Nuubo System

Primary DI
08437011759078
Brand
Nuubo System
Company
SMART SOLUTIONS TECHNOLOGIES SL
Model
2140
Catalog number
2140
Device description
NuuboREC Box USA. Ambulatory ECG monitoring device (Holter) up to 30 days.
Published
2019-11-19
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
OTC
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DSHRECORDER, MAGNETIC TAPE, MEDICAL

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DSHRecorder, Magnetic Tape, MedicalCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K173461000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K173461000ECG recorder and Arrhythmia DetectorSmart Solutions Technologies SL2018-08-03DSH

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
08437011759078PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
08437011759078084370117590788437011759078

GMDN Terms#

Term, Definition table
TermDefinition
Electrocardiographic ambulatory recorderAn electrically-powered, noninvasive device designed to be worn by a patient during daily activities for 24-hour recording of the electrocardiographic signals of the heart, for the diagnosis of cardiac disorders (e.g., arrhythmias). The recorded measurements can be downloaded and analysed at a medical facility, typically using a computer with a dedicated software. Otherwise known as a Holter monitor, the device typically incorporates display and controls, and may include surface electrodes, lead wires and accessories intended for attachment/removal (e.g., wipes, adhesive remover).

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius45 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+34678078697pserna@nuubo.com

Regulatory Flags#

DUNS number
475359621
Device count
1
Combination product
true
Lot or batch
true
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08437011759016Nuubo System202020202019-11-15
08437011759023Nuubo System202120212019-11-15
08437011759030Nuubo System202220222019-11-15
08437011759092Nuubo System193519352019-11-20

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08883000007413AeviceMDAEVICE HEALTH PTE. LTD.DSH2026-05-18
00857522005125myPatch®DMS-SERVICE LLCDSH2026-05-06
00884838129238Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2026-04-17
00884838129245Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2026-04-17
K00010eWave 6-Lead EKGWearlinq, Inc.DSH2026-04-02
P00010eWave Electrode PatchWearlinq, Inc.DSH2026-04-02
00884838129214Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2026-03-09
00884838129221Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2026-03-09
17540279200027CardioSTATIcentia Inc.DSH2025-12-08
00884838127456Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2025-11-17
00884838127463Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2025-11-17
08800069700260AT-PatchATsens Co., Ltd.DSH2025-11-05
08800069700277AT-PatchATsens Co., Ltd.DSH2025-11-05
00884838127432Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2025-05-06
00884838127449Care AssistPhilips Medizin Systeme Böblingen GmbHDSH2025-05-06
27540279250029CardioSTATIcentia Inc.DSH2024-12-18
27540279250074CardioSTATIcentia Inc.DSH2024-12-18
27540279250142CardioSTATIcentia Inc.DSH2024-12-18
00884838123717Care AssistPhilips Medical Systems HsgDSH2024-11-27
00884838123724Care AssistPhilips Medical Systems HsgDSH2024-11-27
00860007323409Vitals360Vocare, Inc.DSH2024-09-10
B146EP25R0ePatch Sensor 2.5, RebuiltBRAEMAR MANUFACTURING, LLCDSH2024-06-26
04250413405640ABPM pro basic deviceSOMNOmedics AGDSH2024-05-08
00815187020112Matrix WearableGLOBAL INSTRUMENTATION, LLCDSH2024-04-01
00815187020440Matrix WearableGLOBAL INSTRUMENTATION, LLCDSH2024-04-01
00815187020457Matrix WearableGLOBAL INSTRUMENTATION, LLCDSH2024-04-01
00815187020587Matrix WearableGLOBAL INSTRUMENTATION, LLCDSH2024-04-01
00815187020594Matrix WearableGLOBAL INSTRUMENTATION, LLCDSH2024-04-01
17540279105018EARTIcentia Inc.DSH2024-03-26
17540279200072CardioSTATIcentia Inc.DSH2024-03-26