Cassini Guidance System

Primary DI
08720892096401
Brand
Cassini Guidance System
Company
Cassini Technologies B.V.
Model
1.0.0
Device description
Cassini Guidance System provides guidance assistance to the surgeon during eye surgeries. The device displays real-time non-diagnostic video during eye surgery on a flat panel display device positioned for live visualization by the surgeon and surgical personnel in the operating room. The Cassini Guidance System provides graphical tools to the surgeon as desired during treatment by using pre-operative clinical data and surgeon-driven, onscreen templates and tools. The system utilizes surgeon confirmation at each step to plan and position guidance tools. The system neither performs any interpretations nor provides treatment recommendations.
Published
2023-05-08
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
NFGDevice, Communications, Images, Ophthalmic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
NFGDevice, Communications, Images, OphthalmicRadiology1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
08720892096401PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
08720892096401087208920964018720892096401

GMDN Terms#

Term, Definition table
TermDefinition
Multidisciplinary medical image management softwareA software application intended to be used to receive, collect, store, and display a broad range of medical imaging and/or video data, and to distribute the data within or between healthcare facilities to facilitate data analysis, organization, reporting, and sharing (e.g., teaching); it might be designed for holographic viewing of three-dimensional (3-D) images in conjunction with an appropriate headset or for real-time communication of diagnostic/surgical images, and might also enable the control of light settings of a device (e.g., microscope) for image acquisition.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius35 Degrees Celsius
Storage Environment Humidity30 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature10 Degrees Celsius55 Degrees Celsius

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
492566474
Device count
1
Premarket exempt
true
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08719326059600CASSINI2.0,3.02021-03-03

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00627987702149Optina FotysOptina Diagnostiques, IncNFG2025-08-29
04260284390013Navilas® Laser System 577sOD-OS GmbHNFG2023-11-21
04987669200636Image filing software NAVIS-EXNIDEK CO.,LTD.NFG2023-06-12
04549292182729CANON INC.CANON INC.NFG2020-10-16
00380659982682VERION™Alcon Laboratories, Inc.NFG2020-08-31
00380659982699VERION™Alcon Laboratories, Inc.NFG2020-08-31
00380659982705VERION™Alcon Laboratories, Inc.NFG2020-08-31
00380659982811VERION™Alcon Laboratories, Inc.NFG2020-08-31
04049471100020FORUM Viewer AppCarl Zeiss Meditec AGNFG2018-03-22
04987669100523Image filing softwareNIDEK CO.,LTD.NFG2016-08-26
04987669100554NON-MYDRIATIC AUTO FUNDUS CAMERANIDEK CO.,LTD.NFG2016-06-24
03596010589637INTEGRATION BROKERSmith & Nephew, Inc.NFG2016-04-12
03596010588371N/ASmith & Nephew, Inc.NFG2016-04-12
04049471094077VISUPAC 500Carl Zeiss Meditec AGNFG2016-01-15
03596010588388INTEGRATION BROKERSmith & Nephew, Inc.NFG2015-08-29