PERCUVANCE

Primary DI
14026704582874
Brand
PERCUVANCE
Company
TELEFLEX INCORPORATED
Model
IPN027876
Catalog number
PCVRH
Device description
RATCHETED HANDLE
Published
2017-11-16
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, cutting & coagulation & accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K153063000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K153063000PERCUVANCE PERCUTANEOUS SURGICAL SYSTEMTeleflexmedical, Inc.2016-04-08GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
04026704582877Direct MarkingGS10
14026704582874PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
04026704582877040267045828774026704582877
1402670458287414026704582874

GMDN Terms#

Term, Definition table
TermDefinition
Surgical instrument handle, non-torque-limitingA hand-held manual surgical instrument designed to attach to the proximal end of a surgical instrument (e.g., a screwdriver shaft) to allow the surgeon to perform manipulations with the instrument, such as manual rotation of a bone screw or reamer; it does not include a torque-limiting function. The device is typically made of metal and/or synthetic material and may have a straight or T-shaped handle grip which may include additional features such as a ratchet mechanism to allow the surgeon to maintain a constant hold on the handle when providing rotation in one direction. This is a reusable device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Length5Inch
Width5.8Inch

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Temperature-29 Degrees Celsius60 Degrees Celsius
Storage Environment Temperature16 Degrees Celsius37 Degrees Celsius

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(919)544-8000CS@TELEFLEX.COM

Regulatory Flags#

DUNS number
002348191
Device count
1
Lot or batch
true
Manufacturing date on label
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10801902228205ARROWIPNB00283ASK-45703-NCC32026-09-25
10801902228212ARROWIPNB00282ASK-45802-NCC2026-09-25
10801902228700ARROWCDC-09903-1ACDC-09903-1A2026-09-22
10801902228717ARROWCDA-42703-XPCN1ACDA-42703-XPCN1A2026-09-22
04026704916955RUSCHIPN9007315640002026-08-03
10841156111519TELEFLEXIPN93068158822025-06-12
10841156111540TELEFLEXIPN93068258842025-06-12
10841156111595TELEFLEXIPN93068458882025-06-12
10841156111755TELEFLEXIPN93068358862025-06-12
14026704302182RUSCHIPN0505091807051202016-09-16
14026704302205RUSCHIPN0505111807051402016-09-16
14026704302229RUSCHIPN0505131807051602016-09-16
14026704302243RUSCHIPN0505151807051802016-09-16
14026704302267RUSCHIPN0505171807052002016-09-16
14026704302281RUSCHIPN0505191807052202016-09-16
14026704302304RUSCHIPN0505211807052402016-09-16
14026704302328RUSCHIPN0505231807052602016-09-16
14026704302342RUSCHIPN0505251807052802016-09-16
14026704302366RUSCHIPN0505271807053002016-09-16
14026704302977RUSCHIPN0505911834052002016-09-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00197998302718Solventumâ„¢Solventum US LLCGEI2026-09-25
00724995269586Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269951Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00724995269968Snowden-PencerSTERIS Deutschland GmbHGEI2026-09-25
00190776432300MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432317MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432324MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432430MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432447MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776432454MillenniumAvalign Technologies, Inc.GEI2026-09-24
00190776431457MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432041MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432195MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776432201MillenniumAvalign Technologies, Inc.GEI2026-09-22
00190776431181MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431198MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431204MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431211MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431228MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431235MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431242MillenniumAvalign Technologies, Inc.GEI2026-09-21
00190776431259MillenniumAvalign Technologies, Inc.GEI2026-09-21
10840113236852BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236890BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113236937BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237040BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237064BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237101BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237118BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21
10840113237132BovieASPEN SURGICAL PRODUCTS, INC.GEI2026-09-21