Raypilot Matching Network
- Primary DI
- 07350007956040
- Brand
- Raypilot Matching Network
- Company
- Micropos Medical AB (Publ)
- Model
- 1
- Catalog number
- 6004
- Device description
- Raypilot Matching Network is connected between Raypilot Hypocath and Raypilot Transmitter Cable. The Raypilot Matching Network matches the resonance capacitance of the transmitter with the inductance of the antennas of the Raypilot Receiver.
- Published
- 2023-04-04
- Public version status
- Update
- Distribution status
- In Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
- Rx
- true
Contact Domains#
Product Codes#
| Code | Name |
|---|---|
| IYE | Accelerator, Linear, Medical |
Product Code Classifications#
| Code | Device | Specialty | Class |
|---|---|---|---|
| IYE | Accelerator, Linear, Medical | Radiology | 2 |
Premarket Submissions#
| Submission | Supplement |
|---|---|
| K203722 | 000 |
Premarket Details#
Identifiers And Packaging#
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| 07350007956040 | Primary | GS1 | 0 |
Alternate GTIN / UPC / EAN Codes
| Source identifier | GTIN-14 normalized | EAN-13 |
|---|---|---|
| 07350007956040 | 07350007956040 | 7350007956040 |
GMDN Terms#
| Term | Definition |
|---|---|
| Radiation therapy invasive marker lesion localization system | An assembly of noninvasive devices intended to monitor the position of a patient's tumour/lesion relative to the isocenter of a radiation therapy system, to assist with their alignment during treatment planning or a therapeutic procedure. It localizes the position of invasive markers [e.g., electromagnetic (EM) signal transmitters, radiopaque markers] (not included) which have been introduced/implanted in or near the target site prior to treatment. It typically includes an EM receiver and dedicated software. |
Storage And Handling#
| Type | Low | High | Condition |
|---|---|---|---|
| Handling Environment Atmospheric Pressure | 70 KiloPascal | 106 KiloPascal | |
| Handling Environment Humidity | 30 Percent (%) Relative Humidity | 70 Percent (%) Relative Humidity | |
| Handling Environment Temperature | 10 Degrees Celsius | 40 Degrees Celsius | |
| Storage Environment Atmospheric Pressure | 70 KiloPascal | 106 KiloPascal | |
| Storage Environment Humidity | 30 Percent (%) Relative Humidity | 70 Percent (%) Relative Humidity | |
| Storage Environment Temperature | 10 Degrees Celsius | 40 Degrees Celsius |
Sterilization Methods#
| Method |
|---|
Contacts#
| Phone | |
|---|---|
| +46317608005 | info@micropos.se |
Regulatory Flags#
- DUNS number
- 350533316
- Device count
- 1
- DM exempt
- true
- Lot or batch
- true
- Serial number
- true
- Manufacturing date on label
- true
Other Devices From This Company#
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 07350007951045 | Raypilot Hypocath | 1 | 1004 | 2023-04-04 |
| 07350007952202 | Raypilot Receiver | 1 | 2020 | 2025-03-12 |
| 07350007956026 | Raypilot System Cable | 1 | 6002 | 2025-03-12 |
| 07350007951052 | Raypilot Viewcath | 1 | 1005 | 2023-04-04 |
| 07350007952219 | Raypilot Extension Plate | 1 | 2021 | 2023-04-04 |
| 07350007953049 | Raypilot Software | 1 | 3004 | 2023-04-04 |
| 07350007954053 | Raypilot Quality Control Kit | 1 | 4005 | 2023-04-04 |
| 07350007954060 | Raypilot Transmitter Tester | 1 | 4006 | 2023-04-04 |
| 07350007954077 | Raypilot Table Displacement Meter | 1 | 4007 | 2023-04-04 |
| 07350007956019 | Raypilot Transmitter Cable | 1 | 6001 | 2023-04-04 |
| 07350007956033 | Raypilot Power Box | 1 | 6003 | 2023-04-04 |
Other Devices Sharing Product Codes#
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 08057014731224 | LIAC HWL | S.I.T. SORDINA IORT TECHNOLOGIES SPA | IYE | 2026-04-30 |
| 08057014731231 | LIAC HWL | S.I.T. SORDINA IORT TECHNOLOGIES SPA | IYE | 2026-04-30 |
| 08720168162595 | Mask DSPS®-PROSH set/5 | MACROMEDICS B.V. | IYE | 2026-04-23 |
| 08720168162564 | DSPS-Prominent® Cradle-II | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162571 | Mask DSPS®-PROSHVRL set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162618 | Mask DSPS®-PROSHL set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162649 | Mask DSPS®-PROSHVR set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162748 | Mask DSPS®-PROH, set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162755 | Mask DSPS®-PRO, set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162779 | DSPS-Prominent® Cradle-III | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162786 | DSPS-Prominent® Cradle-IV | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162793 | DSPS-Prominent® Cradle-VI | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162854 | Mask DSPS®-PROSCVRL set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162861 | Mask DSPS®-PROSC set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162878 | Mask DSPS®-PROSCVR set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168162885 | Mask DSPS®-PROSCL set/5 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168163325 | DSPS-Prominent® Cradle-VII | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168163356 | DSPS-Prominent® SH profile set/2 | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168163387 | DSPS PRO Mask Shim Set HNS | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168163394 | DSPS PRO Mask Shim Set HO | MACROMEDICS B.V. | IYE | 2026-04-22 |
| 08720168160140 | DSPS-Prominent® baseplate | MACROMEDICS B.V. | IYE | 2026-04-21 |
| 08720168162557 | DSPS-Prominent® Cradle-I | MACROMEDICS B.V. | IYE | 2026-04-21 |
| 08720168162908 | Handgrips HNS, set/2 | MACROMEDICS B.V. | IYE | 2026-04-21 |
| EPTWS070031Q5200 | VERIQA | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | IYE | 2026-04-17 |
| EPTWS0700300 | PQASoft | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | IYE | 2026-04-15 |
| EPTWTM600220 | microSilicon X | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | IYE | 2026-04-15 |
| EPTWTM600230 | microSilicon | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | IYE | 2026-04-15 |
| EPTWTN600220 | microSilicon X | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | IYE | 2026-04-15 |
| EPTWTN600230 | microSilicon | PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH | IYE | 2026-04-15 |