microTargeting™ Electrode and Insertion Tube Kit

Primary DI
10873263008918
Brand
microTargeting™ Electrode and Insertion Tube Kit
Company
FHC, INC.
Model
KTF1002-00891
Catalog number
KTF1002
Device description
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) - 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) - 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) - 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
Published
2025-04-30
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GZLELECTRODE, DEPTH
HAOINSTRUMENT, SURGICAL, NON-POWERED
HAWNeurological stereotaxic Instrument

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GZLElectrode, DepthNeurology2
HAOInstrument, Surgical, Non-PoweredNeurology1
HAWNeurological Stereotaxic InstrumentNeurology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10873263008918PrimaryGS10
00873263008911Unit of UseGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
1087326300891810873263008918
00873263008911008732630089118732630089110873263008911

GMDN Terms#

Term, Definition table
TermDefinition
Intracerebral cannula, nonimplantable, single-useA sterile, nonimplantable, rigid tube intended to be surgically inserted through the skull to access the brain (e.g., cerebral ventricles) for cerebrospinal fluid (CSF) drainage, infusion of materials, and/or for use as a port through which instruments, leads and/or probes can be passed to perform a variety of diagnostic, treatment, or surgical procedures. It is usually made of metal (e.g., stainless steel) and may include a stylet/trocar blade. This is a single-use device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity0 Degrees Celsius95 Degrees Celsius
Storage Environment Humidity0 Degrees Celsius95 Degrees Celsius
Storage Environment Temperature0 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method
Ethylene Oxide

Contacts#

Phone, Email table
PhoneEmail
+1(800)326-2905fhcinc@fh-co.com

Regulatory Flags#

DUNS number
108179458
Device count
5
Lot or batch
true
Manufacturing date on label
true
Expiration date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00873263007693microTargeting™ Insertion Tube66-IT-IT2P-0076966-IT-IT2P2026-05-08
00873263007785microTargeting™ Insertion Tube66-IT(IT2)-0077866-IT(IT2)2026-05-08
00873263007792microTargeting™ Insertion Tube66-PT(IT2)-0077966-PT(IT2)2026-05-08
00873263003046WayPoint™ Surgical Kit66-WP-SKS-0030466-WP-SKS2016-09-17
00873263003190WayPoint™ Implant Kit66-WP-IKS-0031966-WP-IKS2016-09-17
00873263009604microTargeting™ Measurement Probe66-MO-31-0096066-MO-312026-03-16
00873263009468microTargeting™ PlatformMP-KIT-P-VO-00946MP-KIT-P-VO2026-03-16
00873263009475microTargeting™ Measurement Probe66-MO-31-0096066-MO-312026-03-16
10873263009625microTargeting™ ElectrodeMTDWLN(BP)(BP11)-00962MTDWLN(BP)(BP11)2026-03-12
00873263009611microTargeting™ ElectrodeMTDWLP(BP)(BP11)-00961MTDWLP(BP)(BP11)2026-03-12
10873263009618microTargeting™ ElectrodeMTDWLP(BP)(BP11)-00961MTDWLP(BP)(BP11)2026-03-12
00873263009628microTargeting™ ElectrodeMTDWLN(BP)(BP11)-00962MTDWLN(BP)(BP11)2026-03-12
00873263002254STar™ Drive XL Frame Adapter70-FA-RD-XL-0022570-FA-RD-XL2016-09-17
00873263002285STar™ Drive XL Frame Adapter70-FA-LX-XL-0022870-FA-LX-XL2016-09-17
00873263002322STar™ Drive Frame Adapter70-FA-LX-0023270-FA-LX2016-09-17
00873263002360microTargeting™ STar™ Array Insertion Tube Extractor70-CN-ET-0023670-CN-ET2016-09-17
00873263006047WayPoint™ Entry Offset Mounting Hub66-MP-EH-0060466-MP-EH2018-04-01
00873263006184STar™ Drive Frame Adapter70-FA-GP-0061870-FA-GP2017-08-29
00873263008546STar™ Drive Frame Adapter70-FA-LX-NN-0085470-FA-LX-NN2022-09-26
00873263009581STar™ Drive Frame Adapter70-FA-LS-0095870-FA-LS2026-01-25

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08720892330826Ball Joint Guide Array (BJGA)-Navigation SetBayer Medical Care B.V.HAW2026-04-24
08720892330833Ball Joint Guide Array (BJGA)-Guide SetBayer Medical Care B.V.HAW2026-04-24
G586N93065370Novo SurgicalNOVO SURGICAL, INC.HAO2024-02-22
G586N93065380Novo SurgicalNOVO SURGICAL, INC.HAO2024-02-22
G076A012354A1Localite TMS Navigator TSLOCALITE GmbHHAW2023-07-05
G076A012355A1Localite TMS Navigator TSLOCALITE GmbHHAW2023-07-05
07613327499711N/AStryker Leibinger GmbH & Co. KGHAW2023-03-23
07613327500516N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
07613327500561N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
07613327500578N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
07613327503265N/AStryker Leibinger GmbH & Co. KGHAW2022-07-22
G28435301ScrewdriverNeurovention LLCHAO2022-06-21
07613327262322XIAStryker CorporationHAO2019-11-21
07613327264432XIA 4.5Stryker CorporationHAO2019-11-21
07613327264951XIA 3Stryker CorporationHAO2019-11-21
07613327271447OASYSStryker CorporationHAO2019-11-21
07613327276176RADIUSStryker CorporationHAO2019-11-21
07613327263787RELIANCE LITeStryker CorporationHAO2019-11-20
07613327263923RELIANCE LITeStryker CorporationHAO2019-11-20
07613327265897RELIANCE LITeStryker CorporationHAO2019-11-20
07613327265910RELIANCE LITeStryker CorporationHAO2019-11-20
07613327265934RELIANCE LITeStryker CorporationHAO2019-11-20
07613327266016RELIANCE LITeStryker CorporationHAO2019-11-20
10381780167778Integra® Ruggles®-Redmond™INTEGRA LIFESCIENCES PRODUCTION CORPORATIONHAO2018-10-23
10381780222682Integra® Ruggles®-Redmond™INTEGRA LIFESCIENCES PRODUCTION CORPORATIONHAO2018-09-12
10381780223276Integra® Ruggles®-Redmond™INTEGRA LIFESCIENCES PRODUCTION CORPORATIONHAO2018-09-12
10381780223283Integra® Ruggles®-Redmond™INTEGRA LIFESCIENCES PRODUCTION CORPORATIONHAO2018-09-12
10381780223368Integra® Ruggles®-Redmond™INTEGRA LIFESCIENCES PRODUCTION CORPORATIONHAO2018-09-12
07613327413076n/aStryker Leibinger GmbH & Co. KGHAW2018-08-08
07613327413090n/aStryker Leibinger GmbH & Co. KGHAW2018-08-08