KOWA VX-10a

Primary DI
04987646804147
Brand
KOWA VX-10a
Company
KOWA COMPANY,LTD.
Model
K9L48BK
Device description
KOWA VX-10a is intended for taking pictures of fundus images with mydriatic or without mydriatic.
Published
2016-09-16
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
HKICamera, Ophthalmic, Ac-Powered

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HKICamera, Ophthalmic, Ac-PoweredOphthalmic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K091683000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K091683000KOWA VX-10 AKowa Co. , Ltd.2009-07-02HKI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04987646804147PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04987646804147049876468041474987646804147

GMDN Terms#

Term, Definition table
TermDefinition
Ophthalmic fundus cameraAn electrically-powered optical device intended to be used to create digital colour photographic images/video of the ocular fundus (interior eye surface opposite the lens) through the pupil, to aid in diagnosing and monitoring retinal pathology; it may also be used for images/video of the anterior chamber. The image/video is typically transferred to a computer for display on its screen and/or for storage in a database. This device is also known as a retinal camera.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Depth520Millimeter
Height620Millimeter
Weight35.5Kilogram
Width400Millimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity35 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Storage Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-15 Degrees Celsius55 Degrees Celsius

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
692281073
Device count
1
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04987646807575KOWA nonmyd 8K9L61K2016-09-16
04987646810476KOWA SL-19SL192BK/W2024-10-08
04987646810223KOWA SL-19SL191BK/W2023-01-10
04987646810032KOWA SL-19SL191K/W2022-12-07
04987646810049KOWA SL-19SL191K/A2022-12-07
04987646810056KOWA SL-19SL191K/G2022-12-07
04987646810063KOWA SL-19SL191K/P2022-12-07
04987646810070KOWA SL-19SL191K/B2022-12-07
04987646804031KOWA SL-15SL150K2016-09-16
04987646806905KOWA SL-17SL170K/W2016-09-16
04987646806912KOWA SL-17SL170K/A2016-09-16
04987646806929KOWA SL-17SL170K/G2016-09-16
04987646806936KOWA SL-17SL170K/P2016-09-16
04987646809128KOWA nonmyd AFK9L64K2020-01-15
04987646807728KOWA DR-1αDE2K2019-06-10
04987646808923KOWA VK-2sVK28K2019-06-10
04987646808930KOWA VK-2sVK28UE2019-06-10
04987646808947KOWA VK-2sVK28U2E2019-06-10
04987646805113KOWA AP-7000FT10K2019-01-08
04987646800583KOWA GENESIS-DfK9L51BK2016-09-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
10857253006085Phoenix ICON GO Control BoxPhoenix ClinicalHKI2026-05-14
00857253006019ICON HandpiecePhoenix ClinicalHKI2026-04-03
00857253006033FA ModulePhoenix ClinicalHKI2026-04-03
00857253006071DiffuserPhoenix ClinicalHKI2026-04-03
00857253006101Phoenix ICON with Training KitPhoenix ClinicalHKI2026-04-03
00857253006118Phoenix ICON & FA Module with Training KitPhoenix ClinicalHKI2026-04-03
00857253006132Phoenix ICON GO with Training KitPhoenix ClinicalHKI2026-04-03
00857253006149Phoenix ICON GO & FA Module with Training Kit Phoenix ClinicalHKI2026-04-03
05713315011597RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011641RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011924RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011931RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011948RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
05713315011962RetCam EnvisionNatus Medical Denmark ApSHKI2026-02-10
06430046261006Optomed Smartscope FAOptomed OyHKI2025-12-12
06430046260597Smartscope Pro full setOptomed OyHKI2025-11-13
06430046260689Smartscope Pro retinal setOptomed OyHKI2025-11-13
045601262691023D OPTICAL COHERENCE TOMOGRAPHY 3D OCT-1(Type:Maestro2)TOPCON CORPORATIONHKI2025-09-11
00860014304507OptainOptain Health, Inc.HKI2025-07-07
00860010658109Fundus PhotoFundus PhotoHKI2025-03-31
03664188000589ZEISSLUNEAU TECHNOLOGY OPERATIONSHKI2025-03-11
00860000249584Verily Numetric Retinal Camera VERILY LIFE SCIENCES LLCHKI2025-02-24
00852788008019NeolightNEOLIGHT LLCHKI2025-01-26
00852788008026NeolightNEOLIGHT LLCHKI2025-01-26
00852788008040NeolightNEOLIGHT LLCHKI2025-01-26
00852788008057NeolightNEOLIGHT LLCHKI2025-01-26
00852788008064NeolightNEOLIGHT LLCHKI2025-01-26
00852788008071NeolightNEOLIGHT LLCHKI2025-01-26
10852788008085NeolightNEOLIGHT LLCHKI2025-01-26
20852788008020NeolightNEOLIGHT LLCHKI2025-01-26