CHESAPEAKE® Stabilization System

Primary DI
10888857404403
Brand
CHESAPEAKE® Stabilization System
Company
VB Spine LLC
Model
SP-3044
Catalog number
SP-3044
Device description
T-Handle Tightener
Published
2018-05-03
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
OVDIntervertebral fusion device with integrated fixation, lumbar
OVEIntervertebral fusion device with integrated fixation, cervical

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
OVDIntervertebral Fusion Device With Integrated Fixation, LumbarOrthopedic2
OVEIntervertebral Fusion Device With Integrated Fixation, CervicalOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K142487000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K142487000Chesapeake Stabilization SystemK2m, Inc.2015-05-07OVD

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10888857404403PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1088885740440310888857404403

GMDN Terms#

Term, Definition table
TermDefinition
Orthopaedic prosthesis implantation instrument, reusableA hand-held surgical instrument intended to be used during implantation of an orthopaedic prosthesis, either manually or as a computer-assisted surgery (CAS) device, to aid in the navigation/placement of the prosthesis or other instruments. It may be used for the following applications: 1) to hold/align/fix bone preparation instruments, prosthesis, or prosthesis component; 2) to provide relative position landmarks; 3) to ascertain correct spatial orientation or limb alignment; and/or 4) as an interface between prosthesis components. This is a reusable device intended to be sterilized prior to use.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(703)777-3155mzellers@k2m.com
+1(571)919-2000mark.zellers@stryker.com

Regulatory Flags#

DUNS number
119508156
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10888857487048EVEREST® Spinal SystemSP-5002SP-50022020-10-13
10888857158313TERRA NOVA® MI Access System1501-900601501-900602021-01-29
10888857596894OZARK Cervical Plate SystemPRO-1427-01PRO-1427-012026-05-28
10888857596719Xia® 3PRO-1432-01PRO-1432-012026-05-12
10888857596726Xia® 3PRO-1432-02PRO-1432-022026-05-12
10888857596733Xia® 3PRO-1432-03PRO-1432-032026-05-12
10888857219656CASCADIA™ Interbody System6101-2224012LL8-G26101-2224012LL8-G22016-12-30
10888857219793CASCADIA™ Interbody System6101-2226014LL8-G26101-2226014LL8-G22015-12-16
10888857220966CASCADIA™ Interbody System6101-2224510LL12-G26101-2224510LL12-G22016-12-30
10888857221093CASCADIA™ Interbody System6101-2226012LL12-G26101-2226012LL12-G22016-12-30
10888857221871CASCADIA™ Interbody System6101-2225014LL15-G26101-2225014LL15-G22016-12-30
10888857221895CASCADIA™ Interbody System6101-2226014LL15-G26101-2226014LL15-G22016-12-30
10888857346420CANYON™ Retractor Systems6401-901076401-901072020-06-18
10888857035553RAVINE® Lateral Access System2701-900722701-900722022-02-14
10888857596900OZARK Cervical Plate SystemPRO-1427-10PRO-1427-102026-05-01
10888857596917OZARK Cervical Plate SystemPRO-1427-12PRO-1427-122026-05-01
10888857596924OZARK Cervical Plate SystemPRO-1427-14PRO-1427-142026-05-01
10888857596931OZARK Cervical Plate SystemPRO-1427-16PRO-1427-162026-05-01
10888857596948OZARK Cervical Plate SystemPRO-1427-18PRO-1427-182026-05-01
10888857218765CASCADIA™ Interbody System6101-2224508LP-G26101-2224508LP-G22015-12-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776391560CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391577CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391584CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391591CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391607CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391614CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391621CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391638CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391645CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391652CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391669CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391676CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-09
00190776391553CONDUIT ZERO-P VAAvalign Technologies, Inc.OVE2026-07-08
00810017916450Saber-CELEVATION SPINE, INC.OVE2026-07-07
00810017916467Saber-CELEVATION SPINE, INC.OVE2026-07-07
00810017916474Saber-CELEVATION SPINE, INC.OVE2026-07-07
00810017916481Saber-CELEVATION SPINE, INC.OVE2026-07-07
00810017916498Saber-CELEVATION SPINE, INC.OVE2026-07-07
00810017913893Saber-C Body (PT), 14x17x6 6 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017913909Saber-C Body (PT), 14x17x7 6 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017913916Saber-C Body (PT), 14x17x8 6 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017913923Saber-C Body (PT), 14x17x9 6 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914357Saber-C Plate, 12x15x5 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914364Saber-C Plate, 12x15x6 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914371Saber-C Plate, 12x15x7 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914388Saber-C Plate, 12x15x8 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914395Saber-C Plate, 12x15x9 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914401Saber-C Plate, 12x15x10 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00810017914630Saber-C Plate, 14x17x9 12 deg.ELEVATION SPINE, INC.OVE2026-06-25
00763000880477|Endoskeleton™ TCS Interbody SystemMEDTRONIC SOFAMOR DANEK, INC.OVE2026-06-22