Nellcor

Primary DI
10884521215931
Brand
Nellcor
Company
Covidien LP
Model
DLPM10N
Device description
Portable SpO2 Patient Monitoring System, DLPM10N
Published
2017-08-11
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
DQAOximeter

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
DQAOximeterCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K141542000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K141542000NELLCOR PORTABLE SPO2 PATIENT MONITORING SYSTEM ( NPSPMS )Covidien, LLC2014-10-02DQA

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10884521215931PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088452121593110884521215931

GMDN Terms#

Term, Definition table
TermDefinition
Carbon dioxide monitorA mains electricity (AC-powered) device intended to continuously measure the concentration of carbon dioxide (CO2) in a gas mixture through a particular method (e.g., electrochemical, infrared absorption, gas chromatographic, mass spectrometric) to determine a patient's ventilatory, circulatory, or metabolic status. It is typically used to measure end-tidal carbon dioxide (EtCO2) in expiratory gases during the administration of anaesthesia or during bedside monitoring. Commonly known as a capnograph or a capnometer, the sampling method can be "mainstream" and/or "sidestream".

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure52 KiloPascal106 KiloPascal
Handling Environment Humidity15 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature41 Degrees Fahrenheit104 Degrees Fahrenheit
Special Storage Condition, Specify00Fragile, Keep dry, Keep away from fire or flame
Storage Environment Atmospheric Pressure52 KiloPascal106 KiloPascal
Storage Environment Humidity15 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-4 Degrees Fahrenheit158 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521758803Vascufil8886470311V-22020-07-19
20884521082868VersaStepVS1015052016-09-24
10884521038967ValleylabE250510FRNSB2025-03-27
10884524002880ValleylabE250510FRNSB2025-03-27
10884521039100ValleylabE3310NSB2016-09-24
10884521141117WarmTouch50308902019-02-06
10884521205024Shiley4CN65R2016-09-24
10884521205420Shiley5CN70R2016-09-24
10884521205437Shiley6CN75R2016-09-24
10884521205444Shiley7CN80R2016-09-24
10884521205451Shiley8CN85R2016-09-24
10884521205468Shiley9CN90R2016-09-24
10884521205475Shiley10CN10R2016-09-24
10884521205482Shiley4UN65R2016-09-24
10884521205499Shiley5UN70R2016-09-24
10884521205505Shiley6UN75R2016-09-24
10884521205512Shiley7UN80R2016-09-24
10884521205529Shiley8UN85R2016-09-24
10884521205536Shiley9UN90R2016-09-24
10884521205543Shiley10UN10R2016-09-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
04048675785910Masimo SpO2 Module for Vista 300/SShanghai Draeger Medical Instrument Co.,Ltd.DQA2026-07-13
00010939962218N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
00093351041099N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
00845717013550N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
00845717013567N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
06972040113849N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
06972040113856N/AShenzhen AOJ Medical Technology Co., LtdDQA2026-07-11
06931973400563CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973400730CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973400785CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410326CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410333CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410340CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410364CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410371CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410388CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410395CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410401CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410418CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410425CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410432CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410449CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410456CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410647CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410678CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410685CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410692CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410715CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410722CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09
06931973410739CaremedShenzhen Caremed Medical Technology Co., Ltd.DQA2026-07-09