EDGE

Primary DI
20653405988332
Brand
EDGE
Company
Conmed Corporation
Model
AES-50SP
Catalog number
AES-50SP
Device description
Edge Hip Probe, 50°, 18 cm
Published
2023-03-30
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
true
Sterile
true
Single use
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, cutting & coagulation & accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
20653405988332PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
2065340598833220653405988332

GMDN Terms#

Term, Definition table
TermDefinition
Endoscopic electrosurgical handpiece/electrode, bipolar, single-useA sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery, and may in addition be intended for open surgery; it is not intended for focal percutaneous ablation. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps, rigid probe with controls). This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00KEEP DRY
Storage Environment Humidity0 Percent (%) Relative Humidity90 Percent (%) Relative Humidity
Storage Environment Temperature-30 Degrees Celsius40 Degrees Celsius
Storage Environment Temperature-22 Degrees Fahrenheit104 Degrees Fahrenheit

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
+1(866)426-6633CustomerExperience@conmed.com

Regulatory Flags#

DUNS number
071595540
Device count
1
Lot or batch
true
Expiration date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10845854051399AirSealiAS8-dViAS8-dV2021-08-22
10845854084137AirSeal®iAS8-dVLiAS8-dVL2023-01-06
10845854013137QUICKLATCHQL4300QL43002020-12-10
10845854031841CONMEDT2531T25312020-12-10
10845854036204POWERPROPRO6185PRO61852023-09-01
20845854061807SnapEvacSNAPEVAC20SNAPEVAC202020-06-06
30653405011907EXCEL60-6050-00160-6050-0012016-09-24
30653405988346Argo KnotlessK55RTAPK55RTAP2023-01-13
30653405988360Argo KnotlessK475RTAPK475RTAP2023-01-13
10845854032619CROSSFTTFT-45MTFT-45M2021-01-19
10845854032633CROSSFTTFT-55MTFT-55M2021-01-19
10845854032657CROSSFTTFT-65MTFT-65M2021-01-19
10653405004646ELECTROLASE HYFRECATOR7-100-8BX7-100-8BX2016-09-24
10653405013785THERMOGARD7-3847-3842016-09-24
10845854650134THERMOGARD7-3827-3822022-09-21
20653405051906Precisor0008520008522016-09-24
20653405051920Precisor0008540008542016-09-24
30653405046800BiCap SuperconductorBP-10300ABP-10300A2016-09-24
30653405046992BiCap SuperconductorBP-7300ABP-7300A2016-09-24
30653405047005BiCap SuperconductorBP-5200ABP-5200A2016-09-24

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07613327693287MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693294MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693362MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693379MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693386MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693393MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693409MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693416MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693423MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693430MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693447MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693454MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693461MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693478MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693485MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693492MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693508MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693515MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693522MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693539MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693546MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693553MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693560MalisSTRYKER CORPORATIONGEI2026-02-25
07613327693577MalisSTRYKER CORPORATIONGEI2026-02-25
07613327556469NeptuneSTRYKER CORPORATIONGEI2025-01-30
07613327548204Neptune SafeAirSTRYKER CORPORATIONGEI2025-01-06
07613327556650NeptuneSTRYKER CORPORATIONGEI2024-12-13
07613327548129NeptuneSTRYKER CORPORATIONGEI2024-12-10
07613327548143NeptuneSTRYKER CORPORATIONGEI2024-12-10
07613327548167NeptuneSTRYKER CORPORATIONGEI2024-12-10