R2*/T2* Phantom

Primary DI
09355529000088
Brand
R2*/T2* Phantom
Company
RESONANCE HEALTH ANALYSIS SERVICES PTY LTD
Model
v1.0
Catalog number
-
Device description
The R2*/T2* phantom is a medical device accessory intended to be used as an alternative to human test subject to avoid potential complications for an MRI centre in order to evaluate that the scanning protocol have been correctly set up for the analysis of cardiac R2* and T2* values using the CardiacT2* on 1.5T and 3T MRI scanners. The R2*/T2* Phantom consists of an amber bottle having 09 (nine) plastic tubes (30mL) of 0.8% Agarose (C24H38O19) gel doped with varying known concentrations (0.10 mM to 3.2 mM) of manganese chloride (MnCl2).
Published
2024-04-17
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
IXGPhantom, Anthropomorphic, Radiographic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
IXGPhantom, Anthropomorphic, RadiographicRadiology1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
09355529000088PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
09355529000088093555290000889355529000088

GMDN Terms#

Term, Definition table
TermDefinition
MRI phantom, test objectA device that consists of a uniform density, or a two or three-dimensional (3-D) pattern of objects, materials or openings of varying dimensions and material densities. It is available in both fixed and variable configurations and is a quality assurance (QA) device used in both subjective and quantitative evaluations of various calibration and performance characteristics of magnetic resonance imaging (MRI) systems or magnetic resonance spectroscopy systems and associated image acquisition, display, and analysis computer programs.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Temperature13 Degrees Celsius40 Degrees Celsius
Storage Environment Temperature13 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+61892865300quality@resonancehealth.com

Regulatory Flags#

DUNS number
740449913
Device count
1
Premarket exempt
true
Lot or batch
true
Serial number
true
Expiration date on label
true
Donation ID number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
09369998038619FerriSmartv012024-06-07
09355529000019HepaFat-AIV1.0.02024-06-07
09355529000057FerriSmartv2.2.4-2024-06-06
09355529000095HepaFatSmartv2.0.0-2024-04-29
09355529000033T1CMR Phantom (1.5T)v1.0-2024-04-17
09355529000064T1CMR Phantom (3.0T)v1.0-2024-04-17
09355529000071T2CMR Phantomv1.0-2024-04-17
09355529000026FerriScan Phantomv1.0 (15 vials (0 to 3.2 mM))2016-11-10
09355529000002FerriScan, Cardiac T2*4.0.02023-06-19
09355529000040HepaFat-ScanV1.1.02023-06-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00812266030932Rando®Providus Holdings, Inc.IXG2024-07-11
00812266030949Rando®Providus Holdings, Inc.IXG2024-07-11
00812266030956Rando®Providus Holdings, Inc.IXG2024-07-11
00812266030963Rando®Providus Holdings, Inc.IXG2024-07-11
00812266030970Rando®Providus Holdings, Inc.IXG2024-07-11
00812266030987Rando®Providus Holdings, Inc.IXG2024-07-11
00812266030994Rando®Providus Holdings, Inc.IXG2024-07-11
00812266031007Rando®Providus Holdings, Inc.IXG2024-07-11
06977071930908MeicenGuangdong Meicen Medical Equipment Co., Ltd.IXG2024-06-21
00812266030758LiquiPhil™Providus Holdings, Inc.IXG2024-05-07
00812266030765LiquiPhil™Providus Holdings, Inc.IXG2024-05-07
00812266030772LiquiPhil™Providus Holdings, Inc.IXG2024-05-07
00812266030789LiquiPhil™Providus Holdings, Inc.IXG2024-05-07
00812266030796LiquiPhil™Providus Holdings, Inc.IXG2024-05-07
00812266030802LiquiPhil™Providus Holdings, Inc.IXG2024-05-07
00812266030697LiquiPhil™Providus Holdings, Inc.IXG2024-05-03
00812266030703LiquiPhil™Providus Holdings, Inc.IXG2024-05-03
00812266030710LiquiPhil™Providus Holdings, Inc.IXG2024-05-03
00812266030727LiquiPhil™Providus Holdings, Inc.IXG2024-05-03
00812266030734LiquiPhil™Providus Holdings, Inc.IXG2024-05-03
00812266030741LiquiPhil™Providus Holdings, Inc.IXG2024-05-03
09355529000033T1CMR Phantom (1.5T)RESONANCE HEALTH ANALYSIS SERVICES PTY LTDIXG2024-04-17
09355529000064T1CMR Phantom (3.0T)RESONANCE HEALTH ANALYSIS SERVICES PTY LTDIXG2024-04-17
09355529000071T2CMR PhantomRESONANCE HEALTH ANALYSIS SERVICES PTY LTDIXG2024-04-17
00812266030673LiquiPhil™Providus Holdings, Inc.IXG2024-03-18
00812266030680LiquiPhil™Providus Holdings, Inc.IXG2024-03-18
EIBASR020010myQA® SRS Phantom CyberknifeIBA Dosimetry GmbHIXG2023-10-10
00850019946505Standard Imaging Lucy 3D QA PhantomSTANDARD IMAGING INC.IXG2023-06-22
00850019946512Standard Imaging MIMI PhantomSTANDARD IMAGING INC.IXG2023-06-22
00850019946529Standard Imaging Stereotactic Dose Verification PhantomSTANDARD IMAGING INC.IXG2023-06-22