XTG

Primary DI
08800021800168
Brand
XTG
Company
DigiMed Co., Ltd.
Model
1
Catalog number
1
Device description
The device is an x-ray generating device which is mainly designed for dental examination. The device has an x-ray tube for generating x-rays, a high voltage transformer for generating high voltages, a high voltage rectification circuit for transforming and boosting AC voltage to mixed pulse voltage, a high voltage divide circuit for lowering high voltage to low voltage to measure and calibrate high voltages, as well as a high voltage tube tank, a high frequency inverter circuit for generating high voltages, a control P.C.B for controlling, saving and displaying the data, a power P.C.B for supplying power to the circuit and apparatus in housing, user interface (LCD screen) and beam limiting part (x-ray emitting cone). The apparatuses above can be embedded in one or several cases, and except for the radiation opening in the x-ray system, all units are completely shielded by lead or high-density materials, protecting patients and users from unnecessary exposure of radiation. The device is intended to be used by trained dentists and dental technicians as an extra-oral X-ray source producing diagnostic X-ray images using with intra-oral image receptors. Its use is intended for adults and pediatric subjects both.
Published
2026-06-01
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Product Codes#

Code, Name table
CodeName
EHDUnit, X-Ray, Extraoral With Timer

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
EHDUnit, X-Ray, Extraoral With TimerDental2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K181891000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K181891000Portable X-ray System (Model: MiniX-V, Mini X-S)Digimed Co., Ltd.2018-08-10EHD

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
18800021800165PackageGS11In Commercial Distribution
28800021800162PackageGS12In Commercial Distribution
38800021800169PackageGS13In Commercial Distribution
48800021800166PackageGS14In Commercial Distribution
58800021800163PackageGS15In Commercial Distribution
68800021800160PackageGS16In Commercial Distribution
78800021800167PackageGS17In Commercial Distribution
88800021800164PackageGS18In Commercial Distribution
08800021800168PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
1880002180016518800021800165
2880002180016228800021800162
3880002180016938800021800169
4880002180016648800021800166
5880002180016358800021800163
6880002180016068800021800160
7880002180016778800021800167
8880002180016488800021800164
08800021800168088000218001688800021800168

GMDN Terms#

Term, Definition table
TermDefinition
Hand-held intraoral dental x-ray system, digitalA diagnostic dental x-ray system designed to generate and control x-ray beams. It records the absorption pattern of x-ray beams used for general-purpose, routine, dental radiography examinations involving the diagnosis and treatment (e.g., surgical or interventional) of diseases of the teeth, jaw and oral cavity structures. It is designed to be easily carried from location to location by a single operator. The sensor is placed in the mouth, the purpose being to visualize a limited region in detail. The data is either from analogue imaging and digitized afterwards or by digital imaging.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure00
Handling Environment Humidity00
Handling Environment Temperature00
Storage Environment Atmospheric Pressure00
Storage Environment Humidity00
Storage Environment Temperature00

Regulatory Flags#

DUNS number
688265810
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
false
Serial number
true
Manufacturing date on label
true
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
false

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08800021800175XTG V112026-06-01
08800021800113xm-liteHYBRID C702022-12-01
08800021800045BIOX12024-06-12
08800021800106HYBRID S7012024-06-12
08800021800120XTG PRO 70HYBRID Pro2024-06-12
08800021800137DHX-70H12024-06-12
18800021800042BIOX12024-06-12
18800021800103HYBRID S7012024-06-12
18800021800127XTG PRO 70HYBRID Pro2024-06-12
18800021800134DHX-70H12024-06-12
08800021800007PROX1DPC-042016-11-07
78800021800006PROX1DPC-042016-11-07
08800021800014DIOX-6021DDC-032016-11-07
18800021800110xm-liteHYBRID C702022-12-01
08800021800021MiniX-S112018-01-19
08800021800038MiniX-V1DMC-072016-11-07
88800021800027MiniX-S112018-01-19
88800021800034MiniX-V1DMC-072016-11-07

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08800021800175XTG VDigiMed Co., Ltd.EHD2026-06-01
D090800047970NOMAD Pro 3 X-Ray Tubehead, USDental Imaging Technologies CorporationEHD2026-03-31
D090800048750NOMAD Pro 3 Packaged System, USDental Imaging Technologies CorporationEHD2026-03-31
D090800048870NOMAD Pro 3 Packaged System, US Dental Imaging Technologies CorporationEHD2026-03-31
08809840720046WeRayPICOPACK Inc.EHD2024-10-24
08800021800045BIOXDigiMed Co., Ltd.EHD2024-06-12
08800021800106HYBRID S70DigiMed Co., Ltd.EHD2024-06-12
08800021800120XTG PRO 70DigiMed Co., Ltd.EHD2024-06-12
08800021800137DHX-70HDigiMed Co., Ltd.EHD2024-06-12
07899581344695EVOLVE SENSORAlliage S/A Indústrias Médico OdontológicaEHD2023-12-08
07899581344701EVOLVE SENSORAlliage S/A Indústrias Médico OdontológicaEHD2023-12-08
07899581340253Intraoral Dental Digital Imaging SensorAlliage S/A Indústrias Médico OdontológicaEHD2023-10-18
07899581340260Intraoral Dental Digital Imaging SensorAlliage S/A Indústrias Médico OdontológicaEHD2023-10-18
07899581340284Intraoral Dental Digital Imaging SensorAlliage S/A Indústrias Médico OdontológicaEHD2023-10-18
07899581340697Intraoral Dental Digital Imaging SensorAlliage S/A Indústrias Médico OdontológicaEHD2023-10-18
07899581340727Intraoral Dental Digital Imaging SensorAlliage S/A Indústrias Médico OdontológicaEHD2023-10-18
08800021800113xm-liteDigiMed Co., Ltd.EHD2022-12-01
08800124900000CLAROXVSI Co., Ltd.EHD2022-07-25
08800072313211Portable Dental X-ray (CS 2400P)NANORAY CO.,LTDEHD2021-02-18
08800072313310Portable Dental X-ray (CS 2300P)NANORAY CO.,LTDEHD2021-02-18
08800072313419Portable Dental X-ray (NR-F350 with Back scatter shield)NANORAY CO.,LTDEHD2021-02-18
08800072313518Portable Dental X-ray (R2 Port-X without Back scatter shield)NANORAY CO.,LTDEHD2021-02-18
08800072313617Portable Dental X-ray (R2 Port-X with Back scatter shield)NANORAY CO.,LTDEHD2021-02-18
D7641000083061XIOS AESIRONA DENTAL, INC.EHD2019-06-06
D7641000081680XIOS AESIRONA DENTAL, INC.EHD2019-06-05
D7641000081790XIOS AESIRONA DENTAL, INC.EHD2019-06-05
D7641000083480XIOS AESIRONA DENTAL, INC.EHD2019-06-05
08800040900047POSKOM Co., Ltd.Poskom Co., Ltd.EHD2018-06-19
D7641000064510Intraoral Sensor WallboxSIRONA DENTAL, INC.EHD2018-05-10
D7641000064561Intraoral Sensor WallboxSIRONA DENTAL, INC.EHD2018-05-10