Puritan Bennett

Primary DI
10884521139855
Brand
Puritan Bennett
Company
Covidien LP
Model
10005002
Device description
Neonatal Flow and CO2 Sensor Disposable;For 980 Series Ventilator
Published
2021-04-15
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
BXPTRANSDUCER, GAS FLOW

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
BXPTransducer, Gas FlowAnesthesiology1

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10884521139855PackageGS110In Commercial Distribution
20884521139852PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088452113985510884521139855
2088452113985220884521139852

GMDN Terms#

Term, Definition table
TermDefinition
Carbon dioxide cuvette, single-useA device intended to be used with a mainstream carbon dioxide (CO2) sensor for the determination of CO2 concentration in gases expired from a patient. It is designed as a small, plastic, open-ended vessel with a clear optic window (cuvette) for the acceptance of an infrared sensor that is slotted over the outside of the window section. It typically has connector ports that enable it to be connected into a breathing system (e.g., an anaesthesia or critical care ventilation system). This is a single-use device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Keep dry
Storage Environment Temperature-40 Degrees Fahrenheit158 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
1
DM exempt
false
Premarket exempt
true
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
false
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
true
Sterilization required before use
false

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521845985INVOSPMC71VP-GE2025-07-03
10884521063150ILA3948L2015-08-28
10884521102422Steel88862345-532015-08-31
10884521103863TaperGuard18780S2016-09-24
10884521211933Shiley5-182372017-05-10
10884521543799SigniaSIGPSHELL2017-08-08
10884521713208EdgeE1455B2016-11-18
10884521713277EdgeE1475X2016-11-18
20884521103631Mallinckrodt5-182372015-08-28
20884521105574Mallinckrodt5-185412015-08-28
40884521105578Shiley5-185412018-05-16
10884521543881SigniaSIGMRET2017-07-24
10884521543874SigniaSIGRIG2017-07-31
10884521620254Shiley862342016-09-24
10884521543812SigniaSIGADAPTXL2017-08-08
10884521101098NellcorMAXPACAI2016-09-24
10884521543782SigniaSIGPHANDLE2017-08-08
10884521543867SigniaSIGSBCHGR2017-08-01
10884521128927SonicisionSCST2016-09-24
10884521543829SigniaSIGADAPTSHORT2017-09-12

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00884838105584Flow SensorRespironics Novametrix, LLCBXP2023-11-15
00884838105607Flow SensorRespironics Novametrix, LLCBXP2023-11-15
30884838105585RespironicsRespironics Novametrix, LLCBXP2023-11-15
30884838105608RespironicsRespironics Novametrix, LLCBXP2023-11-15
07640142190479Spiro-SP TrueFlow SensorNDD Medizintechnik AGBXP2023-06-23
20884521210933Puritan BennettCovidien LPBXP2023-02-03
10884521210936Puritan BennettCovidien LPBXP2023-02-03
04048675000099Neonatal flow sensor ISO15Drägerwerk AG & Co. KGaABXP2022-04-08
04048675005612SpiroLifeDrägerwerk AG & Co. KGaABXP2022-04-08
04048675448853Neonatal flow sensor insertDrägerwerk AG & Co. KGaABXP2022-04-08
04048675448860Spirolog Flow SensorDrägerwerk AG & Co. KGaABXP2022-04-08
04048675448938Infinity ID Flow SensorDrägerwerk AG & Co. KGaABXP2022-04-08
20884521139852Puritan BennettCovidien LPBXP2021-04-15
00884838014114Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014121Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014138Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014145Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014152Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014350Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014367Flow SensorRespironics Novametrix, LLCBXP2020-09-14
00884838014374Flow SensorRespironics Novametrix, LLCBXP2020-09-14
06944904096766Respiratory Mech mod,w/accssryShenzhen Mindray Bio-Medical Electronics Co., Ltd.BXP2020-05-07
06420099000554M9256, SpiroSafe Disposable Flow TransducerMedikro OyBXP2018-07-13
06420099000561M9256, SpiroSafe Disposable Flow TransducerMedikro OyBXP2018-07-13
04036616001809Flow sensorHoneywell Healthcare Solutions GmbHBXP2016-09-22
04049098007740Respiratory Mechanics Flow Sensor – Adult/PediatricDRAEGER MEDICAL SYSTEMS, INC.BXP2015-11-02