X-ray beam limiting device
- Primary DI
- 04987670101670
- Brand
- X-ray beam limiting device
- Company
- CANON INC.
- Model
- BLR-15AA
- Published
- 2017-04-11
- Public version status
- Update
- Distribution status
- In Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
Contact Domains#
Product Codes#
| Code | Name |
|---|---|
| KPW | Device, beam limiting, x-ray, diagnostic |
Product Code Classifications#
| Code | Device | Specialty | Class |
|---|---|---|---|
| KPW | Device, Beam Limiting, X-Ray, Diagnostic | Radiology | 2 |
Premarket Submissions#
| Submission | Supplement |
|---|---|
| K133553 | 000 |
Premarket Details#
Identifiers And Packaging#
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| 04987670101670 | Primary | GS1 | 0 |
Alternate GTIN / UPC / EAN Codes
| Source identifier | GTIN-14 normalized | EAN-13 |
|---|---|---|
| 04987670101670 | 04987670101670 | 4987670101670 |
GMDN Terms#
| Term | Definition |
|---|---|
| Automatic-aperture-control diagnostic x-ray system collimator | A standard, diagnostic x-ray beam-limiting and shaping device that includes an automatically controlled motorized shutter mechanism. It is designed to adjust the shutters so that the x-ray beam shape matches the size of the film cassette in the holder and is attached to the beam exit port of a diagnostic x-ray system tube housing assembly. It typically includes a light-centring device that is used to project a light field onto the patient that is coincident with the x-ray beam in order to centre the tube over the film cassette. It is used to limit the effects of scattered radiation on image quality and to provide patient protection by eliminating exposure to non-target body areas. |
Sterilization Methods#
| Method |
|---|
Contacts#
| Phone | |
|---|---|
| +1-8004211968 | xxx@xxx.xxx |
Regulatory Flags#
- DUNS number
- 690549662
- Device count
- 1
- Serial number
- true
Other Devices From This Company#
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 04987670100222 | INTERVENTIONAL ANGIOGRAPHY SYSTEM | INFX-8000V | 2016-09-01 | |
| 04987670101359 | 4ch Flex SPEEDER | MJAJ-197A | 2016-09-01 | |
| 04987670102493 | Vitrea Software Toshiba Package | VSTP-001A | 2018-03-02 | |
| 04987670103360 | Vantage Orian | MRT-1550 | 2018-11-30 | |
| 04987670105937 | DIAGNOSTIC ULTRASOUND SYSTEM | CUS-AME00 | 2026-06-01 | |
| 04987670106194 | DIAGNOSTIC ULTRASOUND SYSTEM | CUS-ABE00 | 2026-06-01 | |
| 04987670105579 | Aquilion ONE | TSX-308A | 2025-01-09 | |
| 04987670103797 | CT SCANNER | TSX-306A | 2021-11-01 | |
| 04987670100741 | DIAGNOSTIC ULTRASOUND SYSTEM | TUS-X100S | 2016-09-01 | |
| 04987670100734 | DIAGNOSTIC ULTRASOUND SYSTEM | TUS-X100 | 2016-09-01 | |
| 04987670100758 | DIAGNOSTIC ULTRASOUND SYSTEM | TUS-X200 | 2016-09-01 | |
| 04987670100765 | DIAGNOSTIC ULTRASOUND SYSTEM | TUS-X200S | 2016-09-01 | |
| 04987670106095 | Aquilion Serve SP | TSX-307B | 2024-07-04 | |
| 04987670102721 | PHASED ARRAY TRANSDUCER | PSU-60ST | 2026-03-01 | |
| 04987670102745 | LINEAR ARRAY TRANSDUCER | PLU-1003ST | 2026-03-01 | |
| 04987670102752 | LINEAR ARRAY TRANSDUCER | PLU-805ST | 2026-03-01 | |
| 04987670102769 | PHASED ARRAY TRANSDUCER | PSU-30ST | 2026-03-01 | |
| 04987670102783 | LINEAR ARRAY TRANSDUCER | PLU-704ST | 2026-03-01 | |
| 04987670102806 | CW DOPPLER PENCIL TRANSDUCER | PC-20ST | 2026-03-01 | |
| 04987670102813 | DIAGNOSTIC ULTRASOUND SYSTEM | TUS-VC100 | 2026-03-01 |
Other Devices Sharing Product Codes#
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 04589607250019 | NA | YOSHIDA DENZAI KOGYO CO., LTD. | KPW | 2017-09-13 |
| 04056869011554 | Collimator ML01 II | Siemens Healthcare GmbH | KPW | 2017-02-02 |
| 04056869011578 | Collimator AL02 II eL | Siemens Healthcare GmbH | KPW | 2016-10-23 |
| 08057737120015 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120114 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120213 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120312 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120411 | Philips Medical Systems DMC | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 40889978154117 | X-ray Beam Filter Kit | CARESTREAM HEALTH, INC. | KPW | 2016-09-16 |
| 60889978154111 | X-ray Beam Filter Kit | CARESTREAM HEALTH, INC. | KPW | 2016-09-16 |
| 08058776050141 | Ralco srl | RALCO SRL | KPW | 2016-08-05 |
| 08058776050158 | Ralco srl | RALCO SRL | KPW | 2016-08-05 |
| 08058776050189 | Ralco srl | RALCO SRL | KPW | 2016-08-05 |
| 08058776050011 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050028 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050066 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050073 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050097 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050103 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050134 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |