NA

Primary DI
10886705028702
Brand
NA
Company
Medos International Sàrl
Model
242302
Catalog number
242302
Device description
HD CAMERA CONTROL SYSTEM WITH INTEGRATED LIGHT SOURCE
Published
2017-10-26
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
FCWLight source, fiberoptic, routine
GCJLaparoscope, general & plastic surgery

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
FCWLight Source, Fiberoptic, RoutineGastroenterology, Urology2
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K123359000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K123359000OVS1 VIDEO SYSTEMOlive Medical Corp.2012-12-19FCW

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10886705028702PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088670502870210886705028702

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic video image processing/light source systemA mains electricity (AC-powered) unit/assembly that, when used with an appropriate endoscope (not included), is designed to both: 1) produce a source of cold light for endoscopic imaging; and 2) receive and process electronic video image signals sent from the endoscope/endoscopic video camera. It may additionally include image recording features and an image display monitor, however it does not include features to steer, propel or otherwise control the movement of the endoscope.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure500 millibar1060 millibar
Handling Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Handling Environment Temperature-10 Degrees Celsius50 Degrees Celsius
Handling Environment Temperature14 Degrees Fahrenheit122 Degrees Fahrenheit
Special Storage Condition, Specify00Waste from Electrical and Electronic Equipment
Storage Environment Atmospheric Pressure500 millibar1060 millibar
Storage Environment Humidity10 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius50 Degrees Celsius
Storage Environment Temperature14 Degrees Fahrenheit122 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(800)255-2500xx@xx.xx

Regulatory Flags#

DUNS number
482661753
Device count
1
Serial number
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10886705032266NA2423332423332026-07-22
10886705001309RIGIDFIX BIOCRYL2108162108162015-09-01
10705034647302CROSSNAV CONDUIT3010-21-9963010219962026-07-09
10705034647319CROSSNAV CONDUIT3010-21-9993010219992026-07-09
10705034647326CROSSNAV CONDUIT3010-21-3323010213322026-07-09
10705034647333CROSSNAV CONDUIT3010-21-3313010213312026-07-09
10705034647340CROSSNAV CONDUIT3010-21-2103010212102026-07-09
10705034647357CROSSNAV CONDUIT3010-21-2113010212112026-07-09
10705034647364CROSSNAV CONDUIT3010-21-2123010212122026-07-09
10705034647371CROSSNAV CONDUIT3010-21-2133010212132026-07-09
10705034647388CROSSNAV CONDUIT3010-21-2143010212142026-07-09
10705034647395CROSSNAV CONDUIT3010-21-2153010212152026-07-09
10705034647418CROSSNAV CONDUIT3010-21-2083010212082026-07-09
10705034647425CROSSNAV CONDUIT3010-21-2093010212092026-07-09
10705034647432CROSSNAV CONDUIT3010-21-3203010213202026-07-09
10705034647449CROSSNAV CONDUIT3010-21-3153010213152026-07-09
10705034647456CROSSNAV CONDUIT3010-21-9983010219982026-07-09
10705034647463N/A3010-21-3403010213402026-07-09
10705034647470CROSSNAV CONDUIT3010-21-3013010213012026-07-09
10705034647487CROSSNAV CONDUIT3010-21-3033010213032026-07-09

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776422110MillenniumAvalign Technologies, Inc.GCJ2026-07-24
00198506091957ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-07-22
00198506092848ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-07-22
00198506092862ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-07-22
14026704645333WECKTELEFLEX INCORPORATEDGCJ2026-07-21
00198506092176ELMED INCORPORATEDELMED INCORPORATEDGCJ2026-07-17
00888867561793Arthrex®ARTHREX, INC.GCJ2026-07-17
B382SD90781001000Surgical DirectSurgical Direct, Inc.GCJ2026-07-17
B382SD9918100Surgical DirectSurgical Direct, Inc.GCJ2026-07-17
B382SD1184590Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD12711090Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD1271390Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD1271590Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD13018770Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD13168350Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD23373490Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD770561050Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD775011530Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD775021630Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD77505650Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD7751586C0Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
B382SD7751587C0Surgical DirectSurgical Direct, Inc.GCJ2026-07-14
00850045863012ArthroFree® 2 ReceiverLazurite Holdings LLCGCJ2026-07-10
00850045863029ArthroFree® 2 Wireless Camera HeadLazurite Holdings LLCGCJ2026-07-10
00850045863036ArthroFree® 2 Operating Room KitLazurite Holdings LLCGCJ2026-07-10
00850045863043ArthroFree® 2 Single Camera Head SetLazurite Holdings LLCGCJ2026-07-10
B382SD883110450Surgical DirectSurgical Direct, Inc.GCJ2026-07-10
B382SD88324450Surgical DirectSurgical Direct, Inc.GCJ2026-07-10
00190776421731MillenniumAvalign Technologies, Inc.GCJ2026-06-24
00190776421663MillenniumAvalign Technologies, Inc.GCJ2026-06-23