Collimator AL02 II eL
- Primary DI
- 04056869011578
- Brand
- Collimator AL02 II eL
- Company
- Siemens Healthcare GmbH
- Model
- 10092614
- Published
- 2016-10-23
- Public version status
- Update
- Distribution status
- In Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
- Rx
- true
Contact Domains#
Product Codes#
| Code | Name |
|---|---|
| KPW | Device, beam limiting, x-ray, diagnostic |
Product Code Classifications#
| Code | Device | Specialty | Class |
|---|---|---|---|
| KPW | Device, Beam Limiting, X-Ray, Diagnostic | Radiology | 2 |
Identifiers And Packaging#
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| 04056869011578 | Primary | GS1 | 0 |
Alternate GTIN / UPC / EAN Codes
| Source identifier | GTIN-14 normalized | EAN-13 |
|---|---|---|
| 04056869011578 | 04056869011578 | 4056869011578 |
Storage And Handling#
| Type | Low | High | Condition |
|---|---|---|---|
| Handling Environment Atmospheric Pressure | 70 KiloPascal | 106 KiloPascal | |
| Handling Environment Humidity | 20 Percent (%) Relative Humidity | 75 Percent (%) Relative Humidity | |
| Handling Environment Temperature | 10 Degrees Celsius | 40 Degrees Celsius | |
| Storage Environment Atmospheric Pressure | 50 KiloPascal | 106 KiloPascal | |
| Storage Environment Humidity | 10 Percent (%) Relative Humidity | 95 Percent (%) Relative Humidity | |
| Storage Environment Temperature | -40 Degrees Celsius | 70 Degrees Celsius |
Sterilization Methods#
| Method |
|---|
Contacts#
| Phone | |
|---|---|
| +1(800)888-7436 | XX@XX.XX |
| +1(800)888-7436 | CONTACT@SIEMENS-HEALTHINEERS.COM |
Regulatory Flags#
- DUNS number
- 313217003
- Device count
- 1
- Premarket exempt
- true
- Serial number
- true
Other Devices From This Company#
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 04068151027273 | myAblation Guide | 10831405 | 10831405 | 2026-08-06 |
| 04056869991771 | myAblation Guide | 10831373 | 2026-05-11 | |
| 04068151018226 | syngo Application Software | 11831234 | 2026-05-15 | |
| 04056869964539 | syngo Application Software | 30000267 | 2024-11-15 | |
| 04056869964546 | syngo Application Software | 30000266 | 2024-01-01 | |
| 04056869262567 | syngo Application Software | 11328180 | 2022-10-10 | |
| 04056869247144 | syngo Dynamics VA20G | 10745650 | 2019-09-04 | |
| 04056869247175 | syngo Dynamics VA20G Packaging Label | 10745653 | 2019-09-04 | |
| 04056869274645 | AI-Rad Companion Organs RT | 11545290 | 2021-08-06 | |
| 04056869257969 | AI-Rad Companion Organs RT | 11294433 | 2021-02-18 | |
| 04056869272313 | syngo Dynamics | 11552103 | 2020-10-29 | |
| 04056869272320 | syngo Dynamics | 11552102 | 2020-10-29 | |
| 04056869256399 | syngo Dynamics | 11551643 | 2020-07-14 | |
| 04056869259901 | syngo Dynamics | 11551864 | 2020-07-14 | |
| 04056869248653 | syngo.Interventional | 11327988 | 2020-01-13 | |
| 04056869124162 | syngo Application Software | 11327667 | 2020-01-10 | |
| 04056869253244 | syngo Dynamics | 10745960 | 2019-12-12 | |
| 04056869096506 | syngo.plaza | 11293724 | 2019-05-01 | |
| 04056869001081 | syngo.plaza | 11064436 | 2016-09-23 | |
| 04056869004365 | syngo.plaza | 11249952 | 2016-09-24 |
Other Devices Sharing Product Codes#
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 04589607250019 | NA | YOSHIDA DENZAI KOGYO CO., LTD. | KPW | 2017-09-13 |
| 04987670101670 | X-ray beam limiting device | CANON INC. | KPW | 2017-04-11 |
| 04056869011554 | Collimator ML01 II | Siemens Healthcare GmbH | KPW | 2017-02-02 |
| 08057737120015 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120114 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120213 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120312 | Villa Sistemi Medicali | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 08057737120411 | Philips Medical Systems DMC | VILLA SISTEMI MEDICALI SPA | KPW | 2016-09-24 |
| 40889978154117 | X-ray Beam Filter Kit | CARESTREAM HEALTH, INC. | KPW | 2016-09-16 |
| 60889978154111 | X-ray Beam Filter Kit | CARESTREAM HEALTH, INC. | KPW | 2016-09-16 |
| 08058776050141 | Ralco srl | RALCO SRL | KPW | 2016-08-05 |
| 08058776050158 | Ralco srl | RALCO SRL | KPW | 2016-08-05 |
| 08058776050189 | Ralco srl | RALCO SRL | KPW | 2016-08-05 |
| 08058776050011 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050028 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050066 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050073 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050097 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050103 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |
| 08058776050134 | Ralco srl | RALCO SRL | KPW | 2016-08-04 |