OneTouch Ultra2
- Primary DI
- 20353885008857
- Brand
- OneTouch Ultra2
- Company
- LifeScan Europe GmbH
- Model
- 021-100
- Catalog number
- 021-100
- Device description
- OneTouch Ultra2 Blood Glucose Monitoring System with Delica Lancing Device, not for resale or reimbursement. Uses OneTouch Ultra Blue Test strip
- Published
- 2017-09-13
- Public version status
- Update
- Distribution status
- In Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
- Rx
- false
- OTC
- true
- Sterile
- false
- Single use
- false
Product Codes#
Code, Name table| Code | Name |
|---|
| CGA | GLUCOSE OXIDASE, GLUCOSE |
Product Code Classifications#
Code, Device, Specialty table| Code | Device | Specialty | Class |
|---|
| CGA | Glucose Oxidase, Glucose | Clinical Chemistry | 2 |
Identifiers And Packaging#
Identifier, Type, Agency table| Identifier | Type | Agency | Package quantity | Status |
|---|
| 20353885008857 | Package | GS1 | 10 | In Commercial Distribution |
| 00353885008853 | Primary | GS1 | 0 | |
| 53885-452-10 | Secondary | NDC/NHRIC | 0 | |
Alternate GTIN / UPC / EAN Codes
Source identifier, GTIN-14 normalized, UPC-A table| Source identifier | GTIN-14 normalized | UPC-A | EAN-13 |
|---|
| 20353885008857 | 20353885008857 | | |
| 00353885008853 | 00353885008853 | 353885008853 | 0353885008853 |
Device Sizes#
Type, Value, Unit table| Type | Value | Unit |
|---|
| Device Size Text, specify | 0 | |
| Device Size Text, specify | 0 | |
| Needle Gauge | 30 | Gauge |
Storage And Handling#
Type, Low, High table| Type | Low | High | Condition |
|---|
| Handling Environment Humidity | 10 Percent (%) Relative Humidity | 90 Percent (%) Relative Humidity | |
| Handling Environment Temperature | 43 Degrees Fahrenheit | 111 Degrees Fahrenheit | |
| Special Storage Condition, Specify | 0 | 0 | Do not refrigerate |
| Special Storage Condition, Specify | 0 | 0 | Operating Altitude up to 10000 Feet |
| Storage Environment Temperature | 0 | 86 Degrees Fahrenheit | |
Regulatory Flags#
- DUNS number
- 480240820
- Device count
- 1
- DM exempt
- false
- Premarket exempt
- false
- HCT/P
- false
- Kit
- true
- Combination product
- false
- Lot or batch
- true
- Serial number
- true
- Manufacturing date on label
- true
- Expiration date on label
- true
- Donation ID number
- false
- Contains natural rubber latex
- false
- No natural rubber latex
- false
- Sterilization required before use
- false
Other Devices From This Company#
Other Devices Sharing Product Codes#
Primary DI, Brand, Company table| Primary DI | Brand | Company | Product code | Published |
|---|
| 00384841518802 | Prodigy AutoCode Blood Glucose Monitoring System | Prodigy Diabetes Care, LLC | CGA | 2026-08-13 |
| 04719869706904 | Tyson Bio AC500 PRO Blood Glucose Monitoring System (Meter Only) (FDA) | TYSON BIORESEARCH INC. | CGA | 2026-07-13 |
| 04719869706911 | TysonBio AC500 PRO Blood Glucose Test Strips (50T) | TYSON BIORESEARCH INC. | CGA | 2026-07-13 |
| 04719869706942 | Tyson Bio AC500 PRO Control Solution (Level 1) (FDA) | TYSON BIORESEARCH INC. | CGA | 2026-07-13 |
| 04719869706959 | Tyson Bio AC500 PRO Control Solution (Level 3) (FDA) | TYSON BIORESEARCH INC. | CGA | 2026-07-13 |
| 05700693930978 | ABL90 FLEX | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700693930985 | ABL90 FLEX PLUS | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699446572 | SP90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699447579 | SP90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699461056 | SC90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699461087 | SC90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699461094 | SC90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699461100 | SC90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699461131 | SC90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| 05700699461605 | SC90 | Radiometer Medical ApS | CGA | 2026-07-09 |
| MHC1101665142 | EasyTouch | MHC MEDICAL PRODUCTS, LLC | CGA | 2026-01-07 |
| MHC18073002 | EasyTouch | MHC MEDICAL PRODUCTS, LLC | CGA | 2026-01-07 |
| 00311917064635 | Walgreens | WALGREEN CO. | CGA | 2025-06-20 |
| 00353885013000 | OneTouch Ultra | LifeScan U.S. LLC | CGA | 2025-06-20 |
| 00194346219254 | ReliOn™ Premier Blood Glucose Test Strips | WAL-MART STORES, INC. | CGA | 2025-02-11 |
| 00194346219261 | ReliOn™ Premier Blood Glucose Test Strips | WAL-MART STORES, INC. | CGA | 2025-02-11 |
| 00054749005710 | i-STAT G Cartridge | ABBOTT POINT OF CARE INC. | CGA | 2024-04-30 |
| MHC19902833042 | Members Mark | WAL-MART STORES, INC. | CGA | 2023-05-10 |
| MHC19902833062 | Members Mark | WAL-MART STORES, INC. | CGA | 2023-04-18 |
| MHC19902833072 | Members Mark | WAL-MART STORES, INC. | CGA | 2023-04-18 |
| 10385480631645 | Nova Primary | NOVA BIOMEDICAL CORPORATION | CGA | 2023-02-24 |
| 10385480631652 | Nova Primary | NOVA BIOMEDICAL CORPORATION | CGA | 2023-02-24 |
| 10385480631669 | Nova Primary | NOVA BIOMEDICAL CORPORATION | CGA | 2023-02-24 |
| 10385480632307 | Nova Primary | NOVA BIOMEDICAL CORPORATION | CGA | 2023-02-22 |
| 10673486000719 | TECO DIAGNOSTICS | TECO DIAGNOSTICS | CGA | 2022-08-09 |