eli EzerU.S. OPHTHALMIC, L.L.C.HKX2021-01-04
M6333974340JEDMEDJEDMED INSTRUMENT COMPANYHKX2020-09-01
03664188000039VISIONIXLUNEAU TECHNOLOGY OPERATIONSHKX2020-05-25
03664188000046VISIONIXLUNEAU TECHNOLOGY OPERATIONSHKX2020-05-25