Valleylab

Primary DI
10884524000404
Brand
Valleylab
Company
Covidien LP
Model
E2781-28
Device description
Laparoscopic Curved Spatula Electrode,Hollow
Published
2016-09-24
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K964175000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K964175000VALLEYLAB E2750 LAPAROSCOPIC HANDSET, VALLEYLAB E2770 SERIES ELECTRODESValleylab, Inc.1996-12-05GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
20884524000401PackageGS125In Commercial Distribution
30884524000408PackageGS110In Commercial Distribution
10884524000404PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
2088452400040120884524000401
3088452400040830884524000408
1088452400040410884524000404

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic electrosurgical handpiece/electrode, bipolar, single-useA sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery, and may in addition be intended for open surgery; it is not intended for focal percutaneous ablation. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps, rigid probe with controls). This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length28Centimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity0 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature-29 Degrees Fahrenheit149 Degrees Fahrenheit

Contacts#

Phone, Email table
PhoneEmail
+1(508)261-8000covidien.udi@covidien.com

Regulatory Flags#

DUNS number
058614483
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10884521038967ValleylabE250510FRNSB2025-03-27
10884524002880ValleylabE250510FRNSB2025-03-27
10884521039100ValleylabE3310NSB2016-09-24
10884521141117WarmTouch50308902019-02-06
10884521205024Shiley4CN65R2016-09-24
10884521205420Shiley5CN70R2016-09-24
10884521205437Shiley6CN75R2016-09-24
10884521205444Shiley7CN80R2016-09-24
10884521205451Shiley8CN85R2016-09-24
10884521205468Shiley9CN90R2016-09-24
10884521205475Shiley10CN10R2016-09-24
10884521205482Shiley4UN65R2016-09-24
10884521205499Shiley5UN70R2016-09-24
10884521205505Shiley6UN75R2016-09-24
10884521205512Shiley7UN80R2016-09-24
10884521205529Shiley8UN85R2016-09-24
10884521205536Shiley9UN90R2016-09-24
10884521205543Shiley10UN10R2016-09-24
10884521815360NellcorMAXFAST2021-08-09
10884521815469NellcorMAXFASTI2021-08-09

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776398484MillenniumAvalign Technologies, Inc.GEI2026-07-16
08800020100276INTRAcel TipJeisys Medical Inc.GEI2026-07-16
08800020100283INTRAcel TipJeisys Medical Inc.GEI2026-07-16
08800020100306INTRAcel TipJeisys Medical Inc.GEI2026-07-16
08800020100313INTRAcel TipJeisys Medical Inc.GEI2026-07-16
08800020100320INTRAcel TipJeisys Medical Inc.GEI2026-07-16
08800020100337INTRAcel TipJeisys Medical Inc.GEI2026-07-16
08800020104984DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020104991DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020105004DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020105059DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020105066DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020105073DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020106827DENSITY TipJeisys Medical Inc.GEI2026-07-16
08800020107626DENSITY HandpieceJeisys Medical Inc.GEI2026-07-16
08800020107633DENSITY HandpieceJeisys Medical Inc.GEI2026-07-16
08800020110565INTRAcel HandpieceJeisys Medical Inc.GEI2026-07-16
08800020110572INTRAcel HandpieceJeisys Medical Inc.GEI2026-07-16
08800020110640FootswitchJeisys Medical Inc.GEI2026-07-16
B382SD08890310101D0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD08890320101D0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD7720520001Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD7720585030Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD84032220032B0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD8406210032B0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89029200Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89039060Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89139290Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD8917450Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89179290Surgical DirectSurgical Direct, Inc.GEI2026-07-14