INVOS
- Primary DI
- 10884521845039
- Brand
- INVOS
- Company
- Covidien LP
- Model
- PMC71V-SF
- Device description
- rSO2 Preamplifier
- Published
- 2025-02-08
- Public version status
- Update
- Distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
- Rx
- true
Contact Domains#
Product Codes#
| Code | Name |
|---|---|
| MUD | Oximeter, tissue saturation |
Product Code Classifications#
| Code | Device | Specialty | Class |
|---|---|---|---|
| MUD | Oximeter, Tissue Saturation | Cardiovascular | 2 |
Premarket Submissions#
| Submission | Supplement |
|---|---|
| K211561 | 000 |
Premarket Details#
Identifiers And Packaging#
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| 20884521845036 | Package | GS1 | 12 | In Commercial Distribution |
| 10884521845039 | Primary | GS1 | 0 |
Alternate GTIN / UPC / EAN Codes
| Source identifier | GTIN-14 normalized |
|---|---|
| 20884521845036 | 20884521845036 |
| 10884521845039 | 10884521845039 |
GMDN Terms#
| Term | Definition |
|---|---|
| Tissue saturation oximeter | A mains electricity (AC-powered) photoelectric device that noninvasively calculates the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivered to that tissue, typically during circulatory or perfusion examinations of skeletal muscle or when there is a suspicion of compromised circulation. The device typically includes a monitor for data analysis and display, a light-transmitting cable, and a tissue-surface sensor. |
Storage And Handling#
| Type | Low | High | Condition |
|---|---|---|---|
| Handling Environment Atmospheric Pressure | 62 KiloPascal | 108 KiloPascal | |
| Handling Environment Humidity | 15 Percent (%) Relative Humidity | 95 Percent (%) Relative Humidity | |
| Handling Environment Temperature | 50 Degrees Fahrenheit | 95 Degrees Fahrenheit | |
| Special Storage Condition, Specify | 0 | 0 | Fragile, Keep dry |
| Storage Environment Atmospheric Pressure | 47 KiloPascal | 108 KiloPascal | |
| Storage Environment Humidity | 5 Percent (%) Relative Humidity | 95 Percent (%) Relative Humidity | |
| Storage Environment Temperature | -40 Degrees Fahrenheit | 158 Degrees Fahrenheit |
Contacts#
| Phone | |
|---|---|
| +1(508)261-8000 | covidien.udi@covidien.com |
Regulatory Flags#
- DUNS number
- 058614483
- Device count
- 1
- Serial number
- true
- Manufacturing date on label
- true
- No natural rubber latex
- true
Other Devices From This Company#
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 10884521758803 | Vascufil | 8886470311V-2 | 2020-07-19 | |
| 20884521082868 | VersaStep | VS101505 | 2016-09-24 | |
| 10884521038967 | Valleylab | E250510FRNSB | 2025-03-27 | |
| 10884524002880 | Valleylab | E250510FRNSB | 2025-03-27 | |
| 10884521039100 | Valleylab | E3310NSB | 2016-09-24 | |
| 10884521141117 | WarmTouch | 5030890 | 2019-02-06 | |
| 10884521205024 | Shiley | 4CN65R | 2016-09-24 | |
| 10884521205420 | Shiley | 5CN70R | 2016-09-24 | |
| 10884521205437 | Shiley | 6CN75R | 2016-09-24 | |
| 10884521205444 | Shiley | 7CN80R | 2016-09-24 | |
| 10884521205451 | Shiley | 8CN85R | 2016-09-24 | |
| 10884521205468 | Shiley | 9CN90R | 2016-09-24 | |
| 10884521205475 | Shiley | 10CN10R | 2016-09-24 | |
| 10884521205482 | Shiley | 4UN65R | 2016-09-24 | |
| 10884521205499 | Shiley | 5UN70R | 2016-09-24 | |
| 10884521205505 | Shiley | 6UN75R | 2016-09-24 | |
| 10884521205512 | Shiley | 7UN80R | 2016-09-24 | |
| 10884521205529 | Shiley | 8UN85R | 2016-09-24 | |
| 10884521205536 | Shiley | 9UN90R | 2016-09-24 | |
| 10884521205543 | Shiley | 10UN10R | 2016-09-24 |
Other Devices Sharing Product Codes#
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 00840682147811 | CARESCAPE Software | GE Healthcare Finland Oy | MUD | 2026-04-15 |
| 00690103219395 | Smart Pressure Controller | Edwards Lifesciences LLC | MUD | 2025-09-10 |
| 00690103219531 | Acumen IQ Plus | Edwards Lifesciences LLC | MUD | 2025-09-10 |
| 00690103219609 | VitaWave | Edwards Lifesciences LLC | MUD | 2025-09-10 |
| 00690103219616 | ForeSight IQ | Edwards Lifesciences LLC | MUD | 2025-07-11 |
| 00690103217711 | Acumen AFM™ cable - HemoSphere Alta™ monitor | Edwards Lifesciences LLC | MUD | 2025-07-11 |
| 00690103217728 | HemoSphere | Edwards Lifesciences LLC | MUD | 2025-07-11 |
| 10884521845985 | INVOS | Covidien LP | MUD | 2025-07-03 |
| 00690103217957 | HemoSphere Alta | Edwards Lifesciences LLC | MUD | 2025-03-13 |
| 00690103217964 | HemoSphere Alta | Edwards Lifesciences LLC | MUD | 2025-03-13 |
| 00690103217971 | HemoSphere Alta | Edwards Lifesciences LLC | MUD | 2025-03-13 |
| 20884521845036 | INVOS | Covidien LP | MUD | 2025-02-08 |
| 00690103218879 | HemoSphere Vita | Edwards Lifesciences LLC | MUD | 2024-08-28 |
| 00690103218886 | HemoSphere Vita | Edwards Lifesciences LLC | MUD | 2024-08-28 |
| 00690103211313 | ForeSight | Edwards Lifesciences LLC | MUD | 2024-08-26 |
| 00690103211320 | ForeSight | Edwards Lifesciences LLC | MUD | 2024-08-26 |
| 00690103211337 | ForeSight | Edwards Lifesciences LLC | MUD | 2024-08-26 |
| 50690103211318 | ForeSight | Edwards Lifesciences LLC | MUD | 2024-08-26 |
| 50690103211325 | ForeSight | Edwards Lifesciences LLC | MUD | 2024-08-26 |
| 50690103211332 | ForeSight | Edwards Lifesciences LLC | MUD | 2024-08-26 |
| 10884521701243 | INVOS | Covidien LP | MUD | 2024-04-14 |
| 10884521557048 | INVOS | Covidien LP | MUD | 2024-04-14 |
| B376KD2050 | SnapshotNIR | Kent Imaging Inc | MUD | 2024-04-05 |
| 00690103217124 | HemoSphere Vita | Edwards Lifesciences LLC | MUD | 2024-02-26 |
| 00690103218848 | HemoSphere Vita | Edwards Lifesciences LLC | MUD | 2024-02-26 |
| 00690103218855 | HemoSphere Vita | Edwards Lifesciences LLC | MUD | 2024-02-26 |
| 00690103218862 | HemoSphere Vita | Edwards Lifesciences LLC | MUD | 2024-02-26 |
| 10884521824409 | INVOS | Covidien LP | MUD | 2023-11-03 |
| 10884521824416 | INVOS | Covidien LP | MUD | 2023-11-03 |
| 00382830062947 | Component Neuromonitoring System | NATUS NEUROLOGY INCORPORATED | MUD | 2023-08-14 |