VVR Generator

GUDID 08809306769244

VVR Generator System consists of Generator (VVR Generator), Active electrode (VENISTAR) and accessory such as foot switch and cooling pump. The generator generates, controls and monitors RF energy and delivers energy to the active electrode. The active electrode has an active coil and a receiver coil that allow the RF energy to flow through the tissue. The RF energy raises the temperature in the tissue, causing coagulation and occlusion of blood vessels. The single footswitch works as an on/off switch and the double footswitch works to increase or decrease the power output. A cooling pump circulates water around the electrodes to reduce the temperature of the electrodes and prevent tissue sticking to the electrodes.

STARMED CO.,LTD

Percutaneous radio-frequency ablation system generator
Primary Device ID08809306769244
NIH Device Record Key7a308313-6470-4212-b184-e3c87669fba5
Commercial Distribution StatusIn Commercial Distribution
Brand NameVVR Generator
Version Model NumberVVR10
Company DUNS694699723
Company NameSTARMED CO.,LTD
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usefalse
Lot Batchfalse
Serial Numbertrue
Manufacturing Datetrue
Expiration Datefalse
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Device Identifiers

Device Issuing AgencyDevice ID
GS108809306769244 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

GEIElectrosurgical, Cutting & Coagulation & Accessories

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusNew
Device Record StatusPublished
Public Version Number1
Public Version Date2024-10-08
Device Publish Date2024-09-30

Devices Manufactured by STARMED CO.,LTD

08809306769244 - VVR Generator2024-10-08VVR Generator System consists of Generator (VVR Generator), Active electrode (VENISTAR) and accessory such as foot switch and cooling pump. The generator generates, controls and monitors RF energy and delivers energy to the active electrode. The active electrode has an active coil and a receiver coil that allow the RF energy to flow through the tissue. The RF energy raises the temperature in the tissue, causing coagulation and occlusion of blood vessels. The single footswitch works as an on/off switch and the double footswitch works to increase or decrease the power output. A cooling pump circulates water around the electrodes to reduce the temperature of the electrodes and prevent tissue sticking to the electrodes.
08809306769244 - VVR Generator2024-10-08 VVR Generator System consists of Generator (VVR Generator), Active electrode (VENISTAR) and accessory such as foot switch and co
18809306764017 - VENISTAR2024-09-06
18809306764871 - VENISTAR2024-09-06
18809306767865 - VENISTAR2024-09-06
18809306767872 - VENISTAR2024-09-06
18809922260634 - ELRA Electrode2024-09-05
08809922260620 - ELRA Electrode2023-12-04
08809922260644 - ELRA Electrode2023-12-04

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.