NA

Primary DI
07613327504040
Brand
NA
Company
STRYKER CORPORATION
Model
5407-NF2-8CM
Catalog number
5407-NF2-8CM
Device description
NON FOOTED ATTACHMENT 8CM
Published
2021-07-08
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
HBEDRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED)

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HBEDrills, Burrs, Trephines & Accessories (Simple, Powered)Neurology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
07613327504040PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
07613327504040076133275040407613327504040

GMDN Terms#

Term, Definition table
TermDefinition
Drilling power tool attachment, basicA device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicated mechanical motion to perform a drilling function when an appropriate drill bit is inserted. It may include integral design features, e.g., have an angled head, be cannulated, have an attached Jacobs chuck, or have an extended body length to better suit a particular activity. It is typically made of high-grade stainless steel and synthetic materials. The device may be of the micro or macro design. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity10 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius27 Degrees Celsius
Storage Environment Atmospheric Pressure50 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+0018002533210inst.stryker.cs@stryker.com

Regulatory Flags#

DUNS number
196548481
Device count
1
DM exempt
true
Serial number
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
07613327524475Optablate97000151009700-015-1002022-09-23
07613327638233Omnicurve10320150001032-015-0002024-09-03
00857037006075LATERALATSYS24LATSYS242020-01-14
00857037006037LATERALATSYS20LATSYS202020-01-08
07613327060058Precision Ideal Eyes05028190100502-819-0102016-09-23
07613327006223ARIA48755700487557002019-11-20
07613327006919ES2 SPINAL SYSTEM48280082482800822019-11-20
07613327006926ES2 SPINAL SYSTEM48280083482800832019-11-20
07613327006940ES2 SPINAL SYSTEM48280086482800862019-11-20
07613327006957ES2 SPINAL SYSTEM48280087482800872019-11-20
07613327007114ES2 SPINAL SYSTEM48280311482803112019-11-25
07613327007558XIA 348237078482370782019-11-25
07613327007565XIA 348237079482370792019-11-25
07613327067088ACCULIF8003578003572016-09-24
07613327067095ACCULIF8003478003472016-09-24
07613327114799XIA 4.5 EVOLUTION48138140481381402019-11-21
07613327114812XIA 4.5 EVOLUTION48138011R48138011R2019-11-20
07613327114843XIA 4.5 EVOLUTION48138011L48138011L2019-11-20
07613327114850XIA 4.5 EVOLUTION48138101481381012019-11-21
07613327114874ES2 SPINAL SYSTEM48280178482801782019-11-20

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00816589021615Brasseler Twist DrillbitMONTERIS MEDICAL INCHBE2026-07-03
00816589021622Brasseler Twist DrillbitMONTERIS MEDICAL INCHBE2026-07-03
04589551366217P300-2A100NAKANISHI INC.HBE2026-06-26
04589551366262P300-2A120NAKANISHI INC.HBE2026-06-26
04589551366316P300-2S100NAKANISHI INC.HBE2026-06-26
04589551366361P300-2S120NAKANISHI INC.HBE2026-06-26
07630055505675PM2-A70Bien-Air Surgery SAHBE2023-02-09
07630055505682PM2-A150Bien-Air Surgery SAHBE2023-02-09
07630055505699PM2-S70Bien-Air Surgery SAHBE2023-02-09
07630055505705PM2-A95Bien-Air Surgery SAHBE2023-02-09
07630055505712PM2-A125Bien-Air Surgery SAHBE2023-02-09
07630055505729NANO MicromotorBien-Air Surgery SAHBE2023-02-09
07630055505750PM2-A70HDBien-Air Surgery SAHBE2023-02-09
07613327504019NASTRYKER CORPORATIONHBE2021-07-08
07613327504057NASTRYKER CORPORATIONHBE2021-07-08
10887587057026NASynthes GmbHHBE2019-02-22
04546540246332NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540246356NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540246387NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540246974NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540246981NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540251862NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540337818DELTAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540337825DELTAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540337900DELTAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540356499NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540356505NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540356512NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540356529NAStryker Leibinger GmbH & Co. KGHBE2016-08-24
04546540356536NAStryker Leibinger GmbH & Co. KGHBE2016-08-24