i-STAT TBI cartridge

Primary DI
10054749005779
Brand
i-STAT TBI cartridge
Company
Abbott Point of Care Inc.
Model
03S09-25
Catalog number
03S09-25
Device description
i-STAT TBI cartridge
Published
2024-07-08
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
QATBrain trauma assessment test

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
QATBrain Trauma Assessment TestImmunology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K234143000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K234143000i-STAT TBI Cartridge with the i-STAT Alinity SystemAbbott Point of Care2024-03-27QAT

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00054749005772PackageGS125In Commercial Distribution
10054749005779PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00054749005772000547490057720547490057720054749005772
1005474900577910054749005779

GMDN Terms#

Term, Definition table
TermDefinition
Multiple traumatic brain injury marker IVD, kit, rapid non-ICT electrochemical immunoassay, clinicalA collection of reagents and other associated materials intended to be used for the qualitative and/or (semi-)quantitative detection of multiple biochemical markers associated with traumatic brain injury in a clinical specimen within a short period, relative to standard laboratory testing procedures, using a rapid electrochemical immunoassay method [excludes immunochromatographic tests (ICT)]. This test is commonly used in the laboratory or in point-of-care analyses to detect glial fibrillary acidic protein (GFAP) and ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) as an aid to determine the need for a neuroimaging scan following head injury. It is not intended to be used for self-testing.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Temperature2 Degrees Celsius8 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
+1(800)366-8020techsvc@apoc.abbott.com

Regulatory Flags#

DUNS number
116279183
Device count
1
Lot or batch
true
Expiration date on label
true
Contains natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10054749005519i-STAT09P31-2609P31-262020-05-01
10054749000163i-STAT03P88-2503P88-252016-09-09
10054749000132i-STAT03P85-2503P85-252016-09-09
00054749004027i-STAT06F24-2006F24-202023-09-22
00054749001385i-STAT06F24-1606F24-162023-06-23
00054749004911i-STAT hs-TnI Calibration Verification, Levels 1-306P17-2006P17-202025-05-02
00054749004928i-STAT hs-TnI Control Level 106P17-2106P17-212025-05-02
00054749004935i-STAT hs-TnI Control Level 206P17-2206P17-222025-05-02
00054749004942i-STAT hs-TnI Control Level 306P17-2306P17-232025-05-02
10054749003058i-STAT hs-TnI cartridge09P81-2509P81-252025-04-29
00054749003051i-STAT hs-TnI cartridge09P81-2509P81-252025-04-29
00054749005772i-STAT TBI cartridge03S09-2503S09-252024-07-08
00054749000661i-STAT06F14-0106F14-012023-06-23
10054749000071i-STAT03P79-2503P79-252016-09-09
10054749000149i-STAT03P86-2503P86-252016-09-09
10054749000170i-STAT03P89-2403P89-242016-09-09
10054749000187i-STAT03P90-2503P90-252016-09-09
10054749000200i-STAT03P92-2503P92-252016-09-09
10054749000217i-STAT03P93-2503P93-252016-09-09
10054749000118i-STAT03P83-2503P83-252016-09-09

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
03573026626891VIDASĀ® TBI (GFAP, UCH-L1)BIOMERIEUX SAQAT2024-10-31
00054749005772i-STAT TBI cartridgeAbbott Point of Care Inc.QAT2024-07-08
00380740213947ARCHITECTAbbott Ireland DiagnosticsQAT2024-03-15
00380740213954ARCHITECTAbbott Ireland DiagnosticsQAT2024-03-15
00380740209469AlinityAbbott Ireland DiagnosticsQAT2023-07-11
00380740209490AlinityAbbott Ireland DiagnosticsQAT2023-07-11
10054749005069i-STATABBOTT POINT OF CARE INC.QAT2021-10-12
00054749005611i-STATABBOTT POINT OF CARE INC.QAT2021-10-12
00054749005062i-STATABBOTT POINT OF CARE INC.QAT2021-10-12