SXR / Saevo

Primary DI
07899581340758
Brand
SXR / Saevo
Company
Alliage S/A Indústrias Médico Odontológica
Model
AXR90 B
Catalog number
16000004377
Device description
Panoramic Only
Published
2024-02-23
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
OASX-Ray, Tomography, Computed, Dental

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
OASX-Ray, Tomography, Computed, DentalRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K223816000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K223816000Dental CT Scanner AXRAlliage S/A Industrias Medico Odontológica2023-04-07OAS

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
07899581340758PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
07899581340758078995813407587899581340758

GMDN Terms#

Term, Definition table
TermDefinition
Cone beam computed tomography system, head/neckA stationary assembly of mains electricity (AC-powered) devices intended to produce two- or three-dimensional (3-D) diagnostic digital x-ray images of the head/neck using cone beam computed tomography (CBCT). It consists of an x-ray source assembly, high-voltage generator, x-ray detector, processor, reconstruction software, and patient support device (e.g., seat, stabilizing bite block); the patient is typically scanned in an upright position by a rotating arm. It is typically intended for (but not limited to) dental and ear/nose/throat (ENT) applications.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity0 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-18 Degrees Celsius70 Degrees Celsius

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
898231451
Device count
1
Lot or batch
true
Serial number
true
Manufacturing date on label
true
Donation ID number
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
07899581339639Dental CT Scanner AXRAXR90160000040582023-10-18
07899581342707Delivery UnitSyncrus G2410000082932025-12-31
07899581342844Delivery UnitSyncrus G3410000083072025-12-31
07899581343186Delivery UnitSyncrus G3 H410000083092025-12-31
07899581343414Delivery UnitSyncrus G8 FE410000083492025-12-31
07899581343599Delivery UnitSyncrus G8 HE410000083502025-12-31
07899581343834Water UnitSyncrus G2410000081882025-12-31
07899581343933Water UnitSyncrus G2410000081842025-08-01
07899581343957Water UnitSyncrus G3410000081992025-08-01
07899581344015Water UnitSyncrus G4A410000082052025-08-01
07899581340925Dental ChairSyncrus G2410000081562025-07-25
07899581337437EAGLE X-RAYAXR60 S160000034952024-02-26
07899581340703EAGLE X-RAYAXR65 S160000043752024-02-26
07899581340642Dental CT Scanner AXRAXR120160000042552024-02-23
07899581340659Dental CT Scanner AXRAXR120160000042562024-02-23
07899581340734SXR / SaevoAXR90 B160000043702024-02-23
07899581340741SXR / SaevoAXR120 B160000043712024-02-23
07899581340765SXR / SaevoAXR90 B160000043782024-02-23
07899581340772SXR / SaevoAXR120 B160000043792024-02-23
07899581340789SXR / SaevoAXR120 B160000043802024-02-23

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08800016401936Green X 12 SEVATECH CO., LTD.OAS2026-06-01
08800016401943Green X 12 SEVATECH CO., LTD.OAS2026-06-01
60192155951237CS 9600CARESTREAM DENTAL LLCOAS2026-05-15
60192155951244CS 9600CARESTREAM DENTAL LLCOAS2026-05-15
E27668234830Primevision 3DSIRONA Dental Systems GmbHOAS2026-04-30
D804W1203005DRT0X-MIND optima 3DDE GÖTZEN SRLOAS2026-03-23
D804W1203005FLDRT0X-MIND optima 3DDE GÖTZEN SRLOAS2026-03-23
D804W1203010DRT0X-MIND optima 3DDE GÖTZEN SRLOAS2026-03-23
D804W1203015DRT0X-MIND optima 3DDE GÖTZEN SRLOAS2026-03-23
D804W1203015FLDRT0X-MIND optima 3DDE GÖTZEN SRLOAS2026-03-23
D804W1203020DRT0X-MIND optima 3DDE GÖTZEN SRLOAS2026-03-23
08033837934981myrayCEFLA SOCIETA' COOPERATIVAOAS2026-03-13
08033837935001myrayCEFLA SOCIETA' COOPERATIVAOAS2026-03-13
08033837936091NewTomCEFLA SOCIETA' COOPERATIVAOAS2026-03-13
08033837936107NewTomCEFLA SOCIETA' COOPERATIVAOAS2026-03-13
08033837936176CastelliniCEFLA SOCIETA' COOPERATIVAOAS2026-03-13
08033837936411CastelliniCEFLA SOCIETA' COOPERATIVAOAS2026-03-13
E27668234260Primevision 3DSIRONA Dental Systems GmbHOAS2026-02-13
00990010312418DURAYBeyes Dental Canada IncOAS2025-12-15
00990010312562DURAYBeyes Dental Canada IncOAS2025-12-15
00990010312579DURAYBeyes Dental Canada IncOAS2025-12-15
00990010312586DURAYBeyes Dental Canada IncOAS2025-12-15
00990010312593DURAYBeyes Dental Canada IncOAS2025-12-15
00990010312609DURAYBeyes Dental Canada IncOAS2025-12-15
08800003027026RAYSCANRay Co., LtdOAS2025-12-01
08809244060335GenorayGENORAY CO., LTD.OAS2025-12-01
08809244060472GenorayGENORAY CO., LTD.OAS2025-12-01
06974566270167FUSSENFussen Technology Co., Ltd.OAS2025-11-24
06974566270181FUSSENFussen Technology Co., Ltd.OAS2025-11-24
06974566271133FUSSENFussen Technology Co., Ltd.OAS2025-11-24