Optimos™ Cystotome

Primary DI
08809909406416
Brand
Optimos™ Cystotome
Company
TAEWOONGMEDICAL.CO.,LTD
Model
OCT1907
Catalog number
OCT1907
Device description
The Optimos™ Cystotome is intended for use as an electrosurgical accessory to cannulate the transgastric or transduodenal wall and into a pancreatic pseudocyst that is visibly bulging into the gastrointestinal tract. This device is supplied sterile and is intended for single use only.
Published
2023-04-18
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
KNSUnit, Electrosurgical, Endoscopic (With Or Without Accessories)

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
KNSUnit, Electrosurgical, Endoscopic (With Or Without Accessories)Gastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K223256000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K223256000Optimos™ CystotomeTaewoong Medical Co., Ltd.2023-04-05KNS

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
08809909406416PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
08809909406416088099094064168809909406416

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic electrosurgical electrode, monopolar, single-useA sterile, invasive, distal component of an electrosurgical assembly intended to deliver electrosurgical current in a monopolar configuration (i.e., used with a patient contact return electrode) to tissues for cutting/coagulation/ablation during endoscopic (e.g., laparoscopic, arthroscopic) surgery. It is available in a variety of forms (e.g., exchangeable electrode for electrosurgical forceps, rigid electrode, flexible endoscopic probe) which may include a lumen for suction/irrigation. It does not include a handpiece or housing and has no electrical or mechanical controls (e.g., does not include ring-handles); it is not intended for gas-enhanced electrosurgery. This is a single-use device.

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
323-692-0028minsoo@taewoongusa.com
+82319960641contact@stent.net

Regulatory Flags#

DUNS number
689484322
Device count
1
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08809909424502SphincterotomeOST0720OST07202026-05-29
08809909424519SphincterotomeOST0725OST07252026-05-29
08809909424526SphincterotomeOST0730OST07302026-05-29
08809909424533SphincterotomeOST0720SOST0720S2026-05-29
08809909424540SphincterotomeOST0725SOST0725S2026-05-29
08809909424557SphincterotomeOST0730SOST0730S2026-05-29
08809909421457SnareKSN22FHC-10KSN22FHC-102026-04-27
08809909421464SnareKSN22FHC-15KSN22FHC-152026-04-27
08809909421471SnareKSN22FHC-20KSN22FHC-202026-04-27
08809909421488SnareKSN22FYC-20KSN22FYC-202026-04-27
08809909421709CystotomeOCT1907OCT19072026-04-27
08809909421716CystotomeOCT1908OCT19082026-04-27
08809909421723Biopsy ForcepsJBFR160JBFR1602026-04-27
08809909421730Biopsy ForcepsJBFR160CJBFR160C2026-04-27
08809909421747Biopsy ForcepsBF160BF1602026-04-27
08809909421754Biopsy ForcepsBF160NBF160N2026-04-27
08809909421761Biopsy ForcepsBF160CBF160C2026-04-27
08809909421778Biopsy ForcepsBFR160BFR1602026-04-27
08809909421785Biopsy ForcepsBFR160NBFR160N2026-04-27
08809909421792Biopsy ForcepsBFR160CBFR160C2026-04-27

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
06959664901069NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664901076NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664901595NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664901663NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664901687NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664901700NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664901717NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664902646NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664903520NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664910498NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664910559NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664910566NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664910597NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664910764NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664911921NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664911976NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664911983NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664911990NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912041NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912065NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912072NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912089NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912096NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912102NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664912119NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664919118NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664934036NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664934067NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664934074NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17
06959664934098NAHangzhou AGS MedTech Co., Ltd.KNS2026-07-17