4KINSIGHT UHD Fluorescence Imaging System

Primary DI
06971381251456
Brand
4KINSIGHT UHD Fluorescence Imaging System
Company
Scivita Medical Technology Co., Ltd.
Model
4KIR01
Device description
The Scivita 4KINSIGHT ICG Imaging System consists of a 4KINSIGHT UHD Fluorescence Imaging System, a Near-Infrared LED Light Source, and a 4K UHD LAPAROSCOPE.Upon intravenous administration of TRADENAME (ICG drug product), the Scivita 4KINSIGHT ICG Imaging System is used with TRADENAME to perform intraoperative fluorescence angiography, and it is also indicated for use in fluorescence imaging of biliary ducts, and when indicated, during intraoperative cholangiography.The Scivita 4KINSIGHT ICG Imaging System is indicated for use to provide real time endoscopic visible and near-infrared fluorescence imaging. The Scivita 4KINSIGHT ICG Imaging System enables surgeons to perform minimally invasive surgery using standard endoscope visible light as well as visual assessment of vessels, blood flow and related tissue perfusion, and at least one of the major extra-hepatic bile ducts (cystic duct, common bile duct or common hepatic duct), using near-infrared imaging.Fluorescence imaging of biliary ducts with the Scivita 4KINSIGHT ICG Imaging System is intended for use with standard of care white light, and when indicated, intraoperative cholangiography. The device is not intended for standalone use for biliary duct visualization.Upon interstitial administration of TRADENAME (ICG drug product), the Scivita 4KINSIGHT ICG Imaging System is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes.
Published
2023-05-19
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
GCJLaparoscope, General & Plastic Surgery
IZISystem, X-Ray, Angiographic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2
IZISystem, X-Ray, AngiographicRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K221252000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K221252000Scivita 4KINSIGHT ICG Imaging SystemScivita Medical Technology Co., Ltd.2023-01-13GCJ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
06971381251456PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
06971381251456069713812514566971381251456

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic video image processing unitAn electrically-powered device designed to receive and process the electronic signals sent from a video endoscope or endoscopic video camera; it does not include the endoscope nor light source and is not designed to control the endoscope. It may have additional features which compensate for/enhance the colour and light qualities provided. The resulting picture images are sent to and shown on a visual display unit (VDU), typically to assist the endoscope operator with an ongoing intervention and often to allow the patient visualization of the process; the images can be recorded on a video recorder or stored on computerized media.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity20 Percent (%) Relative Humidity80 Percent (%) Relative Humidity
Handling Environment Temperature5 Degrees Celsius28 Degrees Celsius
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Atmospheric Pressure700 KiloPascal1060 KiloPascal
Storage Environment Humidity20 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-40 Degrees Celsius55 Degrees Celsius

Sterilization Methods#

Method table
Method
High-level Disinfectant

Regulatory Flags#

DUNS number
544519831
Device count
1
Serial number
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
06971381252736Single-use Extraction BasketsEBF-1529CG2024-12-06
06971381252743Single-use Extraction BasketsEBF-1511CG2024-12-06
06971381252750Single-use Extraction BasketsEBF-1511SG2024-12-06
06971381252767Single-use Extraction BasketsEBF-1506SG2024-12-06
06971381252774Single-use Extraction BasketsEBF-1506CG2024-12-06
06971381252781Single-use Extraction BasketsEBF-1507SG2024-12-06
06971381252798Single-use Extraction BasketsEBF-1507CG2024-12-06
06971381252804Single-use Extraction BasketsEBF-1508SG2024-12-06
06971381252811Single-use Extraction BasketsEBF-1508CG2024-12-06
06971381252828Single-use Extraction BasketsEBF-2029SG2024-12-06
06971381252835Single-use Extraction BasketsEBF-2029CG2024-12-06
06971381252903Single-use Extraction BasketsEBF-2006SG2024-12-06
06971381252910Single-use Extraction BasketsEBF-2006CG2024-12-06
06971381252927Single-use Extraction BasketsEBF-2007SG2024-12-06
06971381252934Single-use Extraction BasketsEBF-2007CG2024-12-06
06971381252941Single-use Extraction BasketsEBF-2008SG2024-12-06
06971381252958Single-use Extraction BasketsEBF-2008CG2024-12-06
06971381252729Single-use Extraction BasketsEBF-1529SG2024-12-06
06971381253146Single-use Biopsy ForcepsBFUW-1029P-YG2023-12-28
06971381253153Single-use Biopsy ForcepsBFTW-1629E-YG2023-12-28

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00198506044366ELMEDELMED INCORPORATEDGCJ2026-06-09
00812231033906PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08
00812231033913PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08
00812231033920PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08
00812231034095PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08
00812231034101PixaSANTA BARBARA IMAGING SYSTEMS, INC.GCJ2026-06-08
04717480900336Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900343Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900350Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900367Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900398Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900404Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900763Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900770Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900787Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
04717480900800Inno-PortTAIWAN SURGICAL CORPORATIONGCJ2026-06-08
E496C05HPDH0Handle for pneumodissection HookAB MEDICAGCJ2026-06-08
E496C05IDCH20ST1Hook insert and tube for pneumodissection D=5,0mm Lg=20cm, sterile single useAB MEDICAGCJ2026-06-08
E496C05IDCH33ST1Hook insert and tube for pneumodissection D=5,0mm Lg=33cm, sterile single useAB MEDICAGCJ2026-06-08
E496C35IDCH20ST1Hook insert and tube for pneumodissection D=3,5mm Lg=20cm, sterile single useAB MEDICAGCJ2026-06-08
E496C35IDCH33ST1Hook insert and tube for pneumodissection D=3,5mm Lg=33cm, sterile single useAB MEDICAGCJ2026-06-08
00198506091414ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-05
00198506091421ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-05
00198506091438ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-05
00198506091247ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-03
00198506091254ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-06-03
00192896123427TrocarSONTEC INSTRUMENTS, INC.GCJ2026-06-02
00192896123434Flexible Trocar SleeveSONTEC INSTRUMENTS, INC.GCJ2026-06-02
E496C35BTU200C35-Bipolar Tube L 20cm D 3,5mmAB MEDICAGCJ2026-05-28
E496C35IBDM200C35- Bipolar Maryland Insert L20cm D 3,5mmAB MEDICAGCJ2026-05-28