NA

Primary DI
10885862052230
Brand
NA
Company
Exactech, Inc.
Model
205-56-05
Catalog number
205-56-05
Device description
STEM EXTENSION REAMER, 19mm
Published
2022-08-25
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Product Codes#

Code, Name table
CodeName
JWHPROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JWHProsthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/PolymerOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K012251000
K933610000
K935726000
K954208000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K012251000OPTETRAK TOTAL KNEE SYSTEM, STRAIGHT STEM EXTENSIONS - ADDITIONAL SIZESExactech, Inc.2001-07-31JWH
K933610000EXACTECH CEMENTED TOTAL KNEE SYSTEM, TIBIAL COMPONENTSExactech, Inc.1995-01-17JWH
K935726000EXACTECH POROUS COATED CRUCIATE RETAINED FEMORAL COMPONENTExactech, Inc.1994-10-20JWH
K954208000OPTETRAK CONSTRAINED CONDYLAR KNEE FOR CEMENTED USE ONLYExactech, Inc.1996-02-26JWH

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10885862052230PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088586205223010885862052230

GMDN Terms#

Term, Definition table
TermDefinition
Medullary canal orthopaedic reamer, rigidAn orthopaedic surgical instrument designed to open and enlarge the medullary canal (e.g., in the femur, tibia, ulnar) for the insertion of various devices during prosthesis implantation or fracture fixation procedures. It is typically designed as a long, cylindrical, rigid shaft with straight, spiralled, or contoured flutes that function as cutting surfaces; it may include a transverse milling (spotfacing) burr to level the end of the bone (e.g., post amputation). It is typically made of a high-grade stainless steel and is available in various sizes. It is intended for manual or powered rotation. This is a reusable device intended to be sterilized prior to use.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Outer Diameter19Millimeter

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
157565946
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10885862032102Novation160-20-11160-20-112015-08-10
10885862064035Optetrak244-24-09244-24-092015-10-30
10885862307132Truliant02-022-49-251102-022-49-25112017-05-16
10885862313058Optetrak Logic02-012-44-260902-012-44-26092017-02-16
10885862313065Optetrak Logic02-012-44-261102-012-44-26112017-02-16
10885862313072Optetrak Logic02-012-44-261302-012-44-26132017-02-16
10885862313089Optetrak Logic02-012-44-261502-012-44-26152017-02-16
10885862313218Optetrak Logic02-012-35-210902-012-35-21092017-02-16
10885862313225Optetrak Logic02-012-35-211102-012-35-21112017-02-16
10885862313232Optetrak Logic02-012-35-211302-012-35-21132017-02-16
10885862316271Optetrak Logic02-012-35-211702-012-35-21172017-02-16
10885862316288Optetrak Logic02-012-35-211902-012-35-21192017-02-16
10885862316356Optetrak Logic02-012-44-261702-012-44-26172017-02-16
10885862316363Optetrak Logic02-012-44-261902-012-44-26192017-02-16
10885862135049NAT2-5052T2-50522022-09-19
10885862135056NAT2-5458T2-54582022-09-19
10885862135063NAT2-6064T2-60642022-09-19
10885862135070NAT2-6670T2-66702022-09-19
10885862135636NAT8-4448T8-44482022-09-19
10885862135643NAT8-5052T8-50522022-09-19

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
E31442411410SignatureMaterialise NVJWH2026-09-24
E31442422415SignatureMaterialise NVJWH2026-09-24
E31442422450SignatureMaterialise NVJWH2026-09-24
E31442422451SignatureMaterialise NVJWH2026-09-24
E31442422452SignatureMaterialise NVJWH2026-09-24
E31442422453SignatureMaterialise NVJWH2026-09-24
E31442422455SignatureMaterialise NVJWH2026-09-24
E31442422456SignatureMaterialise NVJWH2026-09-24
E31442422457SignatureMaterialise NVJWH2026-09-24
E31442422458SignatureMaterialise NVJWH2026-09-24
E31442422460SignatureMaterialise NVJWH2026-09-24
E31442422461SignatureMaterialise NVJWH2026-09-24
E31442422462SignatureMaterialise NVJWH2026-09-24
E31442422463SignatureMaterialise NVJWH2026-09-24
E31442422465SignatureMaterialise NVJWH2026-09-24
E31442422466SignatureMaterialise NVJWH2026-09-24
E31442422467SignatureMaterialise NVJWH2026-09-24
E31442422468SignatureMaterialise NVJWH2026-09-24
E31442422470SignatureMaterialise NVJWH2026-09-24
E31442422471SignatureMaterialise NVJWH2026-09-24
E31442422472SignatureMaterialise NVJWH2026-09-24
E31442422473SignatureMaterialise NVJWH2026-09-24
E31442422475SignatureMaterialise NVJWH2026-09-24
E31442422476SignatureMaterialise NVJWH2026-09-24
E31442422477SignatureMaterialise NVJWH2026-09-24
E31442422478SignatureMaterialise NVJWH2026-09-24
E31442422650SignatureMaterialise NVJWH2026-09-24
E31442422651SignatureMaterialise NVJWH2026-09-24
E31442422652SignatureMaterialise NVJWH2026-09-24
E31442422653SignatureMaterialise NVJWH2026-09-24