INVOS

Primary DI
10884521845039
Brand
INVOS
Company
Covidien LP
Model
PMC71V-SF
Device description
rSO2 Preamplifier
Published
2025-02-08
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
MUDOximeter, tissue saturation

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
MUDOximeter, Tissue SaturationCardiovascular2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K211561000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K211561000INVOS PM7100 Patient Monitor, INVOS Pediatric rSO2 Sensor, INVOS Infant Regional Saturation Sensor (also referred to as OxyAlert NIRSensor)Covidien, LLC2021-12-05MUD

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
20884521845036PackageGS112In Commercial Distribution
10884521845039PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
2088452184503620884521845036
1088452184503910884521845039

GMDN Terms#

Term, Definition table
TermDefinition
Tissue saturation oximeterA mains electricity (AC-powered) photoelectric device that noninvasively calculates the percent oxygen saturation of haemoglobin in a volume of tissue (StO2) to assess the amount of oxygen delivered to that tissue, typically during circulatory or perfusion examinations of skeletal muscle or when there is a suspicion of compromised circulation. The device typically includes a monitor for data analysis and display, a light-transmitting cable, and a tissue-surface sensor.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure62 KiloPascal108 KiloPascal
Handling Environment Humidity15 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Handling Environment Temperature50 Degrees Fahrenheit95 Degrees Fahrenheit
Special Storage Condition, Specify00Fragile, Keep dry
Storage Environment Atmospheric Pressure47 KiloPascal108 KiloPascal
Storage Environment Humidity5 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-40 Degrees Fahrenheit158 Degrees Fahrenheit

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
1
Serial number
true
Manufacturing date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521703827Tri-Staple 2.0SIGCIR21MTORVIL2026-08-09
10884521703834Tri-Staple 2.0SIGCIR21XTORVIL2026-08-09
10884521703841Tri-Staple 2.0SIGCIR25MTORVIL2026-08-09
10884521703858Tri-Staple 2.0SIGCIR25XTORVIL2026-08-09
10884521782648ValleylabE105202021-07-12
10884521703797Tri-Staple 2.0SIGCIR21XT2026-07-31
10884521703810Tri-Staple 2.0SIGCIR25XT2026-07-31
10884521102163Vascufil88864788-05V2015-08-31
10884522006545Shiley10DCFS2015-08-28
10884522030021Shiley5.0 PDL2015-09-15
10884522030083Shiley6.0 PDL2015-09-15
20884522029022Shiley8DCT2015-08-31
20884522029114Shiley4.5PDC2015-10-20
20884522031957Shiley10LPC-S2015-08-28
20884522031964Shiley4LPC-S2015-08-28
20884522031988Shiley8LPC-S2017-05-25
30884522026653Shiley3.0 NEO2015-09-15
30884522026684Shiley4.5 NEO2015-10-12
10884521833869EndoflipEF-301-RFB2024-04-12
10884521855359GI GeniusGGM300-US-RFB2026-07-26

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00840682147811CARESCAPE SoftwareGE Healthcare Finland OyMUD2026-04-15
00690103219395Smart Pressure ControllerEdwards Lifesciences LLCMUD2025-09-10
00690103219531Acumen IQ PlusEdwards Lifesciences LLCMUD2025-09-10
00690103219609VitaWaveEdwards Lifesciences LLCMUD2025-09-10
00690103219616ForeSight IQEdwards Lifesciences LLCMUD2025-07-11
00690103217711Acumen AFM™ cable - HemoSphere Alta™ monitorEdwards Lifesciences LLCMUD2025-07-11
00690103217728HemoSphereEdwards Lifesciences LLCMUD2025-07-11
10884521845985INVOSCovidien LPMUD2025-07-03
00690103217957HemoSphere AltaEdwards Lifesciences LLCMUD2025-03-13
00690103217964HemoSphere AltaEdwards Lifesciences LLCMUD2025-03-13
00690103217971HemoSphere AltaEdwards Lifesciences LLCMUD2025-03-13
20884521845036INVOSCovidien LPMUD2025-02-08
00690103218879HemoSphere VitaEdwards Lifesciences LLCMUD2024-08-28
00690103218886HemoSphere VitaEdwards Lifesciences LLCMUD2024-08-28
00690103211313ForeSightEdwards Lifesciences LLCMUD2024-08-26
00690103211320ForeSightEdwards Lifesciences LLCMUD2024-08-26
00690103211337ForeSightEdwards Lifesciences LLCMUD2024-08-26
50690103211318ForeSightEdwards Lifesciences LLCMUD2024-08-26
50690103211325ForeSightEdwards Lifesciences LLCMUD2024-08-26
50690103211332ForeSightEdwards Lifesciences LLCMUD2024-08-26
10884521701243INVOSCovidien LPMUD2024-04-14
10884521557048INVOSCovidien LPMUD2024-04-14
B376KD2050SnapshotNIRKent Imaging IncMUD2024-04-05
00690103217124HemoSphere VitaEdwards Lifesciences LLCMUD2024-02-26
00690103218848HemoSphere VitaEdwards Lifesciences LLCMUD2024-02-26
00690103218855HemoSphere VitaEdwards Lifesciences LLCMUD2024-02-26
00690103218862HemoSphere VitaEdwards Lifesciences LLCMUD2024-02-26
10884521824409INVOSCovidien LPMUD2023-11-03
10884521824416INVOSCovidien LPMUD2023-11-03
00382830062947Component Neuromonitoring SystemNATUS NEUROLOGY INCORPORATEDMUD2023-08-14