InModeRF hand piece

Primary DI
07290019863410
Brand
InModeRF hand piece
Company
INMODE M.D LTD
Model
HP1722B6A
Catalog number
HP1722B6A
Device description
Fractional RF Quantum Handpiece which comprises canula with active electrodes, handle, cable and connector Handpiece HP1722B6A has a canula diameter of 2mm and 17cm long. Maximal RF power is 35W.
Published
2026-04-16
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K251254000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K251254000Ignite RF SystemInMode , Ltd.2026-01-15GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
07290019863410PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
07290019863410072900198634107290019863410

GMDN Terms#

Term, Definition table
TermDefinition
Radio-frequency fat liquefaction systemAn assembly of devices using radio-frequency (RF) energy for simultaneous adipose tissue liquefaction, blood vessel coagulation, and skin tightening during a radio-frequency-assisted liposuction (RFAL) procedure [lipectomy], typically performed for body contouring. The system consists of an RF-generating control unit that supplies RF energy to a dedicated applicator (handpiece) and provides continuous tissue temperature monitoring; impedance and power monitoring with tissue overheating safety systems; the RF applicator; and a foot-switch to control the RF energy supply. The liquified tissue is aspirated with an independent external suction system.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Handling Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius35 Degrees Celsius
Storage Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Storage Environment Humidity0 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature10 Degrees Celsius35 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
1-887-367-4556contact@inmode.com

Regulatory Flags#

DUNS number
600417351
Device count
1
DM exempt
true
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
07290019863359ApexRF ApplicatorAG614409AAG614409A2025-06-04
07290019863205Morpheus8 90 ApplicatorAG613133AAG613133A2026-04-19
07290019863212Morpheus8 90 TipAG613135AAG613135A2026-04-19
07290019863274InMode RF hand pieceHP060999AHP060999A2025-02-20
07290019863281InMode RF hand pieceHP101396AHP101396A2025-02-20
07290019863298InMode RF hand pieceHP172296AHP172296A2025-02-20
07290019863083Morpheus8 Resurfacing TIPAG613051AAG613051A2024-08-22
07290019863090Morpheus8 Prime 12 pin TIPAG613052AAG613052A2024-08-22
07290019863106Morpheus8 40 pin TIPAG613053AAG613053A2024-08-22
07290019863113Morpheus8 24 pin TIPAG613054AAG613054A2024-08-22
07290019863120Morpheus8 Burst ApplicatorAG613055AAG613055A2024-08-21
07290019863137Morpheus8 Burst Deep ApplicatorAG613056AAG613056A2024-08-21
07290019863076InModeRF hand pieceHP2539B6AHP2539B6A2024-08-08
07290019863045InMode RF hand pieceHP102206AHP102206A2024-04-25
07290019863052InMode RF hand pieceHP253966AHP253966A2024-04-25
07290019863069InModeRF hand pieceHP1022B6AHP1022B6A2024-08-08
07290019863250Ignite RF SystemAG613237AAG613237A2024-03-24
07290016633689Transform (T3 Applicator) AG609899A AG609899A 2022-10-27
07290016633498Evolve SystemAG608081AAG608081A2022-10-26
07290016633252InModeAG606666AAG606666A2017-03-14

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776434328MillenniumAvalign Technologies, Inc.GEI2026-10-06
B382SD134188100Surgical DirectSurgical Direct, Inc.GEI2026-10-06
B382SD13798330Surgical DirectSurgical Direct, Inc.GEI2026-10-06
00190776433284MillenniumAvalign Technologies, Inc.GEI2026-10-05
00848657078467AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657078474AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657083782AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657083812AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657083843AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657083874AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657083898AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657084956AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657084963AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657084970AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
00848657087698AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-10-05
04953170474958THUNDERBEAT 5 mm,45 cm, Front-actuated Grip Type SOLYMPUS MEDICAL SYSTEMS CORP.GEI2026-10-05
04953170474965THUNDERBEAT 5 mm,45 cm, Front-actuated Grip Type SOLYMPUS MEDICAL SYSTEMS CORP.GEI2026-10-05
04953170474972THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type SOLYMPUS MEDICAL SYSTEMS CORP.GEI2026-10-05
04953170474989THUNDERBEAT 5 mm,35 cm,Front-actuated Grip Type SOLYMPUS MEDICAL SYSTEMS CORP.GEI2026-10-05
04953170474996THUNDERBEAT 5 mm,20 cm,Front-actuated Grip Type SOLYMPUS MEDICAL SYSTEMS CORP.GEI2026-10-05
04953170475009THUNDERBEAT 5 mm,20 cm,Front-actuated Grip Type SOLYMPUS MEDICAL SYSTEMS CORP.GEI2026-10-05
00190776433062MillenniumAvalign Technologies, Inc.GEI2026-10-01
10884521740150LigaSureCovidien LPGEI2026-10-01
00190776432980MillenniumAvalign Technologies, Inc.GEI2026-09-30
B382SD070823101310Surgical DirectSurgical Direct, Inc.GEI2026-09-30
10884450452353STAR™Merit Medical Systems, Inc.GEI2026-09-29
00190776432645MillenniumAvalign Technologies, Inc.GEI2026-09-28
00197998302718Solventum™Solventum US LLCGEI2026-09-25
00724995269586Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269951Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25