Mon-a-Therm

Primary DI
10884521169302
Brand
Mon-a-Therm
Company
Covidien LP
Model
502-0410A
Device description
Cable 400TM;For use with 4070 Temperature Monitor
Published
2019-02-21
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FLLThermometer, electronic, clinical

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FLLContinuous Measurement ThermometerGeneral Hospital2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K895875000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K895875000MODEL 4070 TEMPERATURE MONITORMallinckrodt Anesthesia Products1989-12-21FLL

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10884521706422PackageGS140In Commercial Distribution
10884521169302PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088452170642210884521706422
1088452116930210884521169302

GMDN Terms#

Term, Definition table
TermDefinition
Electrical-only medical device connection cable, reusableA non-patient-contact, insulated, electrical cord with a connector (plug) at both ends designed to transmit electrical power and/or signal (data) between medical devices (e.g., to connect a lead, electrical catheter, handpiece, or monitor to a parent device). It is not intended to connect directly to patient-worn electrodes (i.e., it is not a lead), is not intended to connect to the mains (i.e., not a mains power cable), does not generate any type of power and/or signal, and has no additional non-electrical conducting or processing functionality. This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length10Feet

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity15 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature-40 Degrees Celsius70 Degrees Celsius
Special Storage Condition, Specify00Protect from moisture
Storage Environment Humidity15 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-40 Degrees Celsius70 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
1
Lot or batch
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521705166SofsilkSS622G2017-06-27
10884521757714Maxon8886616523-22020-07-19
10884521099272Chemosite1200492015-10-22
10884521099289Chemosite1200892015-09-28
10884521099265Chemosite1200392015-10-22
10884521852273BIS AdvancePMC80CB2026-10-26
10884521783829LigaSureMRASILF192026-10-23
10884521853812Shiley1108602026-10-25
10884521853829Shiley1108652026-10-25
10884521853836Shiley1108702026-10-25
10884521853843Shiley1108752026-10-25
10884521853850Shiley1108802026-10-25
10884521853867Shiley1108852026-10-25
10884521853874Shiley1108902026-10-25
10884521856547Touch SurgeryMDS300282026-10-23
10884521861114Vital SyncVITALSYNCSW032026-10-25
10884521039902Surgipro llVPF-703-MX2015-09-02
10884521063433Ti-CronX-11362015-09-02
10884521073951Versaport PlusNB8STF2016-09-24
10884521195677Surgipro IIVP-653-MX2015-09-02

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00860016681507UNIVERHEALTHHangzhou Universal Electronic Co.,Ltd.FLL2026-10-28
09120095900809SteadyTempSteadySense GmbHFLL2026-10-21
06973660370520MinttiSuzhou Melodicare Medical Technology Co., Ltd.FLL2026-10-10
00195278949752TruSignal SpO2 MM 3.0MGE Healthcare Finland OyFLL2026-10-04
00195278949769TruSignal SpO2 MM 1.8MGE Healthcare Finland OyFLL2026-10-04
00198953002186Carescape Dock F0GE Healthcare Finland OyFLL2026-10-04
00198953009567Carescape ONEGE Healthcare Finland OyFLL2026-10-04
00749756389181DeRoyalDEROYAL INDUSTRIES, INC.FLL2026-09-21
00749756389204DeRoyalDEROYAL INDUSTRIES, INC.FLL2026-09-21
06944413835153Telemetry MonitorEdan Instruments, Inc.FLL2026-08-26
06944413835214Telemetry MonitorEdan Instruments, Inc.FLL2026-08-26
00885403523437HemoSphere AltaBecton, Dickinson And CompanyFLL2026-08-06
00885403523451HemoSphere AltaBecton, Dickinson And CompanyFLL2026-08-06
00885403523475HemoSphere AltaBecton, Dickinson And CompanyFLL2026-08-06
06970289030859foreverlittleHetaida Technology Co., LtdFLL2026-07-28
06953825911638ZKZOShenzhen Urion Technology Co., LtdFLL2026-07-23
B353UB25511UbiqVue MultiparameterLifesignals, Inc.FLL2026-07-20
06972040114334N/AShenzhen AOJ Medical Technology Co., LtdFLL2026-07-11
06972040114341N/AShenzhen AOJ Medical Technology Co., LtdFLL2026-07-11
06972040115522N/AShenzhen AOJ Medical Technology Co., LtdFLL2026-07-11
06931973457093CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
06931973457109CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
06970758502641CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
06970758508865CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
00850086928008SENSINEL™ CPM BASE STATIONAnalog Devices, Inc.FLL2026-06-03
00850086928015SENSINEL™ CPM WEARABLEAnalog Devices, Inc.FLL2026-06-03
00850086928022SENSINEL™ CARDIOPULMONARY MANAGEMENT (CPM) SYSTEM)Analog Devices, Inc.FLL2026-06-03
00850086928039SENSINEL™ CARDIOPULMONARY MANAGEMENT (CPM) SYSTEM)Analog Devices, Inc.FLL2026-06-03
08720256776567Corsano CardioWatch 287-2 SystemCorsano Health B.V.FLL2026-06-02
06926347900459joybabeShenzhen Brav Electronic Technologies Co., Ltd.FLL2026-06-01