Konmed

Primary DI
06970935830109
Brand
Konmed
Company
Shenzhen Konmed Technology Co., Ltd.
Model
KM-802
Device description
The proposed Electrodes with snap / Electrodes with pigtail are non-sterile laminated, flexible structures composed of materials commonly used in this application: The electrodes are designed for single-patient application use. Because of the adhesive nature of the biocompatible hydro gel, no securing materials are required to secure the product to the patient’s skin. The proposed product mainly consists of electrode pad and snap or pigtail. The electrode pad is available in Round Shape Electrode, Rectangular Shape Electrode, Palm Shape Electrode, Elliptical Shape Electrode, and Calabash Shape Electrode. All patient contacted materials are complied with the biocompatibility standards ISO 10993-5 (Cytotoxicity) and ISO 10993-10 (Irritation and Sensitization).
Published
2018-01-25
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
OTC
true

Product Codes#

Code, Name table
CodeName
GXYElectrode, Cutaneous

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GXYElectrode, CutaneousNeurology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K171722000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K171722000Electrodes with snap / Electrodes with pigtailShenzhen Konmed Technology Co., Ltd.2018-01-10GXY

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
06970935830109PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
06970935830109069709358301096970935830109

GMDN Terms#

Term, Definition table
TermDefinition
Transcutaneous electrical stimulation electrodeA non-sterile electrical conductor intended to be attached to a patient's skin (noninvasive) to provide therapeutic electrical stimuli through the body surface [e.g., transcutaneous electrical nerve stimulation (TENS), electrical muscle stimulation, cranial electrotherapy stimulation (CES)]. It is typically a flat, flexible, conductive pad with an adhesive (e.g., gel), or a preformed shape/mechanism designed for attachment to a particular body part (e.g., earclip), connected to a conductive wire. This is a single-patient device that may be reapplied to the patient over a short term (single-use) before being discarded.

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
544436531
Device count
1
Lot or batch
true
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
06970935830529KONMED /PelvifineKM508B2025-09-30
06970935830710PelvifineKM5002025-02-18
06970935830536KONMED /PelvifineKM5302021-10-25
06970935830543KONMED /PelvifineKM5312021-10-25
06970935830482KONMEDKM-5022024-03-05
06970935830499KONMEDKM-5032024-03-05
06970935830642KONMEDKM-5042024-03-05
06970935830659KONMEDKM-5052024-03-05
06970935830666KONMEDKM-5062024-03-05
06970935830673KONMEDKM-5072024-03-05
06970935830680KONMEDKM-50132024-03-05
06970935830697KONMEDKM-50182024-03-05
06970935830567KONMED /PelvifineKM530B2022-08-24
06970935830574KONMED /PelvifineKM531B2022-08-24
06970935830581KONMED /PelvifineKM5362022-08-24
06970935830598KONMED /PelvifineKM5372022-08-24
06970935830079KonmedKM-8032018-01-25
06970935830086KonmedKM-8082018-01-25
06970935830093KonmedKM-8012018-01-25
06970935830116KonmedKM-8062018-01-25

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00816312028072Rhythmlink®RHYTHMLINK INTERNATIONAL, LLCGXY2026-06-01
08057971594733Remote Wave ElectrodeBIONIT LABS SRLGXY2026-03-18
08720791375911CadwellTechnomed Engineering B.V.GXY2025-03-12
08057971592685Wave ElectrodeBIONIT LABS SRLGXY2025-01-21
08720791377564NeuroradiumTechnomed Engineering B.V.GXY2024-11-22
08720791377595NeuroradiumTechnomed Engineering B.V.GXY2024-11-22
08720791375591CadwellTechnomed Engineering B.V.GXY2024-10-04
08720791375614CadwellTechnomed Engineering B.V.GXY2024-10-04
08720791375638CadwellTechnomed Engineering B.V.GXY2024-10-04
08720791375652CadwellTechnomed Engineering B.V.GXY2024-10-04
08720791375676CadwellTechnomed Engineering B.V.GXY2024-10-04
08720791374426NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374440NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374457NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374471NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374495NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374518NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374532NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374556NeuroguardTechnomed Engineering B.V.GXY2024-05-22
08720791374693MagstimTechnomed Engineering B.V.GXY2024-05-22
08720791372125CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372149CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372163CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372187CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372200CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372224CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372248CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372262CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372286CadwellTechnomed Engineering B.V.GXY2024-05-02
08720791372309CadwellTechnomed Engineering B.V.GXY2024-05-02