Primary DI
07613327467871
Brand
NA
Company
STRYKER CORPORATION
Model
4605000000
Catalog number
4605-000-000
Device description
System 9 Cordless Driver Handpiece
Published
2021-06-15
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
HWEINSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT
OUGMedical device data system

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HWEInstrument, Surgical, Orthopedic, Ac-Powered Motor And Accessory/AttachmentGeneral, Plastic Surgery1
OUGMedical Device Data SystemGeneral Hospital1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
07613327467871PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
07613327467871076133274678717613327467871

GMDN Terms#

Term, Definition table
TermDefinition
Rechargeable battery-powered surgical power tool system motorA compact engine that draws power from a rechargeable battery pack intended to convert electrical energy into a non-dedicated mechanical energy to perform a variety of surgical procedures that include drilling, sawing, and inserting involving bones and tough tissues (e.g., cartilage, ligaments). It is typically a pistol-like handpiece that connects to a variety of surgical power tool attachments. The device may be cannulated to permit use of a guidewire. It may be operated with a hand- or foot-switch; it is not intended to draw power from a line-powered control unit. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Handling Environment Humidity10 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature-20 Degrees Celsius40 Degrees Celsius
Storage Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)253-3210Inst.Stryker.cs@Stryker.com

Regulatory Flags#

DUNS number
196548481
Device count
1
Premarket exempt
true
Serial number
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
07613327524475Optablate97000151009700-015-1002022-09-23
07613327638233Omnicurve10320150001032-015-0002024-09-03
00857037006075LATERALATSYS24LATSYS242020-01-14
00857037006037LATERALATSYS20LATSYS202020-01-08
07613327060058Precision Ideal Eyes05028190100502-819-0102016-09-23
07613327006223ARIA48755700487557002019-11-20
07613327006919ES2 SPINAL SYSTEM48280082482800822019-11-20
07613327006926ES2 SPINAL SYSTEM48280083482800832019-11-20
07613327006940ES2 SPINAL SYSTEM48280086482800862019-11-20
07613327006957ES2 SPINAL SYSTEM48280087482800872019-11-20
07613327007114ES2 SPINAL SYSTEM48280311482803112019-11-25
07613327007558XIA 348237078482370782019-11-25
07613327007565XIA 348237079482370792019-11-25
07613327067088ACCULIF8003578003572016-09-24
07613327067095ACCULIF8003478003472016-09-24
07613327114799XIA 4.5 EVOLUTION48138140481381402019-11-21
07613327114812XIA 4.5 EVOLUTION48138011R48138011R2019-11-20
07613327114843XIA 4.5 EVOLUTION48138011L48138011L2019-11-20
07613327114850XIA 4.5 EVOLUTION48138101481381012019-11-21
07613327114874ES2 SPINAL SYSTEM48280178482801782019-11-20

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
03700879515687Airlock®NOVASTEPHWE2026-08-25
04580826921209PENTAX MedicalPENTAX MEDICAL CORPORATIONOUG2026-08-25
08800038061286EZXIMEDICOM CO., LTD.HWE2026-08-25
00850083430108SOLOFIX Provisional Fixation SystemAXIA ORTHOPEDICS, INC.HWE2026-08-17
00850083430122SOLOFIX Provisional Fixation SystemAXIA ORTHOPEDICS, INC.HWE2026-08-17
00850083430139SOLOFIX Provisional Fixation SystemAXIA ORTHOPEDICS, INC.HWE2026-08-17
00193982616472ORTHOPEDIC MANUAL SURGICAL INSTRUMENTGLOBUS MEDICAL, INC.HWE2026-08-14
00193982616489ORTHOPEDIC MANUAL SURGICAL INSTRUMENTGLOBUS MEDICAL, INC.HWE2026-08-14
00850015699160Canary Flight PlanCanary Medical USA LLCOUG2026-08-07
00850015699177Canary Recovery CurveCanary Medical USA LLCOUG2026-08-07
03701089527897AMPLITUDEAMPLITUDE SASHWE2026-07-29
03701089542326AMPLITUDEAMPLITUDE SASHWE2026-07-29
00841731153135ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153142ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153159ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153166ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153173ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153180ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153197ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153203ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153210ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153227ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153234ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
00841731153241ARTEMIS TAKEDOWNVILEX LLCHWE2026-07-22
04048675544227Connectivity Converter CC300Drägerwerk AG & Co. KGaAOUG2026-07-17
04260658860258myoncareONCARE GmbHOUG2026-07-17
00840241600443Kestra Provided Device Patient ApplicationKestra Medical Technologies, Inc.OUG2026-07-16
00884400004871GoClinicMonitored Therapeutics, Inc.OUG2026-07-16
00884400085481GoMobileMonitored Therapeutics, Inc.OUG2026-07-16
04035479194192PatientApp 2.10.0BIOTRONIK SE & Co. KGOUG2026-07-16