FUJIFILM

Primary DI
14547410093299
Brand
FUJIFILM
Company
FUJIFILM CORPORATION
Model
SB-500B/D
Device description
This product is intended to suck the body fluid and blood, etc by attaching the endoscope.
Published
2016-10-18
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
false
OTC
false
Sterile
false
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
EOQBRONCHOSCOPE (FLEXIBLE OR RIGID)
FFYAdaptor, Bulbs, Miscellaneous, For Endoscope

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
EOQBronchoscope (Flexible Or Rigid)Ear, Nose, Throat2
FFYAdaptor, Bulbs, Miscellaneous, For EndoscopeGastroenterology, Urology1

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K122535000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K122535000FUJINON/FUJIFILM EB-530 SERIES BRONCHOSCOPES (EB-530S, EB-530T AND EB-530HFujifilm Medical System U.S.A., Inc.2012-12-13EOQ

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
14547410093299PackageGS120In Commercial Distribution
04547410093292PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
1454741009329914547410093299
04547410093292045474100932924547410093292

GMDN Terms#

Term, Definition table
TermDefinition
Flexible video bronchoscope, reusableAn endoscope with a flexible inserted portion for endoscopic procedures of the airways and tracheobronchial tree (i.e., bronchoscopy). It is inserted through the mouth or nose during bronchoscopy. Anatomical images are transmitted to the user by a video system with a charge-coupled device (CCD) chip at the distal end and the images showing on a monitor. It is commonly used to diagnose lung infections, pneumonia, or lung cancer, and allows physicians to view the insides of the lungs and take biopsies and samples of secretions. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Special Storage Condition, Specify00There must be no condensation.
Storage Environment Atmospheric Pressure70 KiloPascal106 KiloPascal
Storage Environment Humidity10 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Humidity30 Percent (%) Relative Humidity85 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius60 Degrees Celsius
Storage Environment Temperature10 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method
High-level Disinfectant;Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+018002728465xxx@xxx.xxx

Regulatory Flags#

DUNS number
713565195
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
false
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
04547410480269FUJIFILMVS-10002026-05-22
04547410529128FUJIFILMEG-S100XT2026-05-22
04573596200865APERTO LucentMR-JCR-82Joint coil (M) MR-JCR-82 for APERTO Lucent/APEROT 2026-05-22
04573596200889APERTO LucentMR-JC-81Joint coil (S) MRJC-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200896APERTO LucentMR-JCR-83Joint coil (L) MR-JCR-83 for APERTO Lucent/APEROT 2026-05-22
04573596200902APERTO LucentMR-CSC-81C-Spine coil MR-SCS-81 for APERTO Lucent/APERTO Et2026-05-22
04573596200940APERTO LucentMR-QWC-81Wrist coil MR-QWC-81 for APERTO Lucent/Aperto Eter2026-05-22
04573596200964APERTO LucentMR-MSC-81Shoulder coil MR-MSC-81 for APERTO Lucent/APERTO E2026-05-22
04573596200971APERTO LucentMR-QRC-81Head coil (L) MR-QRC-81 for APERTO Lucent/APERTO E2026-05-22
04573596201480APERTO LucentMR-QHC-81RQD Head coil R MR-QHC-81R for APERTO Lucent2026-05-22
04573596201497APERTO LucentMR-QKC-83RQD Knee coil R MR-QKC-83R for APERTO Lucent2026-05-22
04573596201503APERTO LucentMR-IBC-83Open body coil MR-IBC-83 for APERTO Lucent/APERTO 2026-05-22
04573596202210APERTO LucentMR-QFC-82NFlexible Body coil N(M) MR-QFC-82N for APERTO Luce2026-05-22
04573596202227APERTO LucentMR-QFC-83NFlexible Body coil N(L) MR-QFC-83N for APERTO Luce2026-05-22
04573596200704APERTO LucentAPERTO LucentAPERTO Lucent2024-09-19
04547410334494Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B15-2016-09-16
04547410334500Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B20-2016-09-16
04547410334517Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B25-2016-09-16
04547410334524Fujifilm Diathermic Slitter (FlushKnife)DK2618J -B30-2016-09-16
04547410334531Fujifilm Diathermic Slitter (FlushKnife)DK2618J -N10-2016-09-16

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
10810068810841MONARCH™ Navigation SensorsAuris Health, Inc.EOQ2026-05-27
10810068810858MONARCH™ ControllerAuris Health, Inc.EOQ2026-05-27
04719872715108MiiS Horus scopeMEDIMAGING INTEGRATED SOLUTION INC.EOQ2026-04-29
04719872715115MiiS Horus scopeMEDIMAGING INTEGRATED SOLUTION INC.EOQ2026-04-29
04719872715122MiiS Horus scopeMEDIMAGING INTEGRATED SOLUTION INC.EOQ2026-04-29
04719872715283MiiS Horus Endoscope Display SystemMEDIMAGING INTEGRATED SOLUTION INC.EOQ2026-04-29
04719872715290MiiS Horus Endoscope Display SystemMEDIMAGING INTEGRATED SOLUTION INC.EOQ2026-04-29
00856571007265EasyPath RF Introducer SheathBRONCUS MEDICAL INC.EOQ2026-04-23
04897106957880andorate® 2-piece Cleaning Adapter + 3-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957897andorate® 2-piece Cleaning Adapter + 4-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957941andorate® 2-piece Cleaning Adapter + 3-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106957958andorate® 2-piece Cleaning Adapter + 4-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106958016andorate® 2-piece Cleaning Adapter + 3-piece Valve KitGA Health Company LimitedFFY2026-03-13
04897106958023andorate® 2-piece Cleaning Adapter + 4-piece Valve KitGA Health Company LimitedFFY2026-03-13
04547410520583FUJIFILMFUJIFILM CORPORATIONEOQ2026-01-23
04897106957743andorate® Air Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-11-21
00850048825086Galaxy System (Cart) - RefurbishedNoah Medical CorporationEOQ2025-10-25
04547410564112FUJIFILMFUJIFILM CORPORATIONFFY2025-10-24
10810068810896Monarch Bronchscope 2.0/Monarch Platform (P2), RefurbishedAuris Health, Inc.EOQ2025-08-04
10810068811169Monarch Platform, Bronchoscopy 4.1, RefurbishedAuris Health, Inc.EOQ2025-08-04
04897106957804Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957811Biopsy Port Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957828Air/Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-08-04
04897106957071Air Water Channel Cleaning AdapterGA Health Company LimitedFFY2025-07-31
10810068811510Monarch™ Laptop P17 Software v4.1.1Auris Health, Inc.EOQ2025-06-04
10810068811527Monarch™ Laptop P16 Software v4.1.1Auris Health, Inc.EOQ2025-06-04
04547410513790FUJIFILMFUJIFILM CORPORATIONEOQ2025-05-31
00850025860857CO2 Source Tubing Adapter Olympus UCRMicro-tech UsaFFY2025-05-12
00850025860864CO2 Source Tubing Adapter Fuji GW100Micro-tech UsaFFY2025-05-12
10810068810988Monarch Platform, Bronchoscopy 4.1Auris Health, Inc.EOQ2025-03-03