Primary DI
18033695727456
Brand
NA
Company
FIAB SPA
Model
F7244/1
Catalog number
F7244/1
Device description
HTC (high temperature cautery) F7244/1 model is a sterile bipolar battery operated disposable device used for the cauterization of tissues and capillary vessels. F7244/1 model is equipped with fine tip that permits the cauterization of very small vessels and is suitable to be used all the times a quick and precise cauterization is necessary. F7244/1 reaches a maximum working temperature of 1.200°C (2.200 °F).
Published
2020-05-14
Public version status
Update
Distribution status
Not in Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K100333000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K100333000FIAB SPA, MODELS F7244, F7233, F7234, F7277Fiab Spa2010-06-21GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
28033695727453PackageGS150In Commercial Distribution
38033695727450PackageGS136In Commercial Distribution
18033695727456PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
2803369572745328033695727453
3803369572745038033695727450
1803369572745618033695727456

GMDN Terms#

Term, Definition table
TermDefinition
Electrocautery system generator, battery-poweredA battery-powered device that produces and delivers a regulated electrical current used to heat the electrode tip or wire loop of a cutting instrument used during surgical intervention to burn or sear body tissue. It is used to stop bleeding (cauterization of blood vessels), to treat superficial skin lesions, e.g., the removal of warts, the removal of gastrointestinal polyps via an appropriate endoscope, or to occlude fallopian tubes during sterilization procedures. It will typically contain electronic circuits and have a built-in thermocoupler to help control the temperature at the electrode. This is not an electrosurgical diathermy system.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Storage Environment Humidity25 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature10 Degrees Celsius40 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+390558497943quality@fiab.it

Regulatory Flags#

DUNS number
439770017
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08054242441765NAU7951U79512020-04-12
08054242441772NAU7952U79522020-04-12
08054242441789NAU7955U79552020-04-12
08054242441796NAU7961U79612020-04-12
08054242441802NAU7750U77502020-04-12
08054242441819NAU7751U77512020-04-12
08054242441826NAU7752U77522020-04-12
08054242441833NAU7755U77552020-04-12
08054242441840NAU7761U77612020-04-12
08054242444933NAU7959U79592020-04-12
08054242441758NAU7950U79502020-04-12
08054751932464NAF7266F72662025-07-27
08033695726360NAF6738RAHAF6738RAHA2024-09-16
28058480756401NAF7244F72442024-09-05
28058480757415NAF7255F72552024-09-05
18033695727142NAF7244F72442020-05-14
18033695727159NAF7255F72552020-05-14
18033695727166NAF7277F72772020-05-14
08033695726414NAF6748RAHAF6748RAHA2023-10-09
08033003264676NAF6726P/NK33F6726P/NK332024-03-19

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00685447020677RFP-100A™ RF Puncture GeneratorBOSTON SCIENTIFIC CORPORATIONGEI2026-06-08
08800042706159Artisential Monopolar SpatulaLIVSMEDGEI2026-06-05
00840319759042Hayden MedicalHayden Medical, Inc.GEI2026-06-04
00840319759059Hayden MedicalHayden Medical, Inc.GEI2026-06-04
00840319759066Hayden MedicalHayden Medical, Inc.GEI2026-06-04
00840319759073Hayden MedicalHayden Medical, Inc.GEI2026-06-04
08809306764072VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764089VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764133VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764140VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764157VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764164VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764171VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
08809306764188VIVA RF ElectrodeSTARMED CO.,LTDGEI2026-06-04
00198506091261ELMED INCORPORATEDELMED INCORPORATEDGEI2026-06-03
00846338001209IEC BiPolar Cable, DisposableELLIQUENCE, LLCGEI2026-06-03
00846338001230Bipolar CableELLIQUENCE, LLCGEI2026-06-03
00846338001247Bipolar Cable - 2 Flat ProngsELLIQUENCE, LLCGEI2026-06-03
00846338001537Bipolar Cable - 2 Flat ProngsELLIQUENCE, LLCGEI2026-06-03
00846338001582IEC Power Cord 110vELLIQUENCE, LLCGEI2026-06-03
00846338001605IEC Power Cord 220v ANZ PlugELLIQUENCE, LLCGEI2026-06-03
00846338001612IEC Power Cord 220v EuropeELLIQUENCE, LLCGEI2026-06-03
00846338001629IEC Power Cord U.K. 220vELLIQUENCE, LLCGEI2026-06-03
00846338006044Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02
00846338006051Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02
00846338006068Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02
00846338006082Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02
00846338006099Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02
00846338006105Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02
00846338006112Empire MicroIncision ElectrodeELLIQUENCE, LLCGEI2026-06-02