Mon-a-Therm

Primary DI
10884521828391
Brand
Mon-a-Therm
Company
Covidien LP
Model
90050
Device description
General Purpose Temperature Probe 400TM
Published
2023-05-29
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FLLThermometer, electronic, clinical

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FLLContinuous Measurement ThermometerGeneral Hospital2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K240077000
K874514000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K240077000Mon-a-Therm™ General Purpose Temperature Probe 400TM (90050, 90044)Covidien2024-08-20FLL
K874514000HI-LO TEMP(R) GENERAL PURPOSE TEMPERATURE PROBEMallinckrodt Critical Care1988-01-29FLL

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
20884521828398PackageGS150In Commercial Distribution
30884521828395PackageGS12In Commercial Distribution
10884521828391PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
2088452182839820884521828398
3088452182839530884521828395
1088452182839110884521828391

GMDN Terms#

Term, Definition table
TermDefinition
General-purpose patient temperature probe, single-useA temperature sensing device intended to be placed into a body orifice or on the body surface, and used in conjunction with a separate parent device with a display (e.g., electronic patient thermometer, infant warmer) to enable measurement/monitoring of a patient’s temperature; its use is not dedicated to a specific type of procedure. It is typically constructed of flexible materials (e.g., plastic or rubber) with a metal conducting core; the distal end of different device types will be designed for a particular application site. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Catheter Gauge9French

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Atmospheric Pressure12 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-25 Degrees Celsius55 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
1
Lot or batch
true
Expiration date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521852273BIS AdvancePMC80CB2026-10-26
10884521783829LigaSureMRASILF192026-10-23
10884521853812Shiley1108602026-10-25
10884521853829Shiley1108652026-10-25
10884521853836Shiley1108702026-10-25
10884521853843Shiley1108752026-10-25
10884521853850Shiley1108802026-10-25
10884521853867Shiley1108852026-10-25
10884521853874Shiley1108902026-10-25
10884521856547Touch SurgeryMDS300282026-10-23
10884521861114Vital SyncVITALSYNCSW032026-10-25
10884521039902Surgipro llVPF-703-MX2015-09-02
10884521063433Ti-CronX-11362015-09-02
10884521073951Versaport PlusNB8STF2016-09-24
10884521195677Surgipro IIVP-653-MX2015-09-02
10884521546349Surgipro IIVP86X2016-09-24
10884521701991MonosofCN793G2017-10-10
10884521702073Surgipro IIVP746XG2017-10-10
10884521702172SurgiproCP41G2017-10-10
10884521705173SurgiproSP690G2017-06-23

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
09120095900809SteadyTempSteadySense GmbHFLL2026-10-21
06973660370520MinttiSuzhou Melodicare Medical Technology Co., Ltd.FLL2026-10-10
00195278949752TruSignal SpO2 MM 3.0MGE Healthcare Finland OyFLL2026-10-04
00195278949769TruSignal SpO2 MM 1.8MGE Healthcare Finland OyFLL2026-10-04
00198953002186Carescape Dock F0GE Healthcare Finland OyFLL2026-10-04
00198953009567Carescape ONEGE Healthcare Finland OyFLL2026-10-04
00749756389181DeRoyalDEROYAL INDUSTRIES, INC.FLL2026-09-21
00749756389204DeRoyalDEROYAL INDUSTRIES, INC.FLL2026-09-21
06944413835153Telemetry MonitorEdan Instruments, Inc.FLL2026-08-26
06944413835214Telemetry MonitorEdan Instruments, Inc.FLL2026-08-26
00885403523437HemoSphere AltaBecton, Dickinson And CompanyFLL2026-08-06
00885403523451HemoSphere AltaBecton, Dickinson And CompanyFLL2026-08-06
00885403523475HemoSphere AltaBecton, Dickinson And CompanyFLL2026-08-06
06970289030859foreverlittleHetaida Technology Co., LtdFLL2026-07-28
06953825911638ZKZOShenzhen Urion Technology Co., LtdFLL2026-07-23
B353UB25511UbiqVue MultiparameterLifesignals, Inc.FLL2026-07-20
06972040114334N/AShenzhen AOJ Medical Technology Co., LtdFLL2026-07-11
06972040114341N/AShenzhen AOJ Medical Technology Co., LtdFLL2026-07-11
06972040115522N/AShenzhen AOJ Medical Technology Co., LtdFLL2026-07-11
06931973457093CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
06931973457109CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
06970758502641CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
06970758508865CaremedShenzhen Caremed Medical Technology Co., Ltd.FLL2026-07-09
00850086928008SENSINEL™ CPM BASE STATIONAnalog Devices, Inc.FLL2026-06-03
00850086928015SENSINEL™ CPM WEARABLEAnalog Devices, Inc.FLL2026-06-03
00850086928022SENSINEL™ CARDIOPULMONARY MANAGEMENT (CPM) SYSTEM)Analog Devices, Inc.FLL2026-06-03
00850086928039SENSINEL™ CARDIOPULMONARY MANAGEMENT (CPM) SYSTEM)Analog Devices, Inc.FLL2026-06-03
08720256776567Corsano CardioWatch 287-2 SystemCorsano Health B.V.FLL2026-06-02
06926347900459joybabeShenzhen Brav Electronic Technologies Co., Ltd.FLL2026-06-01
06942284618073One Step®JOYTECH HEALTHCARE CO.,LTDFLL2026-05-29