Philips

Primary DI
08436046002357
Brand
Philips
Company
SEDECAL
Model
MobileDiagnost wDR 2.2
Device description
Intended for use by a qualified/trained doctor or technologist on both adult and pediatric patients for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, and other body parts. Applications can be performed with patient sitting, standing or lying in the prone or supine positions. Not for mammography
Published
2019-08-09
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
IZLSystem, X-Ray, Mobile
MQBSolid State X-Ray Imager (Flat Panel/Digital Imager)

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
IZLSystem, X-Ray, MobileRadiology2
MQBSolid State X-Ray Imager (Flat Panel/Digital Imager)Radiology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
08436046002357PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
08436046002357084360460023578436046002357

GMDN Terms#

Term, Definition table
TermDefinition
Mobile basic diagnostic x-ray system, digitalAn assembly of devices that comprise a digital general-purpose mobile diagnostic x-ray system used in a variety of routine planar x-ray imaging applications. It uses digital techniques for image capture, display and manipulation and the mobile design allows it to operate on mains or battery power and to be driven or pushed by an operator to various locations within a building or facility. It is commonly used for bedside imaging and for interventional and intraoperative imaging. It consists of basic modular configurations that can be upgraded. This GMDN code does not cover systems with fluoroscopic or tomographic capabilities.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure700 millibar1060 millibar
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius35 Degrees Celsius
Storage Environment Atmospheric Pressure700 millibar1060 millibar
Storage Environment Humidity20 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius40 Degrees Celsius

Regulatory Flags#

DUNS number
510948979
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08436046003651SEDECALODYSSEY24202025-03-21
08436046003668SEDECALODYSSEY24322025-03-21
08436046003675SEDECALODYSSEY24402025-03-21
08436046003682SEDECALODYSSEY24502025-03-21
08436046003699SEDECALODYSSEY+24202025-03-21
08436046003705SEDECALODYSSEY+24322025-03-21
08436046003712SEDECALODYSSEY+24402025-03-21
08436046003729SEDECALODYSSEY+24502025-03-21
08436046001404SEDECALHERCULES-322016-10-31
08436046001411SEDECALHERCULES-402016-10-31
08436046001428SEDECALHERCULES-502016-10-31
08436046001435SEDECALHERCULES-652016-10-31
08436046001442SEDECALHERCULES-802016-10-31
08436046001572SEDECALSM-20HF-B-D-T2016-10-28
08436046001589SEDECALSM-32HF-B-D-T2016-10-28
08436046001596SEDECALSM-40HF-B-D-T2016-10-28
08436046001602SEDECALSM-50HF-B-D-T2016-10-28
08436046002166SEDECALSM-40HF-B-D-VIR2016-10-31
08436046002173SEDECALMobileDiagnost wDR2016-10-31
08436046002296SEDECALProteus XR/f ST2017-02-15

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00854810007007AirDRIcRco, Inc.MQB2026-07-22
00854810007014AirDRIcRco, Inc.MQB2026-07-22
00854810007120iDRIcRco, Inc.MQB2026-07-22
00854810007205AirDRIcRco, Inc.MQB2026-07-22
08809394330906VIVIX-S 4386WVIEWORKS CO., LTD.MQB2026-07-16
06938396401528SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401528SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401559SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401559SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401566SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401566SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401597SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401597SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401603SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401603SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401634SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401634SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401658SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401658SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401702SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401702SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396401719SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396401719SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
06938396410124SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.MQB2026-07-10
06938396410124SIUIShantou Institute of Ultrasonic Instruments Co., Ltd.IZL2026-07-10
08057737122040Villa Sistemi MedicaliVILLA SISTEMI MEDICALI SPAMQB2026-06-04
08057737122057Villa Sistemi MedicaliVILLA SISTEMI MEDICALI SPAMQB2026-06-04
08800011150129DRGEMDRGEM CorporationMQB2026-05-20
08800011150129DRGEMDRGEM CorporationIZL2026-05-20
08800011150136DRGEMDRGEM CorporationMQB2026-05-20