Tendril™

Primary DI
05414734005715
Brand
Tendril™
Company
ST. JUDE MEDICAL, INC.
Model
SDX
Catalog number
1688T-100
Device description
Pacing Lead
Published
2017-04-10
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DTBpermanent pacemaker Electrode

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DTBPermanent Pacemaker ElectrodeCardiovascular3

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
P960013013

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
P960013013TENDRIL DX MODEL 1388T & 1388K ENDOCARDIAL PACING LEADSABBOTT MEDICAL1997-06-20NVN

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
05414734005715PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
05414734005715054147340057155414734005715

GMDN Terms#

Term, Definition table
TermDefinition
Endocardial pacing leadA sterile, implantable flexible wire with an electrode, insulated with non-conductive material except at its ends, which serves as an electrical conductor to transmit pacing impulses from an implanted pulse generator to the heart; it is not intended to conduct defibrillation impulses. It may also transmit electrical responses from the heart back to the pacemaker. The electrode end is normally placed through a vein to contact the wall of one of the heart's chambers (endocardium), and the other end is connected to the pacemaker. It is typically impregnated with a steroid (e.g., dexamethasone) intended to elute into the tissues to reduce inflammation.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length100Centimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Temperature-5 Degrees Celsius50 Degrees Celsius
Handling Environment Temperature23 Degrees Fahrenheit122 Degrees Fahrenheit
Storage Environment Temperature-5 Degrees Celsius50 Degrees Celsius
Storage Environment Temperature23 Degrees Fahrenheit122 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(855)478-5833customerservice@sjm.com

Regulatory Flags#

DUNS number
790268031
Device count
1
Combination product
true
Serial number
true
Manufacturing date on label
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
05415067052742Epic™ESP300-23ESP300-232026-07-08
05415067052759Epic™EELT-23AEELT-23A2026-07-08
05415067052766Epic™EELT-31MEELT-31M2026-07-08
05415067052780Epic™EELT-27MEELT-27M2026-07-08
05415067052797Epic™ESP300-25ESP300-252026-07-08
05415067052803Epic™ESP300-19ESP300-192026-07-08
05415067052810Epic™EELT-19AEELT-19A2026-07-08
05415067052827Epic™EELT-29MEELT-29M2026-07-08
05415067052834Epic™EELT-27AEELT-27A2026-07-08
05415067052858Epic™EELT-25AEELT-25A2026-07-08
05415067052865Epic™EELT-21AEELT-21A2026-07-08
05415067052872Epic™EELT-33MEELT-33M2026-07-08
05415067052889Epic™ESP300-27ESP300-272026-07-08
05415067052896Epic™EELT-25MEELT-25M2026-07-08
05415067052902Epic™ESP300-21ESP300-212026-07-08
05415067052964Epic™ESP1000-AESP1000-A2026-07-08
05415067052971Epic™EELT-1000MEELT-1000M2026-07-08
05415067052988Epic™EELT-1000AEELT-1000A2026-07-08
05415067054197NAEELT-19A-SEELT-19A-S2026-07-08
05415067054203NAEELT-29A-SEELT-29A-S2026-07-08

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00763000812058NAMEDTRONIC, INC.DTB2025-04-12
00763000840259N/AMEDTRONIC, INC.DTB2024-11-14
00763000180010Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180027Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180034Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180041Sprint Quattro Secure S MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180058Sprint Quattro Secure S MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180119Sprint Quattro Secure S MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180126Sprint Quattro Secure S MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180133Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180140Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180157Sprint Quattro Secure S™MEDTRONIC, INC.DTB2024-11-04
00763000180232Sprint Quattro Secure™MEDTRONIC, INC.DTB2024-11-04
00763000180249Sprint Quattro Secure™MEDTRONIC, INC.DTB2024-11-04
00763000180256Sprint Quattro Secure MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180263Sprint Quattro Secure MRI™ SureScan™MEDTRONIC, INC.DTB2024-11-04
00763000180355Sprint Quattro Secure™MEDTRONIC, INC.DTB2024-11-04
00763000740252SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2022-12-11
00763000740269SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2022-12-11
00763000740276SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2022-12-11
00763000059477NAMEDTRONIC, INC.DTB2018-12-28
00763000130794SelectSecure™ MRI SureScan™MEDTRONIC, INC.DTB2018-10-11
04035479157821EFH-6F-WBIOTRONIK SE & Co. KGDTB2017-11-22
04035479157838EFH-6F-WBIOTRONIK SE & Co. KGDTB2017-11-17
00643169410954CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00643169410961CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00643169448940CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00643169448957CapSure Sense MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-26
00763000014636CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20
00763000014650CapSureFix Novus MRI™ SureScan™MEDTRONIC, INC.DTB2017-10-20